ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 ADC10D1000/ADC10D1500 Low Power, 10-Bit, Dual 1.0/1.5 GSPS or Single 2.0/3.0 GSPS ADC Check for Samples: ADC10D1000, ADC10D1500 FEATURES DESCRIPTION * * * The ADC10D1000/1500 is the latest advance in TI's Ultra-High-Speed ADC family. This low-power, highperformance CMOS analog-to-digital converter digitizes signals at 10-bit resolution for dual channels at sampling rates of up to 1.0/1.5 GSPS (Non-DES Mode) or for a single channel up to 2.0/3.0 GSPS (DES Mode). The ADC10D1000/1500 achieves excellent accuracy and dynamic performance while dissipating less than 2.8/3.6 Watts. The product is packaged in a leaded or lead-free 292-ball thermally enhanced BGA package over the rated industrial temperature range of -40C to +85C. 1 2 * * * * * * * * * * Excellent Accuracy and Dynamic Performance Pin Compatible with ADC12D1000/1600/1800 Low Power Consumption, Further Reduced at Lower Fs Internally Terminated, Buffered, Differential Analog Inputs R/W SPI Interface for Extended Control Mode Dual-Edge Sampling Mode, in Which the I- and Q-channels Sample One Input at Twice the Sampling Clock Rate Test Patterns at Output for System Debug Programmable 15-bit Gain and 12-bit Plus Sign Offset Programmable tAD Adjust Feature 1:1 Non-demuxed or 1:2 Demuxed LVDS Outputs AutoSync Feature for Multi-Chip Systems Single 1.9V 0.1V Power Supply 292-Ball BGA Package (27mm x 27mm x 2.4mm with 1.27mm Ball-Pitch); No Heat Sink Required APPLICATIONS * * * Wideband Communications Data Acquisition Systems Digital Oscilloscopes The ADC10D1000/1500 builds upon the features, architecture and functionality of the 8-bit GHz family of ADCs. An expanded feature set includes AutoSync for multi-chip synchronization, 15-bit programmable gain and 12-bit plus sign programmable offset adjustment for each channel. The improved internal track-and-hold amplifier and the extended selfcalibration scheme enable a very flat response of all dynamic parameters beyond Nyquist, producing 9.1/9.0 Effective Number of Bits (ENOB) with a 100 MHz input signal and a 1.0/1.5 GHz sample rate while providing a 10-18 Code Error Rate (CER) Dissipating a typical 2.77/3.59 Watts in NonDemultiplex Mode at 1.0/1.5 GSPS from a single 1.9V supply, this device is specified to have no missing codes over the full operating temperature range. Each channel has its own independent DDR Data Clock, DCLKI and DCLKQ, which are in phase when both channels are powered up, so that only one Data Clock could be used to capture all data, which is sent out at the same rate as the input sample clock. If the 1:2 Demux Mode is selected, a second 10-bit LVDS bus becomes active for each channel, such that the output data rate is sent out two times slower to relax data-capture timing requirements. The part can also be used as a single 2.0/3.0 GSPS ADC to sample one of the I or Q inputs. The output formatting can be programmed to be offset binary or two's complement and the Low Voltage Differential Signaling (LVDS) digital outputs are compatible with IEEE 1596.3-1996, with the exception of an adjustable common mode voltage between 0.8V and 1.2V to allow for power reduction for well-controlled back planes. 1 2 Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. All trademarks are the property of their respective owners. PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of the Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. Copyright (c) 2008-2013, Texas Instruments Incorporated ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates. Table 1. Key Specifications (Non-Demux Non-DES Mode, Fs=1.0/1.5 GSPS, Fin = 100 MHz) Resolution 10 Bits Conversion Rate Dual channels at 1.0/1.5 GSPS (typ) Single channel at 2.0/3.0 GSPS (typ) Code Error Rate 10-18/10-18 (typ) ENOB 9.1/9.0 bits (typ) SNR 57/56.8 dB (typ) SFDR 70/68 dBc (typ) Full Power Bandwidth 2.8/2.8 GHz (typ) DNL 0.25/0.25 LSB (typ) Power Consumption Single Channel Enabled 1.61/1.92 W (typ) Dual Channels Enabled 2.77/3.59 W (typ) Power Down Mode 6/6 mW (typ) Table 2. Ordering Information (1) (2) (1) (2) 2 Industrial Temperature Range (-40C < TA < 85C) Package ADC10D1000/1500CIUT/NOPB Lead-free 292-Ball BGA Thermally Enhanced Package ADC10D1000/1500CIUT Leaded 292-Ball BGA Thermally Enhanced Package ADC10D1000/1500RB Reference Board For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI website at www.ti.com. If Military/Aerospace specified devices are required, please contact the TI Sales Office/Distributors for availability and specifications. IBIS models are available at www.ti.com Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Block Diagram 10 VinI+ 10 Rterm T/H 10- Bit ADC DI(9:0) 1:2 Demux 10 DId(9:0) VinI- DCLKI M ORI RCOut1 Output RCOut2 Buffers ORQ Clock Management and AutoSync U X DCLKQ 10 VinQ+ 10 Rterm T/H 10- Bit ADC DQ(9:0) 1:2 Demux 10 DQd(9:0) VinQCLK+ Rterm Control/Status and Other Logic CLKRCLK+ Rterm Control Pins SPI RCLK- Figure 1. Simplified Block Diagram Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 3 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Connection Diagram 1 2 3 4 5 6 7 8 A GND V_A SDO TPM NDM V_A GND V_E B Vbg GND ECEb SDI CalRun V_A GND GND_E C Rtrim+ Vcmo Rext+ SCSb SCLK V_A NC V_E D DNC Rtrim- Rext- GND GND CAL DNC V_A E V_A Tdiode+ DNC F V_A GND _TC G V_TC H 11 12 13 14 15 16 17 18 19 20 V_DR DId1+ GND_ DR DId4+ V_DR DId7+ GND_ DR DId9+ DId9- GND_ DR A RSV0- DId0+ DId1- DId3+ DId4- DId6+ DId7- DId8+ RSV2+ RSV3+ RSV3- B GND_E RSV1+ DId0- DId2+ DId3- DId5+ DId6- DId8- RSV2- V_DR DI0+ DI0- C V_DR DId2- GND_ DR DId5- V_DR GND_ DR V_DR DI1+ DI2+ DI2- D GND GND_ DR DI1- DI3+ DI3- E Tdiode- DNC GND_ DR DI4+ DI4- GND_ DR F GND _TC V_TC V_TC DI5+ DI5- DI6+ DI6- G VinI+ V_TC GND _TC V_A GND GND GND GND GND GND DI7+ DI7- DI8+ DI8- H J VinI- GND _TC V_TC VbiasI GND GND GND GND GND GND V_DR DI9+ DI9- V_DR J K GND VbiasI V_TC GND _TC GND GND GND GND GND GND ORI+ ORI- DCLK _I+ L GND VbiasQ V_TC GND _TC GND GND GND GND GND GND ORQ+ ORQ- DCLK _Q+ DCLK _Q- L M VinQ- GND _TC V_TC VbiasQ GND GND GND GND GND GND GND_ DR DQ9+ DQ9- GND_ DR M N VinQ+ V_TC GND _TC V_A GND GND GND GND GND GND DQ7+ DQ7- DQ8+ DQ8- N P V_TC GND _TC V_TC V_TC DQ5+ DQ5- DQ6+ DQ6- P R V_A GND _TC V_TC V_TC V_DR DQ4+ DQ4- V_DR R T V_A GND _TC GND _TC GND V_DR DQ1- DQ3+ DQ3- T U GND _TC CLK+ PDI GND GND RCOut _1- DNC V_A V CLK- DCLK _RST+ PDQ CalDly DES RCOut _2+ RCOut _2- V_E W DCLK _RST- GND DNC DDRPh RCLK- V_A GND GND_E Y GND V_A FSR RCLK+ RCOut _1+ V_A GND V_E 1 2 3 4 6 7 8 5 9 10 GND_E RSV0+ V_E V_A RSV1- DCLK _I- K RSV7- V_DR DQd2- GND_ DR DQd5- V_DR V_DR GND_ DR DQ1+ DQ2+ DQ2- U GND_E RSV7+ DQd0- DQd2+ DQd3- DQd5+ DQd6- DQd8- RSV4- GND_ DR DQ0+ DQ0- V DQd0+ DQd1- DQd3+ DQd4- DQd6+ DQd7- DQd8+ RSV4+ RSV5+ RSV5- W V_DR DQd1+ GND_ DR DQd4+ V_DR DQd7+ GND_ DR DQd9+ DQd9- GND_ DR Y 11 12 13 14 15 16 17 18 19 20 V_A V_E RSV6- GND_E RSV6+ 9 10 Figure 2. ADC10D1000/1500 Connection Diagram NOTE The center ground pins are for thermal dissipation and must be soldered to a ground plane to ensure rated performance. See SUPPLY/GROUNDING, LAYOUT AND THERMAL RECOMMENDATIONS for more information. 4 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Ball Descriptions and Equivalent Circuits Table 3. Analog Front-End and Clock Balls Ball No. Name Equivalent Circuit Description VA 50k AGND H1/J1 N1/M1 VinI+/VinQ+/- VCMO 100 Control from VCMO VA 50k AGND Differential signal I- and Q-inputs. In the Non-Dual Edge Sampling (Non-DES) Mode, each I- and Qinput is sampled and converted by its respective channel with each positive transition of the CLK input. In Non-ECM (Non-Extended Control Mode) and DES Mode, both channels sample the I-input. In Extended Control Mode (ECM), the Q-input may optionally be selected for conversion in DES Mode by the DEQ Bit (Addr: 0h, Bit 6). Each I- and Q-channel input has an internal common mode bias that is disabled when DCcoupled Mode is selected. Both inputs must be either AC- or DC-coupled. The coupling mode is selected by the VCMO Pin. In Non-ECM, the full-scale range of these inputs is determined by the FSR Pin; both I- and Qchannels have the same full-scale input range. In ECM, the full-scale input range of the I- and Qchannel inputs may be independently set via the Control Register (Addr: 3h and Addr: Bh). Note that the high and low full-scale input range setting in Non-ECM corresponds to the mid and minimum full-scale input range in ECM. The input offset may also be adjusted in ECM. VA U2/V1 50k AGND CLK+/- VA 100 VBIAS 50k Differential Converter Sampling Clock. In the NonDES Mode, the analog inputs are sampled on the positive transitions of this clock signal. In the DES Mode, the selected input is sampled on both transitions of this clock. This clock must be ACcoupled. AGND VA AGND V2/W1 DCLK_RST+/- 100 VA Differential DCLK Reset. A positive pulse on this input is used to reset the DCLKI and DCLKQ outputs of two or more ADC10D1000/1500s in order to synchronize them with other ADC10D1000/1500s in the system. DCLKI and DCLKQ are always in phase with each other, unless one channel is powered down, and do not require a pulse from DCLK_RST to become synchronized. The pulse applied here must meet timing relationships with respect to the CLK input. Although supported, this feature has been superseded by AutoSync. AGND Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 5 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Table 3. Analog Front-End and Clock Balls (continued) Ball No. Name Equivalent Circuit Description VA VCMO C2 200k VCMO Enable AC Coupling 8 pF GND VA B1 Common Mode Voltage Output or Signal Coupling Select. If AC-coupled operation at the analog inputs is desired, this pin should be held at logiclow level. This pin is capable of sourcing/ sinking up to 100 A. For DC-coupled operation, this pin should be left floating or terminated into highimpedance. In DC-coupled Mode, this pin provides an output voltage which is the optimal commonmode voltage for the input signal and should be used to set the common-mode voltage of the driving buffer. Bandgap Voltage Output or LVDS Common-mode Voltage Select. This pin provides a buffered version of the bandgap output voltage and is capable of sourcing/sinking 100 uA and driving a load of up to 80 pF. Alternately, this pin may be used to select the LVDS digital output commonmode voltage. If tied to logic-high, the 1.2V LVDS common-mode voltage is selected; 0.8V is the default. VBG GND VA C3/D3 Rext+/- V External Reference Resistor terminals. A 3.3 k 0.1% resistor should be connected between Rext+/-. The Rext resistor is used as a reference to trim internal circuits which affect the linearity of the converter; the value and precision of this resistor should not be compromised. V Input Termination Trim Resistor terminals. A 3.3 k 0.1% resistor should be connected between Rtrim+/-. The Rtrim resistor is used to establish the calibrated 100 input impedance of VinI, VinQ and CLK. These impedances may be fine tuned by varying the value of the resistor by a corresponding percentage; however, the tuning range and performance is not specified for such an alternate value. GND VA C1/D2 Rtrim+/- GND VA Tdiode_P E2/F3 GND Tdiode+/- VA Temperature Sensor Diode Positive (Anode) and Negative (Cathode) Terminals. This set of pins is used for die temperature measurements. It has not been fully characterized. Tdiode_N GND 6 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Table 3. Analog Front-End and Clock Balls (continued) Ball No. Name Equivalent Circuit Description VA Y4/W5 50k AGND RCLK+/- 100 VA VBIAS 50k Reference Clock Input. When the AutoSync feature is active, and the ADC10D1000/1500 is in Slave Mode, the internal divided clocks are synchronized with respect to this input clock. The delay on this clock may be adjusted when synchronizing multiple ADCs. This feature is available in ECM via Control Register (Addr: Eh). AGND VA 100: Y5/U6 V6/V7 100: RCOut1+/RCOut2+/- + Reference Clock Output 1 and 2. These signals provide a reference clock at a rate of CLK/4, when enabled, independently of whether the ADC is in Master or Slave Mode. They are used to drive the RCLK of another ADC10D1000/1500, to enable automatic synchronization for multiple ADCs (AutoSync feature). The impedance of each trace from RCOut1 and RCOut2 to the RCLK of another ADC10D1000/1500 should be 100 differential. Having two clock outputs allows the autosynchronization to propagate as a binary tree. Use the DOC Bit (Addr: Eh, Bit 1) to enable/ disable this feature; default is disabled. A GND Table 4. Control and Status Balls Ball No. Name Equivalent Circuit VA V5 DES GND Description Dual Edge Sampling (DES) Mode select. In the Non-Extended Control Mode (Non-ECM), when this input is set to logic-high, the DES Mode of operation is selected, meaning that the VinI input is sampled by both channels in a time-interleaved manner. The VinQ input is ignored. When this input is set to logic-low, the device is in Non-DES Mode, i.e. the I- and Q-channels operate independently. In the Extended Control Mode (ECM), this input is ignored and DES Mode selection is controlled through the Control Register by the DES Bit (Addr: 0h, Bit 7); default is NonDES Mode operation. VA V4 Calibration Delay select. By setting this input logichigh or logic-low, the user can select the device to wait a longer or shorter amount of time, respectively, before the automatic power-on selfcalibration is initiated. This feature is pin-controlled only and is always active during ECM and NonECM. CalDly GND Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 7 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Table 4. Control and Status Balls (continued) Ball No. Name Equivalent Circuit VA D6 CAL GND Description Calibration cycle initiate. The user can command the device to execute a self-calibration cycle by holding this input high a minimum of tCAL_H after having held it low a minimum of tCAL_L. If this input is held high at the time of power-on, the automatic power-on calibration cycle is inhibited until this input is cycled low-then-high. This pin is active in both ECM and Non-ECM. In ECM, this pin is logically OR'd with the CAL Bit (Addr: 0h, Bit 15) in the Control Register. Therefore, both pin and bit must be set low and then either can be set high to execute an on-command calibration. VA B5 Calibration Running indication. This output is logic-high while the calibration sequence is executing. This output is logic-low otherwise. CalRun GND VA 50 k: U3 V3 PDI PDQ GND Power Down I- and Q-channel. Setting either input to logic-high powers down the respective I- or Qchannel. Setting either input to logic-low brings the respective I- or Q-channel to a operational state after a finite time delay. This pin is active in both ECM and Non-ECM. In ECM, each Pin is logically OR'd with its respective Bit. Therefore, either this pin or the PDI and PDQ Bit in the Control Register can be used to power-down the I- and Q-channel (Addr: 0h, Bit 11 and Bit 10), respectively. VA A4 Test Pattern Mode select. With this input at logichigh, the device continuously outputs a fixed, repetitive test pattern at the digital outputs. In the ECM, this input is ignored and the Test Pattern Mode can only be activated through the Control Register by the TPM Bit (Addr: 0h, Bit 12). TPM GND VA A5 Non-Demuxed Mode select. Setting this input to logic-high causes the digital output bus to be in the 1:1 Non-Demuxed Mode. Setting this input to logic-low causes the digital output bus to be in the 1:2 Demuxed Mode. This feature is pin-controlled only and remains active during ECM and NonECM. NDM GND 8 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Table 4. Control and Status Balls (continued) Ball No. Name Equivalent Circuit VA Y3 FSR GND VA W4 DDRPh GND Description Full-Scale input Range select. In Non-ECM, when this input is set to logic-low or logic-high, the fullscale differential input range for both I- and Qchannel inputs is set to the lower or higher FSR value, respectively. In the ECM, this input is ignored and the full-scale range of the I- and Qchannel inputs is independently determined by the setting of Addr: 3h and Addr: Bh, respectively. Note that the high (lower) FSR value in Non-ECM corresponds to the mid (min) available selection in ECM; the FSR range in ECM is greater. DDR Phase select. This input, when logic-low, selects the 0 Data-to-DCLK phase relationship. When logic-high, it selects the 90 Data-to-DCLK phase relationship, i.e. the DCLK transition indicates the middle of the valid data outputs. This pin only has an effect when the chip is in 1:2 Demuxed Mode, i.e. the NDM pin is set to logiclow. In ECM, this input is ignored and the DDR phase is selected through the Control Register by the DPS Bit (Addr: 0h, Bit 14); the default is 0 Mode. VA 50 k: B3 ECE Extended Control Enable bar. Extended feature control through the SPI interface is enabled when this signal is asserted (logic-low). In this case, most of the direct control pins have no effect. When this signal is de-asserted (logic-high), the SPI interface is disabled, all SPI registers are reset to their default values, and all available settings are controlled via the control pins. GND VA 100 k: C4 SCS Serial Chip Select bar. In ECM, when this signal is asserted (logic-low), SCLK is used to clock in serial data which is present on SDI and to source serial data on SDO. When this signal is deasserted (logic-high), SDI is ignored and SDO is in tri-stated. GND VA 100 k: C5 SCLK Serial Clock. In ECM, serial data is shifted into and out of the device synchronously to this clock signal. This clock may be disabled and held logiclow, as long as timing specifications are not violated when the clock is enabled or disabled. GND Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 9 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Table 4. Control and Status Balls (continued) Ball No. Name Equivalent Circuit Description VA 100 k: B4 Serial Data-In. In ECM, serial data is shifted into the device on this pin while SCS signal is asserted (logic-low). SDI GND VA A3 Serial Data-Out. In ECM, serial data is shifted out of the device on this pin while SCS signal is asserted (logic-low). This output is tri-stated when SCS is de-asserted. SDO GND D1, D7, E3, F4, W3, U7 DNC NONE Do Not Connect. These pins are used for internal purposes and should not be connected, i.e. left floating. Do not ground. C7 NC NONE Not Connected. This pin is not bonded and may be left floating or connected to any potential. Table 5. Power and Ground Balls Ball No. Name Equivalent Circuit A2, A6, B6, C6, D8, D9, E1, F1, H4, N4, R1, T1, U8, U9, W6, Y2, Y6 VA NONE Power Supply for the Analog circuitry. This supply is tied to the ESD ring. Therefore, it must be powered up before or with any other supply. G1, G3, G4, H2, J3, K3, L3, M3, N2, P1, P3, P4, R3, R4 VTC NONE Power Supply for the Track-and-Hold and Clock circuitry. A11, A15, C18, D11, D15, D17, J17, J20, R17, R20, T17, U11, U15, U16, Y11, Y15 VDR NONE Power Supply for the Output Drivers. A8, B9, C8, V8, W9, Y8 VE NONE Power Supply for the Digital Encoder. NONE Bias Voltage I-channel. This is an externally decoupled bias voltage for the I-channel. Each pin should individually be decoupled with a 100 nF capacitor via a low resistance, low inductance path to GND. NONE Bias Voltage Q-channel. This is an externally decoupled bias voltage for the Q-channel. Each pin should individually be decoupled with a 100 nF capacitor via a low resistance, low inductance path to GND. J4, K2 L2, M4 10 VbiasI VbiasQ Submit Documentation Feedback Description Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Table 5. Power and Ground Balls (continued) Ball No. Name Equivalent Circuit A1, A7, B2, B7, D4, D5, E4, K1, L1, T4, U4, U5, W2, W7, Y1, Y7, H8:N13 Description GND NONE Ground Return for the Analog circuitry. F2, G2, H3, J2, K4, L4, M2, N3, P2, R2, T2, T3, U1 GNDTC NONE Ground Return for the Track-and-Hold and Clock circuitry. A13, A17, A20, D13, D16, E17, F17, F20, M17, M20, U13, U17, V18, Y13, Y17, Y20 GNDDR NONE Ground Return for the Output Drivers. A9, B8, C9, V9, W8, Y9 GNDE NONE Ground Return for the Digital Encoder. Table 6. High-Speed Digital Outputs Ball No. Name Equivalent Circuit Description VDR K19/K20 L19/L20 DCLKI+/DCLKQ+/- - + + - Data Clock Output for the I- and Q-channel data bus. These differential clock outputs are used to latch the output data and, if used, should always be terminated with a 100 differential resistor placed as closely as possible to the differential receiver. Delayed and non-delayed data outputs are supplied synchronously to this signal. In 1:2 Demux Mode or Non-Demux Mode, this signal is at 1/4 or 1/2 the sampling clock rate, respectively. DCLKI and DCLKQ are always in phase with each other, unless one channel is powered down, and do not require a pulse from DCLK_RST to become synchronized. DR GND VDR K17/K18 L17/L18 ORI+/ORQ+/- - + + - Out-of-Range Output for the I- and Q-channel. This differential output is asserted logic-high while the over- or under-range condition exists, i.e. the differential signal at each respective analog input exceeds the full-scale value. Each OR result refers to the current Data, with which it is clocked out. If used, each of these outputs should always be terminated with a 100 differential resistor placed as closely as possible to the differential receiver. DR GND Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 11 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Table 6. High-Speed Digital Outputs (continued) 12 Ball No. Name J18/J19 H19/H20 H17/H18 G19/G20 G17/G18 F18/F19 E19/E20 D19/D20 D18/E18 C19/C20 * M18/M19 N19/N20 N17/N18 P19/P20 P17/P18 R18/R19 T19/T20 U19/U20 U18/T18 V19/V20 DI9+/DI8+/DI7+/DI6+/DI5+/DI4+/DI3+/DI2+/DI1+/DI0+/* DQ9+/DQ8+/DQ7+/DQ6+/DQ5+/DQ4+/DQ3+/DQ2+/DQ1+/DQ0+/- A18/A19 B17/C16 A16/B16 B15/C15 C14/D14 A14/B14 B13/C13 C12/D12 A12/B12 B11/C11 * Y18/Y19 W17/V16 Y16/W16 W15/V15 V14/U14 Y14/W14 W13/V13 V12/U12 Y12/W12 W11/V11 DId9+/DId8+/DId7+/DId6+/DId5+/DId4+/DId3+/DId2+/DId1+/DId0+/* DQd9+/DQd8+/DQd7+/DQd6+/DQd5+/DQd4+/DQd3+/DQd2+/DQd1+/DQd0+/- V10/U10 Y10/W10 W19/W20 W18/V17 B19/B20 B18/C17 C10/D10 A10/B10 RSV7+/RSV6+/RSV5+/RSV4+/RSV3+/RSV2+/RSV1+/RSV0+/- Submit Documentation Feedback Equivalent Circuit Description VDR - + + - I- and Q-channel Digital Data Outputs. In NonDemux Mode, this LVDS data is transmitted at the sampling clock rate. In Demux Mode, these outputs provide 1/2 the data at 1/2 the sampling clock rate, synchronized with the delayed data, i.e. the other 1/2 of the data which was sampled one clock cycle earlier. Compared with the DId and DQd outputs, these outputs represent the later time samples. If used, each of these outputs should always be terminated with a 100 differential resistor placed as closely as possible to the differential receiver. DR GND VDR - + + - Delayed I- and Q-channel Digital Data Outputs. In Non-Demux Mode, these outputs are tri-stated. In Demux Mode, these outputs provide 1/2 the data at 1/2 the sampling clock rate, synchronized with the non-delayed data, i.e. the other 1/2 of the data which was sampled one clock cycle later. Compared with the DI and DQ outputs, these outputs represent the earlier time samples. If used, each of these outputs should always be terminated with a 100 differential resistor placed as closely as possible to the differential receiver. DR GND NONE Reserved. These pins are used for internal purposes. They may be left unconnected and floating or connected as recommended in Terminating RSV Pins. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Absolute Maximum Ratings See notes (1) (2) Supply Voltage (VA, VTC, VDR, VE) 2.2V Supply Difference max(VA/TC/DR/E)min(VA/TC/DR/E) 0V to 100 mV -0.15V to (VA + 0.15V) Voltage on Any Input Pin (except VIN+/-) VIN+/- Voltage Range -0.15V to 2.5V Ground Difference max(GNDTC/DR/E) -min(GNDTC/DR/E) Input Current at Any Pin 0V to 100 mV (3) 50 mA ADC10D1000 Package Power Dissipation at TA 85C (3) 3.7 W ADC10D1500 Package Power Dissipation at TA 70C (3) 4.4 W ESD Susceptibility (4) Human Body Model Charged Device Model Machine Model 2500V 750V 250V -65C to +150C Storage Temperature (1) (2) (3) (4) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. There is no assurance of operation at the Absolute Maximum Ratings. For specifications and test conditions, see the Electrical Characteristics. The specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test conditions. All voltages are measured with respect to GND = GNDTC = GNDDR = GNDE = 0V, unless otherwise specified. When the input voltage at any pin exceeds the power supply limits, i.e. less than GND or greater than VA, the current at that pin should be limited to 50 mA. In addition, over-voltage at a pin must adhere to the maximum voltage limits. Simultaneous over-voltage at multiple pins requires adherence to the maximum package power dissipation limits. These dissipation limits are calculated using JEDEC JESD51-7 thermal model. Higher dissipation may be possible based on specific customer thermal situation and specified package thermal resistances from junction to case. Human body model is 100 pF capacitor discharged through a 1.5 k resistor. Machine model is 220 pF discharged through 0. Charged device model simulates a pin slowly acquiring charge (such as from a device sliding down the feeder in an automated assembler) then rapidly being discharged. Operating Ratings See notes (1) (2) Ambient Temperature Range ADC10D1000 -40C TA +85C ADC10D1500 (Standard JEDEC thermal model) -40C TA +70C ADC10D1500 (Enhanced thermal model/heatsink) -40C TA +85C Junction Temperature Range TJ +138C Supply Voltage (VA, VTC, VE) +1.8V to +2.0V Driver Supply Voltage (VDR) +1.8V to VA VIN+/- Voltage Range (Maintaining Common Mode) 0V to 2.15V (100% duty cycle) 0V to 2.5V (10% duty cycle) Ground Difference max(GNDTC/DR/E) -min(GNDTC/DR/E) 0V CLK+/- Voltage Range 0V to VA Differential CLK Amplitude 0.4VP-P to 2.0VP-P Common Mode Input Voltage (1) (2) VCMO - 150mV < VCMI < VCMO +150mV Operating Ratings indicate conditions for which the device is functional, but do not ensure specific performance limits. For specifications and test conditions, see the Electrical Characteristics. The specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test conditions. All voltages are measured with respect to GND = GNDTC = GNDDR = GNDE = 0V, unless otherwise specified. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 13 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Package Thermal Resistance Package JA JC1 JC2 292-Ball BGA Thermally Enhanced Package 16C/W 2.9C/W 2.5C/W Converter Electrical Characteristics - Static Converter Characteristics The following specifications apply after calibration for VA = VDR = VTC = VE = +1.9V; I- and Q-channels, AC-coupled, unused channel terminated to AC ground, FSR Pin = High; CL = 10 pF; Differential, AC coupled Sine Wave Sampling Clock, fCLK = 1.0/1.5 GHz at 0.5 VP-P with 50% duty cycle (as specified); VBG = Floating; Non-Extended Control Mode; Rext = Rtrim = 3300 0.1%; Analog Signal Source Impedance = 100 Differential; 1:2 Demultiplex Non-DES Mode; Duty Cycle Stabilizer on. Boldface limits apply for TA = TMIN to TMAX. All other limits TA = 25C, unless otherwise noted. (1) (2) (3) (4) _ Symbol Parameter Conditions ADC10D1000 ADC10D1500 Typ Typ Resolution with No Missing Codes Lim 10 Lim Units (Limits) 10 bits INL Integral Non-Linearity (Best fit) 1 MHz DC-coupled over-ranged sine wave 0.65 1.4 0.65 1.4 LSB (max) DNL Differential Non-Linearity 1 MHz DC-coupled over-ranged sine wave 0.25 0.5 0.25 0.55 LSB (max) VOFF Offset Error VOFF_ADJ Input Offset Adjustment Range PFSE Positive Full-Scale Error (5) NFSE Negative Full-Scale Error (5) -2 Out-of-Range Output Code (1) (6) Extended Control Mode -2 45 LSB 45 25 mV 25 mV (max) mV (max) 25 25 (VIN+) - (VIN-) > + Full Scale 1023 1023 (VIN+) - (VIN-) < - Full Scale 0 0 The analog inputs, labeled "I/O", are protected as shown below. Input voltage magnitudes beyond the Absolute Maximum Ratings may damage this device. V A TO INTERNAL CIRCUITRY I/O GND (2) (3) (4) (5) (6) 14 To specify accuracy, it is required that VA, VTC, VE and VDR be well-bypassed. Each supply pin must be decoupled with separate bypass capacitors. Typical figures are at TA = 25C, and represent most likely parametric norms. Test limits are specified to AOQL (Average Outgoing Quality Level). The maximum clock frequency for Non-Demux Mode is tested up to 1.0 GHz for both the ADC10D1000 and the ADC10D1500 and specified by design and characterization up to 1.5 GHz for the ADC10D1500. Calculation of Full-Scale Error for this device assumes that the actual reference voltage is exactly its nominal value. Full-Scale Error for this device, therefore, is a combination of Full-Scale Error and Reference Voltage Error. See Figure 4. For relationship between Gain Error and Full-Scale Error, see Specification Definitions for Gain Error. This parameter is specified by design and is not tested in production. Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Converter Electrical Characteristics - Dynamic Converter Characteristics The following specifications apply after calibration for VA = VDR = VTC = VE = +1.9V; I- and Q-channels, AC-coupled, unused channel terminated to AC ground, FSR Pin = High; CL = 10 pF; Differential, AC coupled Sine Wave Sampling Clock, fCLK = 1.0/1.5 GHz at 0.5 VP-P with 50% duty cycle (as specified); VBG = Floating; Non-Extended Control Mode; Rext = Rtrim = 3300 0.1%; Analog Signal Source Impedance = 100 Differential; 1:2 Demultiplex Non-DES Mode; Duty Cycle Stabilizer on. Boldface limits apply for TA = TMIN to TMAX. All other limits TA = 25C, unless otherwise noted. (1) (2) (3) (4) _ Symbol FPBW Parameter Conditions Full Power Bandwidth Gain Flatness CER Code Error Rate NPR Noise Power Ratio ADC10D1000 ADC10D1500 Typ Typ Lim Lim Units (Limits) Non-DES Mode 2.8 2.8 GHz DES Mode 1.25 1.25 GHz DESIQ Mode 1.75 1.75 GHz D.C. to Fs/2 0.35 0.4 dBFS D.C. to Fs 0.5 1.2 -18 -18 10 dBFS Error/Sam ple 10 fc,notch = 325 MHz, Notch width = 5% 48 48 dB AIN = 100 MHz @ -0.5 dBFS 9.1 9.0 bits AIN = 248 MHz @ -0.5 dBFS 9.1 1:2 Demux Non-DES Mode ENOB Effective Number of Bits 8.3 AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS 8.8 9.0 Signal-to-Noise Plus Distortion Ratio 56.5 AIN = 248 MHz @ -0.5 dBFS 56.5 52 56 52 AIN = 373 MHz @ -0.5 dBFS Signal-to-Noise Ratio AIN = 100 MHz @ -0.5 dBFS 57 AIN = 248 MHz @ -0.5 dBFS 57 52.7 AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS 56.5 bits 56.1 dB 55.6 dB (min) 48.4 dB (min) dB (min) 54.5 dB 56.8 dB 56.4 56.4 AIN = 748 MHz @ -0.5 dBFS (1) bits (min) 54.9 AIN = 748 MHz @ -0.5 dBFS SNR bits (min) 8.8 AIN = 100 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS bits (min) 7.8 8.3 AIN = 748 MHz @ -0.5 dBFS SINAD 8.9 52.7 dB (min) 50 dB (min) dB (min) 55 dB The analog inputs, labeled "I/O", are protected as shown below. Input voltage magnitudes beyond the Absolute Maximum Ratings may damage this device. V A TO INTERNAL CIRCUITRY I/O GND (2) (3) (4) To specify accuracy, it is required that VA, VTC, VE and VDR be well-bypassed. Each supply pin must be decoupled with separate bypass capacitors. Typical figures are at TA = 25C, and represent most likely parametric norms. Test limits are specified to AOQL (Average Outgoing Quality Level). The maximum clock frequency for Non-Demux Mode is tested up to 1.0 GHz for both the ADC10D1000 and the ADC10D1500 and specified by design and characterization up to 1.5 GHz for the ADC10D1500. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 15 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Converter Electrical Characteristics - Dynamic Converter Characteristics (continued) The following specifications apply after calibration for VA = VDR = VTC = VE = +1.9V; I- and Q-channels, AC-coupled, unused channel terminated to AC ground, FSR Pin = High; CL = 10 pF; Differential, AC coupled Sine Wave Sampling Clock, fCLK = 1.0/1.5 GHz at 0.5 VP-P with 50% duty cycle (as specified); VBG = Floating; Non-Extended Control Mode; Rext = Rtrim = 3300 0.1%; Analog Signal Source Impedance = 100 Differential; 1:2 Demultiplex Non-DES Mode; Duty Cycle Stabilizer on. Boldface limits apply for TA = TMIN to TMAX. All other limits TA = 25C, unless otherwise noted. (1) (2) (3) (4) _ Symbol THD Parameter Conditions Total Harmonic Distortion ADC10D1000 ADC10D1500 Typ Typ Lim AIN = 100 MHz @ -0.5 dBFS -67 AIN = 248 MHz @ -0.5 dBFS -69 -60 -66 -60 AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS Second Harmonic Distortion dB AIN = 248 MHz @ -0.5 dBFS -71 -71 dBc -71 dBc -71 dBc -70 dBc AIN = 100 MHz @ -0.5 dBFS -70 -68 dBc AIN = 248 MHz @ -0.5 dBFS -70 -72 dBc -63 dBc -69 dBc AIN = 748 MHz @ -0.5 dBFS -65 AIN = 100 MHz @ -0.5 dBFS 70 AIN = 248 MHz @ -0.5 dBFS 66 57.9 66 57.9 AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS dBc 68 dBc 68 dBc (min) 63 AIN = 748 MHz @ -0.5 dBFS ENOB dB (max) dBc AIN = 498 MHz @ -0.5 dBFS Non-Demux Non-DES Mode 54 dBc (4) Effective Number of Bits AIN = 100 MHz @ -0.5 dBFS 9.1 AIN = 248 MHz @ -0.5 dBFS 9.1 AIN = 498 MHz @ -0.5 dBFS 8.4 9.1 bits 9.1 bits (min) 8.8 9.0 8.3 7.8 9.0 Signal-to-Noise Plus Distortion Ratio bits AIN = 100 MHz @ -0.5 dBFS 56.6 AIN = 248 MHz @ -0.5 dBFS 56.5 56.5 52.6 AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS 56.5 54.5 56 52.0 dB dB (min) 48.4 56 dB AIN = 100 MHz @ -0.5 dBFS 57 AIN = 248 MHz @ -0.5 dBFS 57 53.5 AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS 57 dB 57 dB (min) 55.5 56.5 52.7 50 56.5 Total Harmonic Distortion dB AIN = 100 MHz @ -0.5 dBFS -67 AIN = 248 MHz @ -0.5 dBFS -66 -67 -60 -66 AIN = 748 MHz @ -0.5 dBFS 16 Submit Documentation Feedback -60 dB -66 -60 AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS dB (min) dB (min) AIN = 748 MHz @ -0.5 dBFS THD dB (min) dB (min) AIN = 748 MHz @ -0.5 dBFS Signal-to-Noise Ratio bits (min) bits (min) AIN = 748 MHz @ -0.5 dBFS SNR dBc (min) dBc (min) 65 AIN = 373 MHz @ -0.5 dBFS SINAD dB (max) -76 AIN = 373 MHz @ -0.5 dBFS Spurious-Free Dynamic Range -53.6 -63 AIN = 748 MHz @ -0.5 dBFS SFDR dB (max) -76 AIN = 498 MHz @ -0.5 dBFS Third Harmonic Distortion dB -63 AIN = 100 MHz @ -0.5 dBFS AIN = 373 MHz @ -0.5 dBFS 3rd Harm Units (Limits) -65 -60 AIN = 748 MHz @ -0.5 dBFS 2nd Harm Lim -66 dB (max) -53.6 dB (max) dB (max) dB Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Converter Electrical Characteristics - Dynamic Converter Characteristics (continued) The following specifications apply after calibration for VA = VDR = VTC = VE = +1.9V; I- and Q-channels, AC-coupled, unused channel terminated to AC ground, FSR Pin = High; CL = 10 pF; Differential, AC coupled Sine Wave Sampling Clock, fCLK = 1.0/1.5 GHz at 0.5 VP-P with 50% duty cycle (as specified); VBG = Floating; Non-Extended Control Mode; Rext = Rtrim = 3300 0.1%; Analog Signal Source Impedance = 100 Differential; 1:2 Demultiplex Non-DES Mode; Duty Cycle Stabilizer on. Boldface limits apply for TA = TMIN to TMAX. All other limits TA = 25C, unless otherwise noted. (1) (2) (3) (4) _ Symbol 2nd Harm Parameter Conditions Second Harmonic Distortion ADC10D1000 ADC10D1500 Typ Typ Lim Lim Units (Limits) AIN = 100 MHz @ -0.5 dBFS -85 -85 dBc AIN = 248 MHz @ -0.5 dBFS -71 -71 dBc -71 -71 AIN = 100 MHz @ -0.5 dBFS -68 -68 dBc AIN = 248 MHz @ -0.5 dBFS -70 -70 dBc -70 -70 AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS dBc dBc AIN = 748 MHz @ -0.5 dBFS 3rd Harm Third Harmonic Distortion dBc AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS dBc dBc AIN = 748 MHz @ -0.5 dBFS SFDR Spurious-Free Dynamic Range dBc AIN = 100 MHz @ -0.5 dBFS 68 AIN = 248 MHz @ -0.5 dBFS 66 59 66 57.9 AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS 68 dBc 66 dBc (min) 63 66 54 dBc (min) dBc (min) AIN = 748 MHz @ -0.5 dBFS dBc DES Mode (Demux and Non-Demux Modes, Q-input only) ENOB Effective Number of Bits AIN = 100 MHz @ -0.5 dBFS 8.6 8.9 bits AIN = 248 MHz @ -0.5 dBFS 8.5 8.7 bits 8.5 bits AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS 8.4 AIN = 748 MHz @ -0.5 dBFS SINAD Signal-to-Noise Plus Distortion Ratio 8.3 bits AIN = 100 MHz @ -0.5 dBFS 53.6 55.5 dB AIN = 248 MHz @ -0.5 dBFS 52.9 53.9 dB 52.7 dB AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS 52.3 AIN = 748 MHz @ -0.5 dBFS SNR Signal-to-Noise Ratio 55.9 dB AIN = 248 MHz @ -0.5 dBFS 53.3 54.6 dB 53.8 dB 52.7 AIN = 748 MHz @ -0.5 dBFS 52.1 dB -67 -66 dB AIN = 248 MHz @ -0.5 dBFS -64 -62 dB -59 dB AIN = 498 MHz @ -0.5 dBFS -63 AIN = 748 MHz @ -0.5 dBFS Second Harmonic Distortion dB AIN = 100 MHz @ -0.5 dBFS AIN = 373 MHz @ -0.5 dBFS 2nd Harm dB 53.8 AIN = 498 MHz @ -0.5 dBFS Total Harmonic Distortion dB 51.7 AIN = 100 MHz @ -0.5 dBFS AIN = 373 MHz @ -0.5 dBFS THD bits dB -62 dB AIN = 100 MHz @ -0.5 dBFS -77 -80 dBc AIN = 248 MHz @ -0.5 dBFS -66 -66 dBc -64 dBc AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS -66 AIN = 748 MHz @ -0.5 dBFS Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 dBc -70 Submit Documentation Feedback dBc 17 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Converter Electrical Characteristics - Dynamic Converter Characteristics (continued) The following specifications apply after calibration for VA = VDR = VTC = VE = +1.9V; I- and Q-channels, AC-coupled, unused channel terminated to AC ground, FSR Pin = High; CL = 10 pF; Differential, AC coupled Sine Wave Sampling Clock, fCLK = 1.0/1.5 GHz at 0.5 VP-P with 50% duty cycle (as specified); VBG = Floating; Non-Extended Control Mode; Rext = Rtrim = 3300 0.1%; Analog Signal Source Impedance = 100 Differential; 1:2 Demultiplex Non-DES Mode; Duty Cycle Stabilizer on. Boldface limits apply for TA = TMIN to TMAX. All other limits TA = 25C, unless otherwise noted. (1) (2) (3) (4) _ Symbol 3rd Harm Parameter Conditions Third Harmonic Distortion ADC10D1000 ADC10D1500 Typ Typ -69 -67 dBc -65 -70 dBc -62 dBc -63 AIN = 748 MHz @ -0.5 dBFS -62 dBc 59.3 67 dBc AIN = 248 MHz @ -0.5 dBFS 58.9 62 dBc 60 dBc AIN = 498 MHz @ -0.5 dBFS 57.4 AIN = 748 MHz @ -0.5 dBFS Submit Documentation Feedback dBc AIN = 100 MHz @ -0.5 dBFS AIN = 373 MHz @ -0.5 dBFS 18 Units (Limits) AIN = 248 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS Spurious-Free Dynamic Range Lim AIN = 100 MHz @ -0.5 dBFS AIN = 373 MHz @ -0.5 dBFS SFDR Lim dBc 59 dBc Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Converter Electrical Characteristics - Analog Input/Output and Reference Characteristics The following specifications apply after calibration for VA = VDR = VTC = VE = +1.9V; I- and Q-channels, AC-coupled, unused channel terminated to AC ground, FSR Pin = High; CL = 10 pF; Differential, AC coupled Sine Wave Sampling Clock, fCLK = 1.0/1.5 GHz at 0.5 VP-P with 50% duty cycle (as specified); VBG = Floating; Non-Extended Control Mode; Rext = Rtrim = 3300 0.1%; Analog Signal Source Impedance = 100 Differential; 1:2 Demultiplex Non-DES Mode; Duty Cycle Stabilizer on. Boldface limits apply for TA = TMIN to TMAX. All other limits TA = 25C, unless otherwise noted. (1) (2) (3) (4) _ Symbol Parameter Conditions ADC10D1000 ADC10D1500 Typ Typ Lim Lim Units (Limits) Analog Inputs VIN_FSR Analog Differential Input Full Scale Non-Extended Control Mode Range FSR Pin Low 540 mVP-P (min) 660 660 mVP-P (max) 720 720 mVP-P (min) 860 mVP-P (max) 540 600 FSR Pin High 600 790 790 860 Extended Control Mode CIN RIN FM(14:0) = 0000h 600 600 mVP-P FM(14:0) = 4000h (default) 790 790 mVP-P FM(14:0) = 7FFFh 980 980 mVP-P Analog Input Capacitance, Non-DES Mode (5) Differential 0.02 0.02 pF Each input pin to ground 1.6 1.6 pF Analog Input Capacitance, DES Mode (5) Differential 0.08 0.08 pF Each input pin to ground 2.2 2.2 pF Differential Input Resistance 100 96 104 100 93 (min) 107 (max) Common Mode Output VCMO Common Mode Output Voltage TC_VCMO Common Mode Output Voltage Temperature Coefficient VCMO_LVL VCMO input threshold to set DC-coupling Mode CL_VCMO Maximum VCMO Load Capacitance (1) ICMO = 100 A ICMO = 100 A 1.25 1.15 1.35 1.25 1.15 V (min) 1.35 V (max) 38 38 ppm/C 0.63 0.63 V (5) 80 80 pF The analog inputs, labeled "I/O", are protected as shown below. Input voltage magnitudes beyond the Absolute Maximum Ratings may damage this device. V A TO INTERNAL CIRCUITRY I/O GND (2) (3) (4) (5) To specify accuracy, it is required that VA, VTC, VE and VDR be well-bypassed. Each supply pin must be decoupled with separate bypass capacitors. Typical figures are at TA = 25C, and represent most likely parametric norms. Test limits are specified to AOQL (Average Outgoing Quality Level). The maximum clock frequency for Non-Demux Mode is tested up to 1.0 GHz for both the ADC10D1000 and the ADC10D1500 and specified by design and characterization up to 1.5 GHz for the ADC10D1500. This parameter is specified by design and is not tested in production. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 19 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Converter Electrical Characteristics - Analog Input/Output and Reference Characteristics (continued) The following specifications apply after calibration for VA = VDR = VTC = VE = +1.9V; I- and Q-channels, AC-coupled, unused channel terminated to AC ground, FSR Pin = High; CL = 10 pF; Differential, AC coupled Sine Wave Sampling Clock, fCLK = 1.0/1.5 GHz at 0.5 VP-P with 50% duty cycle (as specified); VBG = Floating; Non-Extended Control Mode; Rext = Rtrim = 3300 0.1%; Analog Signal Source Impedance = 100 Differential; 1:2 Demultiplex Non-DES Mode; Duty Cycle Stabilizer on. Boldface limits apply for TA = TMIN to TMAX. All other limits TA = 25C, unless otherwise noted. (1) (2) (3) (4) _ Symbol Parameter Conditions ADC10D1000 ADC10D1500 Typ Typ Lim Lim Units (Limits) Bandgap Reference VBG Bandgap Reference Output Voltage IBG = 100 A TC_VBG Bandgap Reference Voltage Temperature Coefficient IBG = 100 A CL_VBG Maximum Bandgap Reference load Capacitance 20 Submit Documentation Feedback 1.25 1.15 1.35 32 1.25 1.15 V (min) 1.35 V (max) 32 ppm/C (5) 80 80 pF Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Converter Electrical Characteristics - I-Channel to Q-Channel Characteristics The following specifications apply after calibration for VA = VDR = VTC = VE = +1.9V; I- and Q-channels, AC-coupled, unused channel terminated to AC ground, FSR Pin = High; CL = 10 pF; Differential, AC coupled Sine Wave Sampling Clock, fCLK = 1.0/1.5 GHz at 0.5 VP-P with 50% duty cycle (as specified); VBG = Floating; Non-Extended Control Mode; Rext = Rtrim = 3300 0.1%; Analog Signal Source Impedance = 100 Differential; 1:2 Demultiplex Non-DES Mode; Duty Cycle Stabilizer on. Boldface limits apply for TA = TMIN to TMAX. All other limits TA = 25C, unless otherwise noted. (1) (2) (3) (4) _ Symbol Parameter Conditions Offset Match X-TALK (1) ADC10D1000 ADC10D1500 Typ Typ Lim Lim Units (Limits) 2 2 LSB Positive Full-Scale Match Zero offset selected in Control Register 2 2 LSB Negative Full-Scale Match Zero offset selected in Control Register 2 2 LSB Phase Matching (I, Q) fIN = 1.0 GHz <1 <1 Degree Crosstalk from I-channel (Aggressor) to Q-channel (Victim) Aggressor = 867 MHz F.S. Victim = 100 MHz F.S. -70 -70 dB Crosstalk from Q-channel (Aggressor) to I-channel (Victim) Aggressor = 867 MHz F.S. Victim = 100 MHz F.S. -70 -70 dB The analog inputs, labeled "I/O", are protected as shown below. Input voltage magnitudes beyond the Absolute Maximum Ratings may damage this device. V A TO INTERNAL CIRCUITRY I/O GND (2) (3) (4) To specify accuracy, it is required that VA, VTC, VE and VDR be well-bypassed. Each supply pin must be decoupled with separate bypass capacitors. Typical figures are at TA = 25C, and represent most likely parametric norms. Test limits are specified to AOQL (Average Outgoing Quality Level). The maximum clock frequency for Non-Demux Mode is tested up to 1.0 GHz for both the ADC10D1000 and the ADC10D1500 and specified by design and characterization up to 1.5 GHz for the ADC10D1500. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 21 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Converter Electrical Characteristics - Sampling Clock Characteristics The following specifications apply after calibration for VA = VDR = VTC = VE = +1.9V; I- and Q-channels, AC-coupled, unused channel terminated to AC ground, FSR Pin = High; CL = 10 pF; Differential, AC coupled Sine Wave Sampling Clock, fCLK = 1.0/1.5 GHz at 0.5 VP-P with 50% duty cycle (as specified); VBG = Floating; Non-Extended Control Mode; Rext = Rtrim = 3300 0.1%; Analog Signal Source Impedance = 100 Differential; 1:2 Demultiplex Non-DES Mode; Duty Cycle Stabilizer on. Boldface limits apply for TA = TMIN to TMAX. All other limits TA = 25C, unless otherwise noted. (1) (2) (3) (4) _ Symbol VIN_CLK Parameter Conditions Differential Sampling Clock Input Level (5) CIN_CLK Square Wave Clock Differential Peak-to-Peak 0.6 Each input to ground (1) Typ 0.6 (6) Sampling Clock Differential Input Resistance ADC10D1500 Typ Sine Wave Clock Differential Peak-to-Peak Sampling Clock Input Capacitance Differential RIN_CLK ADC10D1000 Lim 0.4 2.0 0.4 2.0 0.6 0.6 Lim Units (Limits) 0.4 VP-P (min) 2.0 VP-P (max) 0.4 VP-P (min) 2.0 VP-P (max) 0.1 0.1 pF 1 1 pF 100 100 The analog inputs, labeled "I/O", are protected as shown below. Input voltage magnitudes beyond the Absolute Maximum Ratings may damage this device. V A TO INTERNAL CIRCUITRY I/O GND (2) (3) (4) (5) (6) 22 To specify accuracy, it is required that VA, VTC, VE and VDR be well-bypassed. Each supply pin must be decoupled with separate bypass capacitors. Typical figures are at TA = 25C, and represent most likely parametric norms. Test limits are specified to AOQL (Average Outgoing Quality Level). The maximum clock frequency for Non-Demux Mode is tested up to 1.0 GHz for both the ADC10D1000 and the ADC10D1500 and specified by design and characterization up to 1.5 GHz for the ADC10D1500. This parameter is specified by design and/or characterization and is not tested in production. This parameter is specified by design and is not tested in production. Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Converter Electrical Characteristics - Digital Control and Output Pin Characteristics The following specifications apply after calibration for VA = VDR = VTC = VE = +1.9V; I- and Q-channels, AC-coupled, unused channel terminated to AC ground, FSR Pin = High; CL = 10 pF; Differential, AC coupled Sine Wave Sampling Clock, fCLK = 1.0/1.5 GHz at 0.5 VP-P with 50% duty cycle (as specified); VBG = Floating; Non-Extended Control Mode; Rext = Rtrim = 3300 0.1%; Analog Signal Source Impedance = 100 Differential; 1:2 Demultiplex Non-DES Mode; Duty Cycle Stabilizer on. Boldface limits apply for TA = TMIN to TMAX. All other limits TA = 25C, unless otherwise noted. (1) (2) (3) (4) _ Symbol Parameter Conditions ADC10D1000 ADC10D1500 Typ Typ Lim Lim Units (Limits) Digital Control Pins (DES, CalDly, CAL, PDI, PDQ, TPM, NDM, FSR, DDRPh, ECE, SCLK, SDI, SCS) VIH Logic High Input Voltage 0.7xVA 0.7xVA V (min) VIL Logic Low Input Voltage 0.3xVA 0.3xVA V (max) IIH Input Leakage Current; VIN = VA IIL Input Leakage Current; VIN = GND CIN_DIG 0.02 0.02 A -0.02 -0.02 A SCS, SCLK, SDI -17 -17 A PDI, PDQ, ECE -38 -38 A Measured from each control pin to GND 1.5 1.5 pF FSR, CalDly, CAL, NDM, TPM, DDRPh, DES Digital Control Pin Input Capacitance (5) Digital Output Pins (Data, DCLKI, DCLKQ, ORI, ORQ) VOD LVDS Differential Output Voltage VBG = Floating, OVS = High 375 mVP-P (min) 750 750 mVP-P (max) 260 260 mVP-P (min) 560 mVP-P (max) 375 560 VBG = Floating, OVS = Low 560 400 400 560 VO DIFF VOS (1) 600 600 mVP-P VBG = VA, OVS = Low 440 440 mVP-P 1 1 mV VBG = Floating 0.8 0.8 V VBG = VA 1.2 1.2 V 1 1 mV Change in LVDS Output Swing Between Logic Levels Output Offset Voltage VOS VBG = VA, OVS = High Output Offset Voltage Change Between Logic Levels The analog inputs, labeled "I/O", are protected as shown below. Input voltage magnitudes beyond the Absolute Maximum Ratings may damage this device. V A TO INTERNAL CIRCUITRY I/O GND (2) (3) (4) (5) To specify accuracy, it is required that VA, VTC, VE and VDR be well-bypassed. Each supply pin must be decoupled with separate bypass capacitors. Typical figures are at TA = 25C, and represent most likely parametric norms. Test limits are specified to AOQL (Average Outgoing Quality Level). The maximum clock frequency for Non-Demux Mode is tested up to 1.0 GHz for both the ADC10D1000 and the ADC10D1500 and specified by design and characterization up to 1.5 GHz for the ADC10D1500. This parameter is specified by design and is not tested in production. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 23 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Converter Electrical Characteristics - Digital Control and Output Pin Characteristics (continued) The following specifications apply after calibration for VA = VDR = VTC = VE = +1.9V; I- and Q-channels, AC-coupled, unused channel terminated to AC ground, FSR Pin = High; CL = 10 pF; Differential, AC coupled Sine Wave Sampling Clock, fCLK = 1.0/1.5 GHz at 0.5 VP-P with 50% duty cycle (as specified); VBG = Floating; Non-Extended Control Mode; Rext = Rtrim = 3300 0.1%; Analog Signal Source Impedance = 100 Differential; 1:2 Demultiplex Non-DES Mode; Duty Cycle Stabilizer on. Boldface limits apply for TA = TMIN to TMAX. All other limits TA = 25C, unless otherwise noted. (1) (2) (3) (4) _ Symbol Parameter Conditions IOS Output Short Circuit Current VBG = Floating; D+ and D- connected to 0.8V ZO Differential Output Impedance VOH Logic High Output Level CalRun, SDO IOH = -400 A VOL Logic Low Output Level CalRun, SDO IOL = 400 A (6) (6) ADC10D1000 ADC10D1500 Typ Typ Lim Lim Units (Limits) 4 4 mA 100 100 1.65 1.5 1.65 1.5 V 0.15 0.3 0.15 0.3 V Differential DCLK Reset Pins (DCLK_RST) VCMI_DRST DCLK_RST Common Mode Input Voltage 1.250. 15 1.250. 15 V VID_DRST Differential DCLK_RST Input Voltage VIN_CLK VIN_CLK VP-P RIN_DRST Differential DCLK_RST Input Resistance 100 100 (6) 24 (5) This parameter is specified by design and/or characterization and is not tested in production. Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Converter Electrical Characteristics - Power Supply Characteristics The following specifications apply after calibration for VA = VDR = VTC = VE = +1.9V; I- and Q-channels, AC-coupled, unused channel terminated to AC ground, FSR Pin = High; CL = 10 pF; Differential, AC coupled Sine Wave Sampling Clock, fCLK = 1.0/1.5 GHz at 0.5 VP-P with 50% duty cycle (as specified); VBG = Floating; Non-Extended Control Mode; Rext = Rtrim = 3300 0.1%; Analog Signal Source Impedance = 100 Differential; 1:2 Demultiplex Non-DES Mode; Duty Cycle Stabilizer on. Boldface limits apply for TA = TMIN to TMAX. All other limits TA = 25C, unless otherwise noted. (1) (2) (3) (4) _ Symbol IA Parameter ADC10D1000 ADC10D1500 Typ Lim Typ PDI = PDQ = Low 895 985 1170 mA (max) PDI = Low; PDQ = High 510 645 mA PDI = High; PDQ = Low 510 645 mA 2 2 mA 1095 mA (max) Conditions Analog Supply Current Non-Demux Mode (4) PDI = PDQ = Low 895 PDI = Low; PDQ = High 510 600 mA PDI = High; PDQ = Low 510 600 mA 2 2 mA PDI = PDQ = High Track-and-Hold and Clock Supply Current 985 1:2 Demux Mode PDI = PDQ = Low 360 425 mA (max) PDI = Low; PDQ = High 220 260 mA PDI = High; PDQ = Low 220 260 mA 1 1.5 mA 370 mA (max) PDI = PDQ = High Non-Demux Mode 400 (4) PDI = PDQ = Low 360 PDI = Low; PDQ = High 220 225 mA PDI = High; PDQ = Low 220 225 mA 1 1.5 mA PDI = PDQ = High (1) Units (Limits) 1:2 Demux Mode PDI = PDQ = High ITC Lim 400 The analog inputs, labeled "I/O", are protected as shown below. Input voltage magnitudes beyond the Absolute Maximum Ratings may damage this device. V A TO INTERNAL CIRCUITRY I/O GND (2) (3) (4) To specify accuracy, it is required that VA, VTC, VE and VDR be well-bypassed. Each supply pin must be decoupled with separate bypass capacitors. Typical figures are at TA = 25C, and represent most likely parametric norms. Test limits are specified to AOQL (Average Outgoing Quality Level). The maximum clock frequency for Non-Demux Mode is tested up to 1.0 GHz for both the ADC10D1000 and the ADC10D1500 and specified by design and characterization up to 1.5 GHz for the ADC10D1500. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 25 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Converter Electrical Characteristics - Power Supply Characteristics (continued) The following specifications apply after calibration for VA = VDR = VTC = VE = +1.9V; I- and Q-channels, AC-coupled, unused channel terminated to AC ground, FSR Pin = High; CL = 10 pF; Differential, AC coupled Sine Wave Sampling Clock, fCLK = 1.0/1.5 GHz at 0.5 VP-P with 50% duty cycle (as specified); VBG = Floating; Non-Extended Control Mode; Rext = Rtrim = 3300 0.1%; Analog Signal Source Impedance = 100 Differential; 1:2 Demultiplex Non-DES Mode; Duty Cycle Stabilizer on. Boldface limits apply for TA = TMIN to TMAX. All other limits TA = 25C, unless otherwise noted. (1) (2) (3) (4) _ Symbol IDR Parameter ADC10D1000 ADC10D1500 Typ Lim Typ PDI = PDQ = Low 210 260 220 mA (max) PDI = Low; PDQ = High 115 120 mA PDI = High; PDQ = Low 115 120 mA PDI = PDQ = High 10 15 A 125 mA (max) Conditions Output Driver Supply Current Digital Encoder Supply Current (4) PDI = PDQ = Low 135 PDI = Low; PDQ = High 80 75 mA PDI = High; PDQ = Low 80 75 mA PDI = PDQ = High 10 15 A PDI = PDQ = Low 60 100 mA (max) PDI = Low; PDQ = High 35 50 mA PDI = High; PDQ = Low 35 50 mA PDI = PDQ = High 10 70 A 100 65 mA (max) (4) PDI = PDQ = Low 68 PDI = Low; PDQ = High 40 40 mA PDI = High; PDQ = Low 40 40 mA PDI = PDQ = High 10 70 A 1525 1745 1915 2092 mA (max) PDI = PDQ = Low 2.90 3.31 3.64 3.98 W (max) PDI = Low; PDQ = High 1.66 2.00 PDI = High; PDQ = Low 1.66 2.00 W 6 7 mW ITOTAL Total Supply Current 1:2 Demux Mode PDI = PDQ = Low PC Power Consumption 1:2 Demux Mode PDI = PDQ = High Non-Demux Mode 100 W (4) PDI = PDQ = Low 2.77 3.14 W (max) PDI = Low; PDQ = High 1.61 1.68 W PDI = High; PDQ = Low 1.61 1.68 W 6 7 mW PDI = PDQ = High Submit Documentation Feedback 170 1:2 Demux Mode Non-Demux Mode 26 Units (Limits) 1:2 Demux Mode Non-Demux Mode IE Lim 3.14 Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Converter Electrical Characteristics - AC Electrical Characteristics The following specifications apply after calibration for VA = VDR = VTC = VE = +1.9V; I- and Q-channels, AC-coupled, unused channel terminated to AC ground, FSR Pin = High; CL = 10 pF; Differential, AC coupled Sine Wave Sampling Clock, fCLK = 1.0/1.5 GHz at 0.5 VP-P with 50% duty cycle (as specified); VBG = Floating; Non-Extended Control Mode; Rext = Rtrim = 3300 0.1%; Analog Signal Source Impedance = 100 Differential; 1:2 Demultiplex Non-DES Mode; Duty Cycle Stabilizer on. Boldface limits apply for TA = TMIN to TMAX. All other limits TA = 25C, unless otherwise noted. (1) (2) (3) (4) _ Symbol Parameter Conditions ADC10D1000 ADC10D1500 Typ Typ Lim Lim Units (Limits) 1.5 GHz (min) Sampling Clock (CLK) fCLK (max) Maximum Sampling Clock Frequency fCLK (min) Minimum Sampling Clock Frequency Non-DES Mode 200 DES Mode 250 Sampling Clock Duty Cycle fCLK(min) fCLK fCLK(max) 1.0 (5) tCL Sampling Clock Low Time (6) tCH Sampling Clock High Time (6) 50 200 MHz 250 20 80 50 MHz 20 % (min) 80 % (max) 500 200 333 133 ps (min) 500 200 333 133 ps (min) Data Clock (DCLKI, DCLKQ) (6) DCLK Duty Cycle 50 45 55 50 45 % (min) 55 % (max) tSR Setup Time DCLK_RST (5) 45 45 ps tHR Hold Time DCLK_RST (5) 45 45 ps Pulse Width DCLK_RST (6) tPWR tSYNC_DLY DCLK Synchronization Delay 90 Mode 0 Mode (6) (6) 5 5 4 4 5 5 Sampling Clock Cycles (min) Sampling Clock Cycles tLHT Differential Low-to-High Transition Time 10%-to-90%, CL = 2.5 pF 220 220 ps tHLT Differential High-to-Low Transition Time 10%-to-90%, CL = 2.5 pF 220 220 ps tSU Data-to-DCLK Setup Time 90 Mode (6) 850 545 ps tH DCLK-to-Data Hold Time 90 Mode (6) 850 570 ps (1) The analog inputs, labeled "I/O", are protected as shown below. Input voltage magnitudes beyond the Absolute Maximum Ratings may damage this device. V A TO INTERNAL CIRCUITRY I/O GND (2) (3) (4) (5) (6) To specify accuracy, it is required that VA, VTC, VE and VDR be well-bypassed. Each supply pin must be decoupled with separate bypass capacitors. Typical figures are at TA = 25C, and represent most likely parametric norms. Test limits are specified to AOQL (Average Outgoing Quality Level). The maximum clock frequency for Non-Demux Mode is tested up to 1.0 GHz for both the ADC10D1000 and the ADC10D1500 and specified by design and characterization up to 1.5 GHz for the ADC10D1500. This parameter is specified by design and/or characterization and is not tested in production. This parameter is specified by design and is not tested in production. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 27 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Converter Electrical Characteristics - AC Electrical Characteristics (continued) The following specifications apply after calibration for VA = VDR = VTC = VE = +1.9V; I- and Q-channels, AC-coupled, unused channel terminated to AC ground, FSR Pin = High; CL = 10 pF; Differential, AC coupled Sine Wave Sampling Clock, fCLK = 1.0/1.5 GHz at 0.5 VP-P with 50% duty cycle (as specified); VBG = Floating; Non-Extended Control Mode; Rext = Rtrim = 3300 0.1%; Analog Signal Source Impedance = 100 Differential; 1:2 Demultiplex Non-DES Mode; Duty Cycle Stabilizer on. Boldface limits apply for TA = TMIN to TMAX. All other limits TA = 25C, unless otherwise noted. (1) (2) (3) (4) _ Symbol tOSK Parameter Conditions DCLK-to-Data Output Skew ADC10D1000 ADC10D1500 Typ Typ Lim Lim Units (Limits) 50% of DCLK transition to 50% of Data transition (6) 50 50 ps (max) Sampling CLK+ Rise to Acquisition of Data 1.1 1.1 ns 0.2 0.2 ps (rms) 2.4 2.4 ns Data Input-to-Output tAD Aperture Delay tAJ Aperture Jitter tOD Sampling Clock-to Data Output Delay (in addition to Latency) 50% of Sampling Clock transition to 50% of Data transition tLAT Latency in 1:2 Demux Non-DES Mode (6) DI, DQ Outputs 34 34 DId, DQd Outputs 35 35 Latency in 1:4 Demux DES Mode DI Outputs 34 34 DQ Outputs 34.5 34.5 DId Outputs 35 35 DQd Outputs 35.5 35.5 DI Outputs 34 34 DQ Outputs 34 34 34 34 34.5 34.5 (6) Latency in Non-Demux Non-DES Mode (6) Latency in Non-Demux DES Mode DI Outputs (6) DQ Outputs tORR tWU Over Range Recovery Time Wake-Up Time (PDI/PDQ low to Rated Accuracy Conversion) Differential VIN step from 1.2V to 0V to accurate conversion Non-DES Mode DES Mode (6) (6) Sampling Clock Cycles Sampling Clock Cycle 1 1 500 500 ns 1 1 s Serial Port Interface fSCLK (6) Serial Clock Frequency 15 Serial Clock Low Time Serial Clock High Time Serial Data-to-Serial Clock Rising Setup Time (6) tSH Serial Data-to-Serial Clock Rising Hold Time (7) tSCS tSSU 15 MHz 30 30 ns (min) 30 30 ns (min) 2.5 2.5 ns (min) 1 1 ns (min) SCS-to-Serial Clock Rising Setup Time 2.5 2.5 ns tHCS SCS-to-Serial Clock Falling Hold Time 1.5 1.5 ns tBSU Bus turn-around time 10 10 ns (7) 28 This parameter is specified by design and is not tested in production. Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Converter Electrical Characteristics - AC Electrical Characteristics (continued) The following specifications apply after calibration for VA = VDR = VTC = VE = +1.9V; I- and Q-channels, AC-coupled, unused channel terminated to AC ground, FSR Pin = High; CL = 10 pF; Differential, AC coupled Sine Wave Sampling Clock, fCLK = 1.0/1.5 GHz at 0.5 VP-P with 50% duty cycle (as specified); VBG = Floating; Non-Extended Control Mode; Rext = Rtrim = 3300 0.1%; Analog Signal Source Impedance = 100 Differential; 1:2 Demultiplex Non-DES Mode; Duty Cycle Stabilizer on. Boldface limits apply for TA = TMIN to TMAX. All other limits TA = 25C, unless otherwise noted. (1) (2) (3) (4) _ Symbol Parameter Conditions ADC10D1000 ADC10D1500 Typ Typ Lim Lim Units (Limits) Calibration tCAL Calibration Cycle Time 2.4*107 2.4*107 7 2.3*10 2.3*107 CMS(1:0) = 00b 0.8*107 0.8*107 CMS(1:0) = 01b 7 1.5*10 1.5*107 CMS(1:0) = 10b (ECM default) 2.4*107 2.4*107 Non-ECM ECM CSS = 0b Sampling Clock Cycles ECM; CSS = 1b tCAL_L tCAL_H tCalDly (8) Sampling Clock Cycles (8) CAL Pin Low Time 1280 1280 Clock Cycles (min) 1280 1280 Clock Cycles (min) CalDly = Low 224 224 CalDly = High 230 230 (8) CAL Pin High Time Calibration delay determined by CalDly Pin (8) Clock Cycles (max) This parameter is specified by design and is not tested in production. Specification Definitions APERTURE (SAMPLING) DELAY is the amount of delay, measured from the sampling edge of the CLK input, after which the signal present at the input pin is sampled inside the device. APERTURE JITTER (tAJ) is the variation in aperture delay from sample-to-sample. Aperture jitter can be effectively considered as noise at the input. CODE ERROR RATE (CER) is the probability of error and is defined as the probable number of word errors on the ADC output per unit of time divided by the number of words seen in that amount of time. A CER of 10-18 corresponds to a statistical error in one word about every 31.7 years. CLOCK DUTY CYCLE is the ratio of the time that the clock waveform is at a logic high to the total time of one clock period. DIFFERENTIAL NON-LINEARITY (DNL) is the measure of the maximum deviation from the ideal step size of 1 LSB. It is measured at the relevant sample rate, fCLK, with fIN = 1MHz sine wave. EFFECTIVE NUMBER OF BITS (ENOB, or EFFECTIVE BITS) is another method of specifying Signal-to-Noise and Distortion Ratio, or SINAD. ENOB is defined as (SINAD - 1.76) / 6.02 and states that the converter is equivalent to a perfect ADC of this many (ENOB) number of bits. FULL POWER BANDWIDTH (FPBW) is a measure of the frequency at which the reconstructed output fundamental drops to 3 dB below its low frequency value for a full-scale input. GAIN ERROR is the deviation from the ideal slope of the transfer function. It can be calculated from Offset and Full-Scale Errors. The Positive Gain Error is the Offset Error minus the Positive Full-Scale Error. The Negative Gain Error is the Negative Full-Scale Error minus the Offset Error. The Gain Error is the Negative Full-Scale Error minus the Positive Full-Scale Error; it is also equal to the Positive Gain Error plus the Negative Gain Error. INTEGRAL NON-LINEARITY (INL) is a measure of worst case deviation of the ADC transfer function from an ideal straight line drawn through the ADC transfer function. The deviation of any given code from this straight line is measured from the center of that code value step. The best fit method is used. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 29 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com LSB (LEAST SIGNIFICANT BIT) is the bit that has the smallest value or weight of all bits. This value is VFS / 2N (1) where VFS is the differential full-scale amplitude VIN_FSR as set by the FSR input and "N" is the ADC resolution in bits, which is 10 for the ADC10D1000/1500. LOW VOLTAGE DIFFERENTIAL SIGNALING (LVDS) DIFFERENTIAL OUTPUT VOLTAGE (VID and VOD) is two times the absolute value of the difference between the VD+ and VD- signals; each signal measured with respect to Ground. VOD peak is VOD,P= (VD+ - VD-) and VOD peak-to-peak is VOD,P-P= 2*(VD+ - VD-); for this product, the VOD is measured peak-to-peak. VD+ VDVOS 1/2xVOD VD+ VD - GND 1/2xVOD = | VD+ - VD- | Figure 3. LVDS Output Signal Levels LVDS OUTPUT OFFSET VOLTAGE (VOS) is the midpoint between the D+ and D- pins output voltage with respect to ground; i.e., [(VD+) +( VD-)]/2. See Figure 3. MISSING CODES are those output codes that are skipped and will never appear at the ADC outputs. These codes cannot be reached with any input value. MSB (MOST SIGNIFICANT BIT) is the bit that has the largest value or weight. Its value is one half of full scale. NEGATIVE FULL-SCALE ERROR (NFSE) is a measure of how far the first code transition is from the ideal 1/2 LSB above a differential -VIN/2 with the FSR pin low. For the ADC10D1000/1500 the reference voltage is assumed to be ideal, so this error is a combination of full-scale error and reference voltage error. NOISE POWER RATIO (NPR) is the ratio of the sum of the power inside the notched bins to the sum of the power in an equal number of bins outside the notch, expressed in dB. NPR is similar to, but more complete than intermodulation distortion measurements. OFFSET ERROR (VOFF) is a measure of how far the mid-scale point is from the ideal zero voltage differential input. Offset Error = Actual Input causing average of 8k samples to result in an average code of 511.5. OUTPUT DELAY (tOD) is the time delay (in addition to Latency) after the rising edge of CLK+ before the data update is present at the output pins. OVER-RANGE RECOVERY TIME is the time required after the differential input voltages goes from 1.2V to 0V for the converter to recover and make a conversion with its rated accuracy. PIPELINE DELAY (LATENCY) is the number of input clock cycles between initiation of conversion and when that data is presented to the output driver stage. The data lags the conversion by the Latency plus the tOD. POSITIVE FULL-SCALE ERROR (PFSE) is a measure of how far the last code transition is from the ideal 1-1/2 LSB below a differential +VIN/2. For the ADC10D1000/1500 the reference voltage is assumed to be ideal, so this error is a combination of full-scale error and reference voltage error. SIGNAL TO NOISE RATIO (SNR) is the ratio, expressed in dB, of the rms value of the fundamental for a singletone to the rms value of the sum of all other spectral components below one-half the sampling frequency, not including harmonics or DC. 30 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 SIGNAL TO NOISE PLUS DISTORTION (S/(N+D) or SINAD) is the ratio, expressed in dB, of the rms value of the fundamental for a single-tone to the rms value of all of the other spectral components below half the input clock frequency, including harmonics but excluding DC. SPURIOUS-FREE DYNAMIC RANGE (SFDR) is the difference, expressed in dB, between the rms values of the input signal at the output and the peak spurious signal, where a spurious signal is any signal present in the output spectrum that is not present at the input, excluding DC. JA is the thermal resistance between the junction to ambient. JC1 represents the thermal resistance between the die and the exposed metal area on the top of the HSBGA package. JC2 represents the thermal resistance between the die and the center group of balls on the bottom of the HSBGA package. TOTAL HARMONIC DISTORTION (THD) is the ratio expressed in dB, of the rms total of the first nine harmonic levels at the output to the level of the fundamental at the output. THD is calculated as THD = 20 x log A 2 +... +A 2 f2 f10 A f12 (2) where Af1 is the RMS power of the fundamental (output) frequency and Af2 through Af10 are the RMS power of the first 9 harmonic frequencies in the output spectrum. - Second Harmonic Distortion (2nd Harm) is the difference, expressed in dB, between the RMS power in the input frequency seen at the output and the power in its 2nd harmonic level at the output. - Third Harmonic Distortion (3rd Harm) is the difference expressed in dB between the RMS power in the input frequency seen at the output and the power in its 3rd harmonic level at the output. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 31 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Transfer Characteristic IDEAL POSITIVE FULL-SCALE TRANSITION Output Code ACTUAL POSITIVE FULL-SCALE TRANSITION 11 1111 1111 (1023) 11 1111 1110 (1022) 11 1111 1101 (1021) POSITIVE FULL-SCALE ERROR MID-SCALE TRANSITION 10 0000 0000 (512) 01 1111 1111 (511) OFFSET ERROR IDEAL NEGATIVE FULL-SCALE TRANSITION NEGATIVE FULL-SCALE ERROR ACTUAL NEGATIVE FULL-SCALE TRANSITION 00 0000 0010 (2) 00 0000 0001 (1) 00 0000 0000 (0) -VIN/2 (VIN+) < (VIN-) (VIN+) > (VIN-) 0.0V +VIN/2 Differential Analog Input Voltage (+VIN/2) - (-VIN/2) Figure 4. Input / Output Transfer Characteristic 32 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 TEST CIRCUIT DIAGRAMS Timing Diagrams Sample N DI Sample N-1 DId VINI+/- Sample N+1 tAD CLK+ tOD DId, DI Sample N-39 and Sample N-38 Sample N-37 and Sample N-36 Sample N-35 and Sample N-34 tOSK DCLKI+/(0 Phase) tSU tH DCLKI+/(90 Phase) * Note: The timing for Figure 5 - Figure 8 is shown for the one input only (I or Q). However, both I- and Q-inputs may be used. For this case, the I-channel functions precisely the same as the Q-channel, with VinI, DCLKI, DId and DI instead of VinQ, DCLKQ, DQd and DQ. Both I- and Q-channel use the same CLK. Figure 5. Clocking in 1:2 Demux Non-DES Mode* Sample N Sample N-1 DQ DQ VINQ+/- Sample N+1 tAD CLK+ tOD DQ Sample N-37 Sample N-36 Sample N-35 Sample N-34 Sample N-33 tOSK DCLKQ+/(0 Phase) Figure 6. Clocking in Non-Demux Non-DES Mode (See note at Figure 5) Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 33 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 DId DQd VINQ+/- c Sample N-1.5 Sample N-1 www.ti.com DQ DI c c Sample N Sample N-0.5 c Sample N+1 tAD c c CLK+/tOD DQd, DId, DQ, DI Sample N-37.5, N-37, N-36.5, N-36 Sample N-39.5, N-39, N-38.5, N-38 Sample N-35.5, N-35, N-34.5, N-34 tOSK DCLKQ+/(0 Phase) tSU tH DCLKQ+/(90 Phase) Figure 7. Clocking in 1:4 Demux DES Mode (See note at Figure 5) Sample N-1 DI Sample N - 0.5 DQ Sample N DI VINQ+/- Sample N + 0.5 DQ Sample N+1 tAD CLK+ tOD DQ, DI Sample N-37.5, N-37 Sample N-36.5, N-36 Sample N-35.5, N-35 Sample N-34.5, N-34 Sample N-33.5, N-33 tOSK DCLKQ+/(0 Phase) Figure 8. Clocking in Non-Demux Mode DES Mode (See note at Figure 5) 34 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Synchronizing Edge tSYNC_DLY CLK tHR tSR DCLK_RSTtOD DCLK_RST+ tPWR DCLKI+ DCLKQ+ Figure 9. Data Clock Reset Timing (Demux Mode) tCAL tCAL CalRun tCAL_H tCalDly Calibration Delay determined by CalDly (Pin V4) CAL tCAL_L POWER SUPPLY Figure 10. Power-on and On-Command Calibration Timing Single Register Access SCS tSCS tHCS tHCS 1 8 24 9 SCLK SDI Command Field Data Field LSB MSB tSH tSSU tBSU SDO read mode) Data Field High Z MSB High Z LSB Figure 11. Serial Interface Timing Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 35 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Typical Performance Plots VA = VDR = VTC = VE = 1.9V, fCLK = 1.0/1.5 GHz, fIN = 498/748 MHz, TA= 25C, I-channel, 1:2 Demux Non-DES Mode (1:1 Demux Non-DES Mode has similar performance), unless otherwise stated. For NPR plots, notch width = 5%, fc = 325 MHz. 36 INL vs. CODE (ADC10D1000) INL vs. CODE (ADC10D1500) Figure 12. Figure 13. INL vs. TEMPERATURE (ADC10D1000) INL vs. TEMPERATURE (ADC10D1500) Figure 14. Figure 15. DNL vs. CODE (ADC10D1000) DNL vs. CODE (ADC10D1500) Figure 16. Figure 17. Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Typical Performance Plots (continued) VA = VDR = VTC = VE = 1.9V, fCLK = 1.0/1.5 GHz, fIN = 498/748 MHz, TA= 25C, I-channel, 1:2 Demux Non-DES Mode (1:1 Demux Non-DES Mode has similar performance), unless otherwise stated. For NPR plots, notch width = 5%, fc = 325 MHz. DNL vs. TEMPERATURE (ADC10D1000) DNL vs. TEMPERATURE (ADC10D1500) Figure 18. Figure 19. ENOB vs. TEMPERATURE (ADC10D1000) ENOB vs. TEMPERATURE (ADC10D1500) Figure 20. Figure 21. ENOB vs. SUPPLY VOLTAGE (ADC10D1000) ENOB vs. SUPPLY VOLTAGE (ADC10D1500) Figure 22. Figure 23. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 37 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Typical Performance Plots (continued) VA = VDR = VTC = VE = 1.9V, fCLK = 1.0/1.5 GHz, fIN = 498/748 MHz, TA= 25C, I-channel, 1:2 Demux Non-DES Mode (1:1 Demux Non-DES Mode has similar performance), unless otherwise stated. For NPR plots, notch width = 5%, fc = 325 MHz. 38 ENOB vs. CLOCK FREQUENCY (ADC10D1000) ENOB vs. CLOCK FREQUENCY (ADC10D1500) Figure 24. Figure 25. ENOB vs. INPUT FREQUENCY (ADC10D1000) ENOB vs. INPUT FREQUENCY (ADC10D1500) Figure 26. Figure 27. ENOB vs. VCMI (ADC10D1000) ENOB vs. VCMI (ADC10D1500) Figure 28. Figure 29. Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Typical Performance Plots (continued) VA = VDR = VTC = VE = 1.9V, fCLK = 1.0/1.5 GHz, fIN = 498/748 MHz, TA= 25C, I-channel, 1:2 Demux Non-DES Mode (1:1 Demux Non-DES Mode has similar performance), unless otherwise stated. For NPR plots, notch width = 5%, fc = 325 MHz. SNR vs. TEMPERATURE (ADC10D1000) SNR vs. TEMPERATURE (ADC10D1500) Figure 30. Figure 31. SNR vs. SUPPLY VOLTAGE (ADC10D1000) SNR vs. SUPPLY VOLTAGE (ADC10D1500) Figure 32. Figure 33. SNR vs. CLOCK FREQUENCY (ADC10D1000) SNR vs. CLOCK FREQUENCY (ADC10D1500) Figure 34. Figure 35. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 39 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Typical Performance Plots (continued) VA = VDR = VTC = VE = 1.9V, fCLK = 1.0/1.5 GHz, fIN = 498/748 MHz, TA= 25C, I-channel, 1:2 Demux Non-DES Mode (1:1 Demux Non-DES Mode has similar performance), unless otherwise stated. For NPR plots, notch width = 5%, fc = 325 MHz. 40 SNR vs. INPUT FREQUENCY (ADC10D1000) SNR vs. INPUT FREQUENCY (ADC10D1500) Figure 36. Figure 37. THD vs. TEMPERATURE (ADC10D1000) THD vs. TEMPERATURE (ADC10D1500) Figure 38. Figure 39. THD vs. SUPPLY VOLTAGE (ADC10D1000) THD vs. SUPPLY VOLTAGE (ADC10D1500) Figure 40. Figure 41. Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Typical Performance Plots (continued) VA = VDR = VTC = VE = 1.9V, fCLK = 1.0/1.5 GHz, fIN = 498/748 MHz, TA= 25C, I-channel, 1:2 Demux Non-DES Mode (1:1 Demux Non-DES Mode has similar performance), unless otherwise stated. For NPR plots, notch width = 5%, fc = 325 MHz. THD vs. CLOCK FREQUENCY (ADC10D1000) THD vs. CLOCK FREQUENCY (ADC10D1500) Figure 42. Figure 43. THD vs. INPUT FREQUENCY (ADC10D1000) THD vs. INPUT FREQUENCY (ADC10D1500) Figure 44. Figure 45. SFDR vs. TEMPERATURE (ADC10D1000) SFDR vs. TEMPERATURE (ADC10D1500) Figure 46. Figure 47. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 41 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Typical Performance Plots (continued) VA = VDR = VTC = VE = 1.9V, fCLK = 1.0/1.5 GHz, fIN = 498/748 MHz, TA= 25C, I-channel, 1:2 Demux Non-DES Mode (1:1 Demux Non-DES Mode has similar performance), unless otherwise stated. For NPR plots, notch width = 5%, fc = 325 MHz. 42 SFDR vs. SUPPLY VOLTAGE (ADC10D1000) SFDR vs. SUPPLY VOLTAGE (ADC10D1500) Figure 48. Figure 49. SFDR vs. CLOCK FREQUENCY (ADC10D1000) SFDR vs. CLOCK FREQUENCY (ADC10D1500) Figure 50. Figure 51. SFDR vs. INPUT FREQUENCY (ADC10D1000) SFDR vs. INPUT FREQUENCY (ADC10D1500) Figure 52. Figure 53. Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Typical Performance Plots (continued) VA = VDR = VTC = VE = 1.9V, fCLK = 1.0/1.5 GHz, fIN = 498/748 MHz, TA= 25C, I-channel, 1:2 Demux Non-DES Mode (1:1 Demux Non-DES Mode has similar performance), unless otherwise stated. For NPR plots, notch width = 5%, fc = 325 MHz. SPECTRAL RESPONSE AT FIN = 248 MHz (ADC10D1000) SPECTRAL RESPONSE AT FIN = 373 MHz (ADC10D1500) Figure 54. Figure 55. SPECTRAL RESPONSE AT FIN = 498 MHz (ADC10D1000) SPECTRAL RESPONSE AT FIN = 748 MHz (ADC10D1500) Figure 56. Figure 57. CROSSTALK vs. SOURCE FREQUENCY (ADC10D1000) CROSSTALK vs. SOURCE FREQUENCY (ADC10D1500) Figure 58. Figure 59. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 43 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Typical Performance Plots (continued) VA = VDR = VTC = VE = 1.9V, fCLK = 1.0/1.5 GHz, fIN = 498/748 MHz, TA= 25C, I-channel, 1:2 Demux Non-DES Mode (1:1 Demux Non-DES Mode has similar performance), unless otherwise stated. For NPR plots, notch width = 5%, fc = 325 MHz. FULL POWER BANDWIDTH (ADC10D1500) 0 0 -3 -3 SIGNAL GAIN (dB) SIGNAL GAIN (dB) FULL POWER BANDWIDTH (ADC10D1000) -6 -9 -12 0 -9 -12 NON-DES MODE DES MODE DESIQ MODE -15 -6 NON-DES MODE DES MODE DESIQ MODE -15 1000 2000 INPUT FREQUENCY (MHz) 3000 0 1000 2000 INPUT FREQUENCY (MHz) 3000 Figure 60. Figure 61. POWER CONSUMPTION vs. CLOCK FREQUENCY (ADC10D1000) POWER CONSUMPTION vs. CLOCK FREQUENCY (ADC10D1500) Figure 62. Figure 63. NPR vs. RMS NOISE LOADING LEVEL (ADC10D1000) Figure 64. 44 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Typical Performance Plots (continued) VA = VDR = VTC = VE = 1.9V, fCLK = 1.0/1.5 GHz, fIN = 498/748 MHz, TA= 25C, I-channel, 1:2 Demux Non-DES Mode (1:1 Demux Non-DES Mode has similar performance), unless otherwise stated. For NPR plots, notch width = 5%, fc = 325 MHz. NPR vs. FC,NOTCH (ADC10D1000) NPR SPECTRAL RESPONSE (ADC10D1000) Figure 65. Figure 66. Functional Description The ADC10D1000/1500 is a versatile A/D converter with an innovative architecture which permits very high speed operation. The controls available ease the application of the device to circuit solutions. Optimum performance requires adherence to the provisions discussed here and in the Applications Information Section. This section covers an overview, a description of control modes (Extended Control Mode and Non-Extended Control Mode), and features. OVERVIEW The ADC10D1000/1500 uses a calibrated folding and interpolating architecture that achieves a high 9.1/9.0 Effective Number of Bits (ENOB). The use of folding amplifiers greatly reduces the number of comparators and power consumption. Interpolation reduces the number of front-end amplifiers required, minimizing the load on the input signal and further reducing power requirements. In addition to correcting other non-idealities, on-chip calibration reduces the INL bow often seen with folding architectures. The result is an extremely fast, high performance, low power converter. The analog input signal (which is within the converter's input voltage range) is digitized to ten bits at speeds of 200/200 MSPS to 1.0/1.5 GSPS, typical. Differential input voltages below negative full-scale will cause the output word to consist of all zeroes. Differential input voltages above positive full-scale will cause the output word to consist of all ones. Either of these conditions at the I- or Q-input will cause the Out-of-Range I-channel or Qchannel output (ORI or ORQ), respectively, to output a logic-high signal. In ECM, an expanded feature set is available via the Serial Interface. The ADC10D1000/1500 builds upon previous architectures, introducing a new AutoSync feature for multi-chip synchronization and increasing to 15-bit for gain and 12-bit plus sign for offset the independent programmable adjustment for each channel. Each channel has a selectable output demultiplexer which feeds two LVDS buses. If the 1:2 Demux Mode is selected, the output data rate is reduced to half the input sample rate on each bus. When Non-Demux Mode is selected, the output data rate on each channel is at the same rate as the input sample clock and only one 10-bit bus per channel is active. CONTROL MODES The ADC10D1000/1500 may be operated in one of two control modes: Non-extended Control Mode (Non-ECM) or Extended Control Mode (ECM). In the simpler Non-ECM (also sometimes referred to as Pin Control Mode), the user affects available configuration and control of the device through the control pins. The ECM provides additional configuration and control options through a serial interface and a set of 16 registers, most of which are available to the customer. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 45 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Non-Extended Control Mode In Non-extended Control Mode (Non-ECM), the Serial Interface is not active and all available functions are controlled via various pin settings. Non-ECM is selected by setting the ECE Pin to logic-high. Note that, for the control pins, "logic-high" and "logic-low" refer to VA and GND, respectively. Nine dedicated control pins provide a wide range of control for the ADC10D1000/1500 and facilitate its operation. These control pins provide DES Mode selection, Demux Mode selection, DDR Phase selection, execute Calibration, Calibration Delay setting, Power Down I-channel, Power Down Q-channel, Test Pattern Mode selection, and Full-Scale Input Range selection. In addition to this, two dual-purpose control pins provide for AC/DC-coupled Mode selection and LVDS output common-mode voltage selection. See Table 7 for a summary. Table 7. Non-ECM Pin Summary Pin Name Logic-Low Logic-High Floating DES Non-DES Mode DES Mode Not valid NDM Demux Mode Non-Demux Mode Not valid DDRPh 0 Mode 90 Mode Not valid Dedicated Control Pins CAL See Calibration Pin (CAL) Not valid CalDly Shorter delay Longer delay Not valid PDI I-channel active Power Down I-channel Power Down I-channel PDQ Q-channel active Power Down Q-channel Power Down Q-channel TPM Non-Test Pattern Mode Test Pattern Mode Not valid FSR Lower FS input Range Higher FS input Range Not valid Dual-purpose Control Pins VCMO AC-coupled operation Not allowed DC-coupled operation VBG Not allowed Higher LVDS common-mode voltage Lower LVDS common-mode voltage Dual Edge Sampling Pin (DES) The Dual Edge Sampling (DES) Pin selects whether the ADC10D1000/1500 is in DES Mode (logic-high) or NonDES Mode (logic-low). DES Mode means that a single input is sampled by both I- and Q-channels in a timeinterleaved manner and the other input is deactivated. One of the ADCs samples the input signal on the rising sampling clock edge (duty cycle corrected); the other ADC samples the input signal on the falling sampling clock edge (duty cycle corrected). In Non-ECM, only the I-input may be used for DES Mode, a.k.a. "DESI Mode". In ECM, the Q-input may be selected via the DEQ Bit (Addr: 0h, Bit: 6), a.k.a. "DESQ Mode". In ECM, both the Iand Q-channel inputs may be selected, a.k.a. "DESIQ Mode". To use this feature in ECM, use the DES bit in the Configuration Register (Addr: 0h; Bit: 7). See DES/Non-DES Mode for more information. Non-Demultiplexed Mode Pin (NDM) The Non-Demultiplexed Mode (NDM) Pin selects whether the ADC10D1000/1500 is in Demux Mode (logic-low) or Non-Demux Mode (logic-high). In Non-Demux Mode, the data from the input is produced at the sampled rate at a single 10-bit output bus. In Demux Mode, the data from the input is produced at half the sampled rate at twice the number of output buses. For Non-DES Mode, each I- or Q-channel will produce its data on one or two buses for Non-Demux or Demux Mode, respectively. For DES Mode, the Q-channel will produce its data on two or four buses for Non-Demux or Demux Mode, respectively. This feature is pin-controlled only and remains active during both Non-ECM and ECM. See Demux/Non-demux Mode for more information. 46 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Dual Data Rate Phase Pin (DDRPh) The Dual Data Rate Phase (DDRPh) Pin selects whether the ADC10D1000/1500 is in 0 Mode (logic-low) or 90 Mode (logic-high). The Data is always produced in DDR Mode on the ADC10D1000/1500. The Data may transition either with the DCLK transition (0 Mode) or halfway between DCLK transitions (90 Mode). The DDRPh Pin selects 0 Mode or 90 Mode for both the I-channel: DI- and DId-to-DCLKI phase relationship and for the Q-channel: DQ- and DQd-to-DCLKQ phase relationship. To use this feature in ECM, use the DPS bit in the Configuration Register (Addr: 0h; Bit: 14). See DDR Clock Phase for more information. Calibration Pin (CAL) The Calibration (CAL) Pin may be used to execute an on-command calibration or to disable the power-on calibration. The effect of calibration is to maximize the dynamic performance. To initiate an on-command calibration via the CAL pin, bring the CAL pin high for a minimum of tCAL_H input clock cycles after it has been low for a minimum of tCAL_L input clock cycles. Holding the CAL pin high upon power-on will prevent execution of the power-on calibration. In ECM, this pin remains active and is logically OR'd with the CAL bit. To use this feature in ECM, use the CAL bit in the Configuration Register (Addr: 0h; Bit: 15). See Calibration Feature for more information. Calibration Delay Pin (CalDly) The Calibration Delay (CalDly) Pin selects whether a shorter or longer delay time is present, after the application of power, until the start of the power-on calibration. The actual delay time is specified as tCalDly and may be found in Converter Electrical Characteristics - AC Electrical Characteristics. This feature is pin-controlled only and remains active in ECM. It is recommended to select the desired delay time prior to power-on and not dynamically alter this selection. See Calibration Feature for more information. Power Down I-channel Pin (PDI) The Power Down I-channel (PDI) Pin selects whether the I-channel is powered down (logic-high) or active (logiclow). The digital data output pins, DI and DId, (both positive and negative) are put into a high impedance state when the I-channel is powered down. Upon return to the active state, the pipeline will contain meaningless information and must be flushed. The supply currents (typicals and limits) are available for the I-channel powered down or active and may be found in Converter Electrical Characteristics - Power Supply Characteristics. The device should be recalibrated following a power-cycle of PDI (or PDQ). This pin remains active in ECM. In ECM, either this pin or the PDI bit (Addr: 0h; Bit: 11) in the Control Register may be used to power-down the I-channel. See Power Down for more information. Power Down Q-channel Pin (PDQ) The Power Down Q-channel (PDQ) Pin selects whether the Q-channel is powered down (logic-high) or active (logic-low). This pin functions similarly to the PDI pin, except that it applies to the Q-channel. The PDI and PDQ pins function independently of each other to control whether each I- or Q-channel is powered down or active. This pin remains active in ECM. In ECM, either this pin or the PDQ bit (Addr: 0h; Bit: 10) in the Control Register may be used to power-down the Q-channel. See Power Down for more information. Test Pattern Mode Pin (TPM) The Test Pattern Mode (TPM) Pin selects whether the output of the ADC10D1000/1500 is a test pattern (logichigh) or the converted analog input (logic-low). The ADC10D1000/1500 can provide a test pattern at the four output buses independently of the input signal to aid in system debug. In TPM, the ADC is disengaged and a test pattern generator is connected to the outputs, including ORI and ORQ. SeeTest Pattern Mode for more information. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 47 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Full-Scale Input Range Pin (FSR) The Full-Scale Input Range (FSR) Pin selects whether the full-scale input range for both the I- and Q-channel is higher (logic-high) or lower (logic-low). The input full-scale range is specified as VIN_FSR in Converter Electrical Characteristics - Analog Input/Output and Reference Characteristics. In Non-ECM, the full-scale input range for each I- and Q-channel may not be set independently, but it is possible to do so in ECM. The device must be calibrated following a change in FSR to obtain optimal performance. To use this feature in ECM, use the Configuration Registers (Addr: 3h and Bh). See Input Control and Adjust for more information. AC/DC-Coupled Mode Pin (VCMO) The VCMO Pin serves a dual purpose. When functioning as an output, it provides the optimal common-mode voltage for the DC-coupled analog inputs. When functioning as an input, it selects whether the device is ACcoupled (logic-low) or DC-coupled (floating). This pin is always active, in both ECM and Non-ECM. LVDS Output Common-mode Pin (VBG) The VBG Pin serves a dual purpose. When functioning as an output, it provides the bandgap reference. When functioning as an input, it selects whether the LVDS output common-mode voltage is higher (logic-high) or lower (floating). The LVDS output common-mode voltage is specified as VOS and may be found in Converter Electrical Characteristics - Digital Control and Output Pin Characteristics. This pin is always active, in both ECM and NonECM. Extended Control Mode In Extended Control Mode (ECM), most functions are controlled via the Serial Interface. In addition to this, several of the control pins remain active. See Table 10 for details. ECM is selected by setting the ECE Pin to logic-low. If the ECE Pin is set to logic-high (Non-ECM), then the registers are reset to their default values. So, a simple way to reset the registers is by toggling the ECE pin. Four pins on the ADC10D1000/1500 control the Serial Interface: SCS, SCLK, SDI and SDO. This section covers the Serial Interface. The Register Definitions are located at the end of the datasheet so that they are easy to find, see Register Definitions. The Serial Interface The ADC10D1000/1500 offers a Serial Interface that allows access to the sixteen control registers within the device. The Serial Interface is a generic 4-wire (optionally 3-wire) synchronous interface that is compatible with SPI type interfaces that are used on many micro-controllers and DSP controllers. Each serial interface access cycle is exactly 24 bits long. A register-read or register-write can be accomplished in one cycle. The signals are defined in such a way that the user can opt to simply join SDI and SDO signals in his system to accomplish a single, bidirectional SDI/O signal. A summary of the pins for this interface may be found in Table 8. See Figure 11 for the timing diagram and Converter Electrical Characteristics - AC Electrical Characteristics for timing specification details. Control register contents are retained when the device is put into power-down mode. Table 8. Serial Interface Pins Pin Name C4 SCS (Serial Chip Select bar) C5 SCLK (Serial Clock) B4 SDI (Serial Data In) A3 SDO (Serial Data Out) SCS: Each assertion (logic-low) of this signal starts a new register access, i.e. the SDI command field must be ready on the following SCLK rising edge. The user is required to de-assert this signal after the 24th clock. If the SCS is de-asserted before the 24th clock, no data read/write will occur. For a read operation, if the SCS is asserted longer than 24 clocks, the SDO output will hold the D0 bit until SCS is de-asserted. For a write operation, if the SCS is asserted longer than 24 clocks, data write will occur normally through the SDI input upon the 24th clock. Setup and hold times, tSCS and tHCS, with respect to the SCLK must be observed. SCS must be toggled in between register access cycles. 48 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 SCLK: This signal is used to register the input data (SDI) on the rising edge; and to source the output data (SDO) on the falling edge. The user may disable the clock and hold it at logic-low. There is no minimum frequency requirement for SCLK; see fSCLK in Converter Electrical Characteristics - AC Electrical Characteristics for more details. SDI: Each register access requires a specific 24-bit pattern at this input, consisting of a command field and a data field. When in read mode, the data field is high impedance in case the bidirectional SDI/O option is used. Setup and hold times, tSH and tSSU, with respect to the SCLK must be observed. SDO: This output is normally tri-stated and is driven only when SCS is asserted, the first 8 bits of command data have been received and it is a READ operation. The data is shifted out, MSB first, starting with the 8th clock's falling edge. At the end of the access, when SCS is de-asserted, this output is tri-stated once again. If an invalid address is accessed, the data sourced will consist of all zeroes. If it is a read operation, there will be a bus turnaround time, tBSU, from when the last bit of the command field was read in until the first bit of the data field is written out. Table 9 shows the Serial Interface bit definitions. Table 9. Command and Data Field Definitions Bit No. Name Comments 1 Read/Write (R/W) 1b indicates a read operation 0b indicates a write operation 2-3 Reserved Bits must be set to 10b 4-7 A<3:0> 16 registers may be addressed. The order is MSB first 8 X This is a "don't care" bit D<15:0> Data written to or read from addressed register 9-24 The serial data protocol is shown for a read and write operation in Figure 67 and Figure 68, respectively. 1 2 3 4 5 6 7 8 R/W 1 0 A3 A2 A1 A0 X 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 D5 D4 D3 D2 D1 D0 25 SCSb SCLK SDI SDO *Only required to be tri-stated in 3-wire mode. D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 Figure 67. Serial Data Protocol - Read Operation Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 49 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com 1 2 3 4 5 6 7 8 R/W 1 0 A3 A2 A1 A0 X 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 25 SCSb SCLK SDI SDO Figure 68. Serial Data Protocol - Write Operation FEATURES The ADC10D1000/1500 offers many features to make the device convenient to use in a wide variety of applications. Table 10 is a summary of the features available, as well as details for the control mode chosen. Table 10. Features and Modes Feature Non-ECM Control Pin Active in ECM ECM Default ECM State Input Control and Adjust AC/DC-coupled Mode Selection Selected via VCMO (Pin C2) Yes Not available N/A Input Full-scale Range Adjust Selected via FSR (Pin Y3) No Selected via the Config Reg (Addr: 3h and Bh) Mid FSR value Input Offset Adjust Setting Not available N/A Selected via the Config Reg (Addr: 2h and Ah) Offset = 0 mV LC Filter on Clock Not available N/A Selected via the Config Reg (Addr: Dh) LC Filter off DES/Non-DES Mode Selection Selected via DES (Pin V5) No Selected via the DES Bit (Addr: 0h; Bit: 7) Non-DES Mode Sampling Clock Phase Adjust Not available N/A Selected via the Config Reg (Addr: Ch and Dh) tAD adjust disabled VCMO Adjust Not available N/A Selected via the Config Reg (Addr: 1h) Default VCMO DDR Clock Phase Selection Selected via DDRPh (Pin W4) No Selected via the DPS Bit (Addr: 0h; Bit: 14) 0 Mode LVDS Differential Output Voltage Amplitude Selection Higher amplitude only N/A Selected via the OVS Bit (Addr: 0h; Bit: 13) Higher amplitude LVDS Common-Mode Output Voltage Amplitude Selection Selected via VBG (Pin B1) Yes Not available N/A Output Formatting Selection Offset Binary only N/A Selected via the 2SC Bit (Addr: 0h; Bit: 4) Offset Binary Test Pattern Mode at Output Selected via TPM (Pin A4) No Selected via the TPM Bit (Addr: 0h; Bit: 12) TPM disabled Output Control and Adjust 50 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Table 10. Features and Modes (continued) Feature Non-ECM Control Pin Active in ECM ECM Default ECM State Demux/Non-Demux Mode Selection Selected via NDM (Pin A5) Yes Not available N/A AutoSync Not available N/A Selected via the Config Reg (Addr: Eh) Master Mode, RCOut1/2 disabled DCLK Reset Not available N/A Selected via the Config Reg (Addr: Eh) DCLK Reset disabled On-command Calibration Selected via CAL (Pin D6) Yes Selected via the CAL Bit (Addr: 0h; Bit: 15) N/A (CAL = 0) Power-on Calibration Delay Selection Selected via CalDly (Pin V4) Yes Not available N/A Calibration Adjust Not available N/A Selected via the Config Reg (Addr: 4h) tCAL Power down I-channel Selected via PDI (Pin U3) Yes Selected via the PDI Bit (Addr: 0h; Bit: 11) I-channel operational Power down Q-channel Selected via PDQ (Pin V3) Yes Selected via the PDQ Bit (Addr: 0h; Bit: 10) Q-channel operational Calibration Power-Down "N/A" means "Not Applicable." Input Control and Adjust There are several features and configurations for the input of the ADC10D1000/1500 so that it may be used in many different applications. This section covers AC/DC-coupled Mode, input full-scale range adjust, input offset adjust, DES/Non-DES Mode, sampling clock phase adjust, an LC filter on the sampling clock, and VCMO Adjust. AC/DC-coupled Mode The analog inputs may be AC or DC-coupled. See AC/DC-Coupled Mode Pin (VCMO) for information on how to select the desired mode and DC-coupled Input Signals and AC-coupled Input Signals for applications information. Input Full-Scale Range Adjust The input full-scale range for the ADC10D1000/1500 may be adjusted via Non-ECM or ECM. In Non-ECM, a control pin selects a higher or lower value; see Full-Scale Input Range Pin (FSR). In ECM, the input full-scale range may be adjusted with 15-bits of precision. See VIN_FSR in Converter Electrical Characteristics - Analog Input/Output and Reference Characteristics for electrical specification details. Note that the higher and lower fullscale input range settings in Non-ECM correspond to the mid and min full-scale input range settings in ECM. It is necessary to execute an on-command calibration following a change of the input full-scale range. See Register Definitions for information about the registers. Input Offset Adjust The input offset adjust for the ADC10D1000/1500 may be adjusted with 12-bits of precision plus sign via ECM. See Register Definitions for information about the registers. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 51 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com DES/Non-DES Mode The ADC10D1000/1500 can operate in Dual-Edge Sampling (DES) or Non-DES Mode. The DES Mode allows for one of the ADC10D1000/1500's inputs to be sampled by both channels' ADCs. One ADC samples the input on the rising edge of the sampling clock and the other ADC samples the same input on the falling edge of the sampling clock. A single input is thus sampled twice per clock cycle, resulting in an overall sample rate of twice the sampling clock frequency, e.g. 2.0/3.0 GSPS with a 1.0/1.5 GHz sampling clock. See Dual Edge Sampling Pin (DES) for information on how to select the desired mode. Since DES Mode uses both I- and Q-channels to process the input signal, both channels must be powered up for the DES Mode to function properly. In Non-ECM, only the I-input may be used for the DES Mode input. In ECM, either the I- or Q-input may be selected by first using the DES bit (Addr: 0h, Bit 7) to select the DES Mode. The DEQ Bit (Addr: 0h, Bit: 6) is used to select the Q-input, but the I-input is used by default. Also, both I- and Q-inputs may be driven externally, i.e. DESIQ Mode, by using the DIQ bit (Addr: 0h, Bit 5). See THE ANALOG INPUTS for more information about how to drive the ADC in DES Mode. The DESIQ Mode results in the best bandwidth. In general, the bandwidth decreases from Non-DES Mode to DES Mode (specifically, DESI or DESQ) because both channels are sampling off the same input signal and nonideal effects introduced by interleaving the two channels lower the bandwidth. Driving both I- and Q-channels externally (DESIQ Mode) results in better bandwidth for the DES Mode because each channel is being driven, which reduces routing losses (increases bandwidth). In the DES Mode, the outputs must be carefully interleaved in order to reconstruct the sampled signal. If the device is programmed into the 1:4 Demux DES Mode, the data is effectively demultiplexed by 1:4. If the sampling clock is 1.0/1.5 GHz, the effective sampling rate is doubled to 2.0/3.0 GSPS and each of the 4 output buses has an output rate of 500 MSPS. All data is available in parallel. To properly reconstruct the sampled waveform, the four bytes of parallel data that are output with each DCLK must be correctly interleaved. The sampling order is as follows, from the earliest to the latest: DQd, DId, DQ, DI. See Figure 7. If the device is programmed into the Non-Demux DES Mode, two bytes of parallel data are output with each edge of the DCLK in the following sampling order, from the earliest to the latest: DQ, DI. See Figure 8. The performance of the ADC10D1000/1500 in DES Mode depends on how well the two channels are interleaved, i.e. that the clock samples either channel with precisely a 50% duty-cycle, each channel has the same offset (nominally code 511/512), and each channel has the same full-scale range. The ADC10D1000/1500 includes an automatic clock phase background adjustment in DES Mode to automatically and continuously adjust the clock phase of the I- and Q-channels, which also removes the need to adjust the clock phase setting manually. A difference exists in the typical offset between the I- and Q-channels, which can be removed via the offset adjust feature in ECM, to optimize DES Mode performance. If possible, it is recommended to use the Qinput for better DES Mode performance with no offset adjustment required. To adjust the I- or Q-channel offset, measure a histogram of the digital data and adjust the offset via the Control Register until the histogram is centered at code 511/512. Similarly, the full-scale range of each channel may be adjusted for optimal performance. Sampling Clock Phase Adjust The sampling clock (CLK) phase may be delayed internally to the ADC up to 825 ps in ECM. This feature is intended to help the system designer remove small imbalances in clock distribution traces at the board level when multiple ADCs are used, or to simplify complex system functions such as beam steering for phase array antennas. Additional delay in the clock path also creates additional jitter, so a clock jitter-cleaner is made available when using the sampling clock phase adjust, see LC Filter on Sampling Clock. Nevertheless, because the sampling clock phase adjust delays all clocks, including the DCLKs and output data, the user is strongly advised to use the minimal amount of adjustment and verify the net benefit of this feature in his system before relying on it. LC Filter on Sampling Clock A LC bandpass filter is available on the ADC10D1000/1500 sampling clock to clean jitter on the incoming clock. This feature is only available when the CLK phase adjust feature is also used. This feature was designed to minimize the dynamic performance degradation resulting from additional clock jitter as much as possible. It is available in ECM via the LCF (LC Filter) bits in the Control Register (Addr: Dh, Bits 7:0). 52 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 If the clock phase adjust feature is enabled, the sampling clock passes through additional gate delay, which adds jitter to the clock signal. The LC filter helps to remove this additional jitter, so it is only available when the clock phase adjust feature is also enabled. To enable both features, use SA (Addr: Dh, Bit 8). The LCF bits are thermometer encoded and may be used to set a filter center frequency ranging from 0.8 GHz to 1.5 GHz; see Table 11. Table 11. LC Filter Code vs. fc LCF(7:0) LCF(7:0) fc (GHz) 0 0000 0000b 1.5 1 0000 0001b 1.4 2 0000 0011b 1.3 3 0000 0111b 1.2 4 0000 1111b 1.1 5 0001 1111b 1.0 6 0011 1111b 0.92 7 0111 1111b 0.85 8 1111 1111b 0.8 The LC filter is a second-order bandpass filter, which has the following simulated bandwidth for a center frequency at 1GHz, see Table 12. Table 12. LC Filter Bandwidth vs. Level Bandwidth at [dB] -3 -6 -9 -12 Bandwidth [MHz] 135 235 360 525 VCMO Adjust The VCMO of the ADC10D1000/1500 is generated as a buffered version of the internal bandgap reference; see VCMO in Converter Electrical Characteristics - Analog Input/Output and Reference Characteristics. This pin provides an output voltage which is the optimal common-mode voltage for the input signal and should be used to set the common-mode voltage of the driving buffer. However, in order to accommodate larger signals at the analog inputs, the VCMO may be adjust to a lower value. From its typical default value, the VCMO may be lowered by approximately 200 mV via the Control Register 1h. See Register Definitions for more information. Adjusting the VCMO away from its optimal value will also degrade the dynamic performance; see ENOB vs. VCMO in Typical Performance Plots for a typical plot. The performance of the device, when using a VCMO other than the default value, is not specified. Output Control and Adjust There are several features and configurations for the output of the ADC10D1000/1500 so that it may be used in many different applications. This section covers DDR clock phase, LVDS output differential and common-mode voltage, output formatting, Demux/Non-demux Mode, and Test Pattern Mode. DDR Clock Phase The ADC10D1000/1500 output data is always delivered in Double Data Rate (DDR). With DDR, the DCLK frequency is half the data rate and data is sent to the outputs on both edges of DCLK; see Figure 69. The DCLKto-Data phase relationship may be either 0 or 90. For 0 Mode, the Data transitions on each edge of the DCLK. Any offset from this timing is tOSK; see Converter Electrical Characteristics - AC Electrical Characteristics for details. For 90 Mode, the DCLK transitions in the middle of each Data cell. Setup and hold times for this transition, tSU and tH, may also be found in Converter Electrical Characteristics - AC Electrical Characteristics. The DCLK-to-Data phase relationship may be selected via the DDRPh Pin in Non-ECM (see Dual Data Rate Phase Pin (DDRPh)) or the DPS bit in the Configuration Register (Addr: 0h; Bit: 14) in ECM. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 53 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Data DCLK 0 Mode DCLK 90 Mode Figure 69. DDR DCLK-to-Data Phase Relationship LVDS Output Differential Voltage The ADC10D1000/1500 is available with a selectable higher or lower LVDS output differential voltage. This parameter is VOD and may be found in Converter Electrical Characteristics - Digital Control and Output Pin Characteristics. The desired voltage may be selected via the OVS Bit (Addr: 0h, Bit 13); see Register Definitions for more information. LVDS Output Common-Mode Voltage The ADC10D1000/1500 is available with a selectable higher or lower LVDS output common-mode voltage. This parameter is VOS and may be found in Converter Electrical Characteristics - Digital Control and Output Pin Characteristics. See LVDS Output Common-mode Pin (VBG) for information on how to select the desired voltage. Output Formatting The formatting at the digital data outputs may be either offset binary or two's complement. The default formatting is offset binary, but two's complement may be selected via the 2SC Bit (Addr: 0h, Bit 4); see Register Definitions for more information. Demux/Non-demux Mode The ADC10D1000/1500 may be in one of two demultiplex modes: Demux Mode or Non-Demux Mode (also sometimes referred to as 1:1 Demux Mode). In Non-Demux Mode, the data from the input is simply output at the sampling rate at which it was sampled on one 10-bit bus. In Demux Mode, the data from the input is output at half the sampling rate, on twice the number of buses. See Figure 1. Demux/Non-Demux Mode may only be selected by the NDM pin; see Non-Demultiplexed Mode Pin (NDM). In Non-DES Mode, the output data from each channel may be demultiplexed by a factor of 1:2 (1:2 Demux Non-DES Mode) or not demultiplexed (NonDemux Non-DES Mode). In DES Mode, the output data from both channels interleaved may be demultiplexed (1:4 Demux DES Mode) or not demultiplexed (Non-Demux DES Mode). Test Pattern Mode The ADC10D1000/1500 can provide a test pattern at the four output buses independently of the input signal to aid in system debug. In Test Pattern Mode, the ADC is disengaged and a test pattern generator is connected to the outputs, including ORI and ORQ. The test pattern output is the same in DES Mode or Non-DES Mode. Each port is given a unique 10-bit word, alternating between 1's and 0's. When the part is programmed into the Demux Mode, the test pattern's order is described in Table 13. If the I- or Q-channel is powered down, the test pattern will not be output for that channel. 54 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Table 13. Test Pattern by Output Port in Demux Mode Time Qd Id Q I ORQ ORI T0 000h 001h 002h 004h 0b 0b T1 3FFh 3FEh 3FDh 3FBh 1b 1b T2 000h 001h 002h 004h 0b 0b T3 3FFh 3FEh 3FDh 3FBh 1b 1b T4 000h 001h 002h 004h 0b 0b T5 000h 001h 002h 004h 0b 0b T6 3FFh 3FEh 3FDh 3FBh 1b 1b T7 000h 001h 002h 004h 0b 0b T8 3FFh 3FEh 3FDh 3FBh 1b 1b T9 000h 001h 002h 004h 0b 0b T10 000h 001h 002h 004h 0b 0b T11 3FFh 3FEh 3FDh 3FBh 1b 1b T12 000h 001h 002h 004h 0b 0b T13 ... ... ... ... ... ... Comments Pattern Sequence n Pattern Sequence n+1 Pattern Sequence n+2 When the part is programmed into the Non-Demux Mode, the test pattern's order is described in Table 14. Table 14. Test Pattern by Output Port in Non-Demux Mode Time I Q ORI ORQ T0 001h 000h 0b 0b T1 001h 000h 0b 0b T2 3FEh 3FFh 1b 1b T3 3FEh 3FFh 1b 1b T4 001h 000h 0b 0b T5 3FEh 3FFh 1b 1b T6 001h 000h 0b 0b T7 3FEh 3FFh 1b 1b T8 3FEh 3FFh 1b 1b T9 3FEh 3FFh 1b 1b T10 001h 000h 0b 0b T11 001h 000h 0b 0b T12 3FEh 3FFh 1b 1b T13 3FEh 3FFh 1b 1b T14 ... ... ... ... Comments Pattern Sequence n Pattern Sequence n+1 Calibration Feature The ADC10D1000/1500 calibration must be run to achieve specified performance. The calibration procedure is exactly the same regardless of how it was initiated or when it is run. Calibration trims the analog input differential termination resistors, the CLK input resistor, and sets internal bias currents which affect the linearity of the converter. This minimizes full-scale error, offset error, DNL and INL, resulting in maximizing the dynamic performance, as measured by: SNR, THD, SINAD (SNDR) and ENOB. Calibration Control Pins and Bits Table 15 is a summary of the pins and bits used for calibration. See Ball Descriptions and Equivalent Circuits for complete pin information and Figure 10 for the timing diagram. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 55 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Table 15. Calibration Pins Pin/Bit Name Function D6 (Addr: 0h; Bit 15) CAL (Calibration) Initiate calibration V4 CalDly (Calibration Delay) Select calibration delay Addr: 4h Calibration Adjust Adjust calibration sequence and mode B5 CalRun (Calibration Running) Indicates while calibration is running C1/D2 Rtrim+/(Input termination trim resistor) External resistor used to calibrate analog and CLK inputs C3/D3 Rext+/(External Reference resistor) External resistor used to calibrate internal linearity How to Execute a Calibration Calibration may be initiated by holding the CAL pin low for at least tCAL_L clock cycles, and then holding it high for at least another tCAL_H clock cycles, as defined in Converter Electrical Characteristics - AC Electrical Characteristics. The minimum tCAL_L and tCAL_H input clock cycle sequences are required to ensure that random noise does not cause a calibration to begin when it is not desired. The time taken by the calibration procedure is specified as tCAL. The CAL Pin is active in both ECM and Non-ECM. However, in ECM, the CAL Pin is logically OR'd with the CAL Bit, so both the pin and bit are required to be set low before executing another calibration via either pin or bit. Power-on Calibration For standard operation, power-on calibration begins after a time delay following the application of power, as determined by the setting of the CalDly Pin and measured by tCalDly (see Converter Electrical Characteristics - AC Electrical Characteristics). This delay allows the power supply to come up and stabilize before the power-on calibration takes place. The best setting (short or long) of the CalDly Pin depends upon the settling time of the power supply. It is strongly recommended to set CalDly Pin (to either logic-high or logic-low) before powering the device on since this pin affects the power-on calibration timing. This may be accomplished by setting CalDly via an external 1k resistor connected to GND or VA. If the CalDly Pin is toggled while the device is powered-on, it can execute a calibration even though the CAL Pin/Bit remains logic-low. The power-on calibration will be not be performed if the CAL pin is logic-high at power-on. In this case, the calibration cycle will not begin until the on-command calibration conditions are met. The ADC10D1000/1500 will function with the CAL pin held high at power up, but no calibration will be done and performance will be impaired. If it is necessary to toggle the CalDly Pin during the system power up sequence, then the CAL Pin/Bit must be set to logic-high during the toggling and afterwards for 109 Sampling Clock cycles. This will prevent the power-on calibration, so an on-command calibration must be executed or the performance will be impaired. On-command Calibration In addition to the power-on calibration, it is recommended to execute an on-command calibration whenever the settings or conditions to the device are altered significantly, in order to obtain optimal parametric performance. Some examples include: changing the FSR via either ECM or Non-ECM, power-cycling either channel, and switching into or out of DES Mode. For best performance, it is also recommended that an on-command calibration be run 20 seconds or more after application of power and whenever the operating temperature changes significantly, relative to the specific system performance requirements. Due to the nature of the calibration feature, it is recommended to avoid unnecessary activities on the device while the calibration is taking place. For example, do not read or write to the Serial Interface or use the DCLK Reset feature while calibrating the ADC. Doing so will impair the performance of the device until it is re-calibrated correctly. Also, it is recommended to not apply a strong narrow-band signal to the analog inputs during calibration because this may impair the accuracy of the calibration; broad spectrum noise is acceptable. 56 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Calibration Adjust The calibration event itself may be adjusted, for sequence and mode. This feature can be used if a shorter calibration time than the default is required; see tCAL in Converter Electrical Characteristics - AC Electrical Characteristics. However, the performance of the device, when using a shorter calibration time than the default setting, is not specified. The calibration sequence may be adjusted via CSS (Addr: 4h, Bit 14). The default setting of CSS = 1b executes both RIN and RIN_CLK Calibration (using Rtrim) and internal linearity Calibration (using Rext). Executing a calibration with CSS = 0b executes only the internal linearity Calibration. The first time that Calibration is executed, it must be with CSS = 1b to trim RIN and RIN_CLK. However, once the device is at its operating temperature and RIN has been trimmed at least one time, it will not drift significantly. To save time in subsequent calibrations, trimming RIN and RIN_CLK may be skipped, i.e. by setting CSS = 0b. The mode may be changed, to save calibration execution time for the internal linearity Calibration. See tCAL in Converter Electrical Characteristics - AC Electrical Characteristics. Adjusting CMS(1:0) will select three different pre-defined calibration times. A larger amount of time will calibrate each channel more closely to the ideal values, but choosing shorter times will not significantly impact the performance. The fourth setting, CMS(1:0) = 11b, is not available. Read/Write Calibration Settings When the ADC performs a calibration, the calibration constants are stored in an array which is accessible via the Calibration Values register (Addr: 5h). To save the time which it takes to execute a calibration, tCAL, or if re-using a previous calibration result, these values can be read from and written to the register at a later time. For example, if an application requires the same input impedance, RIN, this feature can be used to load a previously determined set of values. For the calibration values to be valid, the ADC must be operating under the same conditions, including temperature, at which the calibration values were originally read from the ADC. To read calibration values from the SPI, do the following: 1. Set ADC to desired operating conditions. 2. Set SSC (Addr: 4h, Bit 7) to 1. 3. Power down both I- and Q-channels. 4. Read exactly 184 times the Calibration Values register (Addr: 5h). The register values are R0, R1, R2... R183. The contents of R<183:0> should be stored. 5. Power up I- and Q-channels to original setting. 6. Set SSC (Addr: 4h, Bit 7) to 0. 7. Continue with normal operation. To write calibration values to the SPI, do the following: 1. Set ADC to operating conditions at which Calibration Values were previously read. 2. Set SSC (Addr: 4h, Bit 7) to 1. 3. Power down both I- and Q-channels. 4. Write exactly 184 times the Calibration Values register (Addr: 5h). The registers should be written with stored register values R0, R1... R183. 5. Make two additional dummy writes of 0000h. 6. Power up I- and Q-channels to original setting. 7. Set SSC (Addr: 4h, Bit 7) to 0. 8. Continue with normal operation. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 57 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Calibration and Power-Down If PDI and PDQ are simultaneously asserted during a calibration cycle, the ADC10D1000/1500 will immediately power down. The calibration cycle will continue when either or both channels are powered back up, but the calibration will be compromised due to the incomplete settling of bias currents directly after power up. Therefore, a new calibration should be executed upon powering the ADC10D1000/1500 back up. In general, the ADC10D1000/1500 should be recalibrated when either or both channels are powered back up, or after one channel is powered down. For best results, this should be done after the device has stabilized to its operating temperature. Calibration and the Digital Outputs During calibration, the digital outputs (including DI, DId, DQ, DQd and OR) are set logic-low, to reduce noise. The DCLK runs continuously during calibration. After the calibration is completed and the CalRun signal is logiclow, it takes an additional 60 Sampling Clock cycles before the output of the ADC10D1000/1500 is valid converted data from the analog inputs. This is the time it takes for the pipeline to flush, as well as for other internal processes. Power Down On the ADC10D1000/1500, the I- and Q-channels may be powered down individually. This may be accomplished via the control pins, PDI and PDQ, or via ECM. In ECM, the PDI and PDQ pins are logically OR'd with the Control Register setting. See Power Down I-channel Pin (PDI) andPower Down Q-channel Pin (PDQ) for more information. Applications Information THE ANALOG INPUTS The ADC10D1000/1500 will continuously convert any signal which is present at the analog inputs, as long as a CLK signal is also provided to the device. This section covers important aspects related to the analog inputs including: acquiring the input, the reference voltage and FSR, out-of-range indication, AC/DC-coupled signals, and single-ended input signals. Acquiring the Input Data is acquired at the rising edge of CLK+ in Non-DES Mode and both the falling and rising edges of CLK+ in DES Mode. The digital equivalent of that data is available at the digital outputs a constant number of sampling clock cycles later for the DI, DQ, DId and DQd output buses, a.k.a. Latency, depending on the demultiplex mode which is selected. See tLAT in Converter Electrical Characteristics - AC Electrical Characteristics. In addition to the Latency, there is a constant output delay, tOD, before the data is available at the outputs. See tOD in Converter Electrical Characteristics - AC Electrical Characteristics and the Timing Diagrams. The output latency versus Demux/Non-Demux Mode is shown in Table 16 and Table 17, respectively. For DES Mode, note that the I- and Q-channel inputs are available in ECM, but only the I-channel input is available in Non-ECM. Table 16. Output Latency in Demux Mode 58 DES Mode Data Non-DES Mode Q-input* I-input DI I-input sampled with rise of CLK, 34 cycles earlier Q-input sampled with rise of CLK, 34 cycles earlier I-input sampled with rise of CLK, 34 cycles earlier DQ Q-input sampled with rise of CLK, 34 cycles earlier Q-input sampled with fall of CLK, 34.5 cycles earlier I-input sampled with fall of CLK, 34.5 cycles earlier DId I-input sampled with rise of CLK, 35 cycles earlier Q-input sampled with rise of CLK, 35 cycles earlier I-input sampled with rise of CLK, 35 cycles earlier DQd Q-input sampled with rise of CLK, 35 cycles earlier Q-input sampled with fall of CLK, 35.5 cycles earlier I-input sampled with fall of CLK, 35.5 cycles earlier Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Table 17. Output Latency in Non-Demux Mode Data Non-DES Mode DI DQ DES Mode Q-input* I-input I-input sampled with rise of CLK, 34 cycles earlier Q-input sampled with rise of CLK, 34 cycles earlier I-input sampled with rise of CLK, 34 cycles earlier Q-input sampled with rise of CLK, 34 cycles earlier Q-input sampled with rise of CLK, 34.5 cycles earlier I-input sampled with rise of CLK, 34.5 cycles earlier DId No output; high impedance. DQd No output; high impedance. *Available in ECM only. Driving the ADC in DES Mode The ADC10D1000/1500 can be configured as either a 2-channel, 1.0/1.5 GSPS device (Non-DES Mode) or a 1channel 2.0/3.0 GSPS device (DES Mode). When the device is configured in DES Mode, there is a choice for with which input to drive the single-channel ADC. These are the 3 options: DES - externally driving the I-channel input only. This is the default selection when the ADC is configured in DES Mode. It may also be referred to as "DESI" for added clarity. DESQ - externally driving the Q-channel input only. DESIQ - externally driving both the I- and Q-channel inputs. VinI+ and VinQ+ should be driven with the exact same signal. VinI- and VinQ- should be driven with the exact same signal, which is the differential complement to the one driving VinI+ and VinQ+. The input impedance for each I- and Q-input is 100 differential (or 50 single-ended), so the trace to each VinI+, VinI-, VinQ+, and VinQ- should always be 50 single-ended. If a single I- or Q-input is being driven, then that input will present a 100 differential load. For example, if a 50 single-ended source is driving the ADC, then a 1:2 balun will transform the impedance to 100 differential. However, if the ADC is being driven in DESIQ Mode, then the 100 differential impedance from the I-input will appear in parallel with the Q-input for a composite load of 50 differential and a 1:1 balun would be appropriate. See Figure 70 for an example circuit driving the ADC in DESIQ Mode. A recommended part selection is using the Mini-Circuits TC1-1-13MA+ balun with Ccouple = 0.22F. Ccouple 50: Source VINI+ 100: 1:1 Balun Ccouple VINI- Ccouple VINQ+ 100: Ccouple VINQADC1XD1X00 Figure 70. Driving DESIQ Mode Terminating Unused Analog Inputs In the case that only one channel is used in Non-DES Mode or that the ADC is driven in DESI or DESQ Mode, the unused analog input should be terminated to reduce any noise coupling into the ADC. See Table 18 for details. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 59 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Table 18. Unused Analog Input Recommended Termination Mode Power Down Coupling Recommended Termination Non-DES Yes AC/DC Tie Unused+ and Unused- to Vbg DES/ Non-DES No DC Tie Unused+ and Unused- to Vbg DES/ Non-DES No AC Tie Unused+ to Unused- FSR and the Reference Voltage The full-scale analog differential input range (VIN_FSR) of the ADC10D1000/1500 is derived from an internal 1.254V bandgap reference. In Non-ECM, this full-scale range has two settings controlled by the FSR Pin; see Full-Scale Input Range Pin (FSR). The FSR Pin operates on both I- and Q-channels. In ECM, the full-scale range may be independently set for each channel via Addr:3h and Bh with 15 bits of precision; see Register Definitions. The best SNR is obtained with a higher full-scale input range, but better distortion and SFDR are obtained with a lower full-scale input range. It is not possible to use an external analog reference voltage to modify the full-scale range, and this adjustment should only be done digitally, as described. A buffered version of the internal 1.254V bandgap reference voltage is made available at the VBG Pin for the user. The VBG pin can drive a load of up to 80 pF and source or sink up to 100 A. It should be buffered if more current than this is required. This pin remains as a constant reference voltage regardless of what full-scale range is selected and may be used for a system reference. VBG is a dual-purpose pin and it may also be used to select a higher LVDS output common-mode voltage; see LVDS Output Common-mode Pin (VBG). Out-Of-Range Indication Differential input signals are digitized to 10 bits, based on the full-scale range. Signal excursions beyond the fullscale range, i.e. greater than +VIN_FSR/2 or less than -VIN_FSR/2, will be clipped at the output. An input signal which is above the FSR will result in all 1's at the output and an input signal which is below the FSR will result in all 0's at the output. When the conversion result is clipped for the I-channel input, the Out-of-Range I-channel (ORI) output is activated such that ORI+ goes high and ORI- goes low while the signal is out of range. This output is active as long as accurate data on either or both of the buses would be outside the range of 000h to 3FFh. The Q-channel has a separate ORQ which functions similarly. Maximum Input Range The recommended operating and absolute maximum input range may be found in Operating Ratings and Absolute Maximum Ratings , respectively. Under the stated allowed operating conditions, each Vin+ and Vininput pin may be operated in the range from 0V to 2.15V if the input is a continuous 100% duty cycle signal and from 0V to 2.5V if the input is a 10% duty cycle signal. The absolute maximum input range for Vin+ and Vin- is from -0.15V to 2.5V. These limits apply only for AC input signals for which the input common mode voltage is properly maintained. AC-coupled Input Signals The ADC10D1000/1500 analog inputs require a precise common-mode voltage. This voltage is generated onchip when AC-coupling Mode is selected. See AC/DC-Coupled Mode Pin (VCMO) for more information about how to select AC-coupled Mode. In AC-coupled Mode, the analog inputs must of course be AC-coupled. For an ADC10D1000/1500 used in a typical application, this may be accomplished by on-board capacitors, as shown in Figure 71. For the ADC10D1000/1500RB, the SMA inputs on the Reference Board are directly connected to the analog inputs on the ADC10D1000/1500, so this may be accomplished by DC blocks (included with the hardware kit). When the AC-coupled Mode is selected, an analog input channel that is not used (e.g. in DES Mode) should be connected to AC ground, e.g. through capacitors to ground . Do not connect an unused analog input directly to ground. 60 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Ccouple VIN+ Ccouple VINVCMO ADC10D1000 Figure 71. AC-coupled Differential Input The analog inputs for the ADC10D1000/1500 are internally buffered, which simplifies the task of driving these inputs and the RC pole which is generally used at sampling ADC inputs is not required. If the user desires to place an amplifier circuit before the ADC, care should be taken to choose an amplifier with adequate noise and distortion performance, and adequate gain at the frequencies used for the application. DC-coupled Input Signals In DC-coupled Mode, the ADC10D1000/1500 differential inputs must have the correct common-mode voltage. This voltage is provided by the device itself at the VCMO output pin. It is recommended to use this voltage because the VCMO output potential will change with temperature and the common-mode voltage of the driving device should track this change. Full-scale distortion performance falls off as the input common mode voltage deviates from VCMO. Therefore, it is recommended to keep the input common-mode voltage within 100 mV of VCMO (typical), although this range may be extended to 150 mV (maximum). See VCMI in Converter Electrical Characteristics - Analog Input/Output and Reference Characteristics and ENOB vs. VCMI in Typical Performance Plots . Performance in AC- and DC-coupled Mode are similar, provided that the input common mode voltage at both analog inputs remains within 100 mV of VCMO. Single-Ended Input Signals The analog inputs of the ADC10D1000/1500 are not designed to accept single-ended signals. The best way to handle single-ended signals is to first convert them to differential signals before presenting them to the ADC. The easiest way to accomplish single-ended to differential signal conversion is with an appropriate balun-transformer, as shown in Figure 72. Ccouple 50: Source VIN+ 100: 1:2 Balun Ccouple VINADC10D1000 Figure 72. Single-Ended to Differential Conversion Using a Balun When selecting a balun, it is important to understand the input architecture of the ADC. The impedance of the analog source should be matched to the ADC10D1000/1500's on-chip 100 differential input termination resistor. The range of this termination resistor is specified as RIN in Converter Electrical Characteristics - Analog Input/Output and Reference Characteristics. THE CLOCK INPUTS The ADC10D1000/1500 has a differential clock input, CLK+ and CLK-, which must be driven with an ACcoupled, differential clock signal. This provides the level shifting to the clock to be driven with LVDS, PECL, LVPECL, or CML levels. The clock inputs are internally terminated to 100 differential and self-biased. This section covers coupling, frequency range, level, duty-cycle, jitter, and layout considerations. CLK Coupling The clock inputs of the ADC10D1000/1500 must be capacitively coupled to the clock pins as indicated in Figure 73. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 61 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Ccouple CLK+ Ccouple CLK- ADC10D1000 Figure 73. Differential Input Clock Connection The choice of capacitor value will depend on the clock frequency, capacitor component characteristics and other system economic factors. For example, on the ADC10D1000/1500RB, the capacitors have the value Ccouple = 4.7 nF which yields a highpass cutoff frequency, fc = 677.2 kHz. CLK Frequency Although the ADC10D1000/1500 is tested and its performance is specified with a differential 1.0/1.5 GHz sampling clock, it will typically function well over the input clock frequency range; see fCLK(min) and fCLK(max) in Converter Electrical Characteristics - AC Electrical Characteristics. Operation up to fCLK(max) is possible if the maximum ambient temperatures indicated are not exceeded. Operating at sample rates above fCLK(max) for the maximum ambient temperature may result in reduced device reliability and product lifetime. This is due to the fact that higher sample rates results in higher power consumption and die temperatures. If fCLK < 300 MHz, enable LFS in the Control Register (Addr: 0h, Bit 8). CLK Level The input clock amplitude is specified as VIN_CLK in Converter Electrical Characteristics - Sampling Clock Characteristics . Input clock amplitudes above the max VIN_CLK may result in increased input offset voltage. This would cause the converter to produce an output code other than the expected 511/512 when both input pins are at the same potential. Insufficient input clock levels will result in poor dynamic performance. Both of these results may be avoided by keeping the clock input amplitude within the specified limits of VIN_CLK. CLK Duty Cycle The duty cycle of the input clock signal can affect the performance of any A/D converter. The ADC10D1000/1500 features a duty cycle clock correction circuit which can maintain performance over the 20%-to-80% specified clock duty-cycle range. This feature is enabled by default and provides improved ADC clocking, especially in the Dual-Edge Sampling (DES) Mode. CLK Jitter High speed, high performance ADCs such as the ADC10D1000/1500 require a very stable input clock signal with minimum phase noise or jitter. ADC jitter requirements are defined by the ADC resolution (number of bits), maximum ADC input frequency and the input signal amplitude relative to the ADC input full scale range. The maximum jitter (the sum of the jitter from all sources) allowed to prevent a jitter-induced reduction in SNR is found to be tJ(MAX) = ( VIN(P-P)/ VFSR) x (1/(2(N+1) x x fIN)) (3) where tJ(MAX) is the rms total of all jitter sources in seconds, VIN(P-P) is the peak-to-peak analog input signal, VFSR is the full-scale range of the ADC, "N" is the ADC resolution in bits and fIN is the maximum input frequency, in Hertz, at the ADC analog input. tJ(MAX) is the square root of the sum of the squares (RSS) sum of the jitter from all sources, including: the ADC input clock, system, input signals and the ADC itself. Since the effective jitter added by the ADC is beyond user control, it is recommended to keep the sum of all other externally added jitter to a minimum. CLK Layout The ADC10D1000/1500 clock input is internally terminated with a trimmed 100 resistor. The differential input clock line pair should have a characteristic impedance of 100 and (when using a balun), be terminated at the clock source in that (100) characteristic impedance. 62 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 It is good practice to keep the ADC input clock line as short as possible, to keep it well away from any other signals and to treat it as a transmission line. Otherwise, other signals can introduce jitter into the input clock signal. Also, the clock signal can introduce noise into the analog path if it is not properly isolated. THE LVDS OUTPUTS The Data, ORI, ORQ, DCLKI and DCLKQ outputs are LVDS. The electrical specifications of the LVDS outputs are compatible with typical LVDS receivers available on ASIC and FPGA chips; but they are not IEEE or ANSI communications standards compliant due to the low +1.9V supply used on this chip. These outputs should be terminated with a 100 differential resistor placed as closely to the receiver as possible. This section covers common-mode and differential voltage, and data rate. Common-mode and Differential Voltage The LVDS outputs have selectable common-mode and differential voltage, VOS and VOD; see Converter Electrical Characteristics - Digital Control and Output Pin Characteristics. See Output Control and Adjust for more information. Selecting the higher VOS will also increase VOD slightly. The differential voltage, VOD, may be selected for the higher or lower value. For short LVDS lines and low noise systems, satisfactory performance may be realized with the lower VOD. This will also result in lower power consumption. If the LVDS lines are long and/or the system in which the ADC10D1000/1500 is used is noisy, it may be necessary to select the higher VOD. Output Data Rate The data is produced at the output at the same rate as it is sampled at the input. The minimum recommended input clock rate for this device is fCLK(MIN); see Converter Electrical Characteristics - AC Electrical Characteristics. However, it is possible to operate the device in 1:2 Demux Mode and capture data from just one 10-bit bus, e.g. just DI (or DId) although both DI and DId are fully operational. This will decimate the data by two and effectively halve the data rate. Terminating RSV Pins The RSV pins are used for internal purposes. They may be left unconnected and floating or connected as shown in Figure 74. VA 1 k5 RSV1+ To FPGA or Floating 1005 RSV1- To FPGA or Floating 1 k5 GND Figure 74. RSV Pin Connection This board configuration is recommended if the RSV pins are connected to FPGA input pins and must be forced to a known voltage. The value of the 100 resistor should not be changed, but the 1k resistors may be changed based upon the requirements of the specific FPGA. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 63 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Terminating Unused LVDS Output Pins If the ADC is used in Non-Demux Mode, then only the DI and DQ data outputs will have valid data present on them. The DId and DQd data outputs may be left not connected; if unused, they are internally tri-stated. Similarly, if the Q-channel is powered-down (i.e. PDQ is logic-high), the DQ data output pins, DCLKQ and ORQ should be left not connected. SYNCHRONIZING MULTIPLE ADC10D1000/1500S IN A SYSTEM The ADC10D1000/1500 has two features to assist the user with synchronizing multiple ADCs in a system; AutoSync and DCLK Reset. The AutoSync feature is new and designates one ADC10D1000/1500 as the Master ADC and other ADC10D1000/1500s in the system as Slave ADCs. The DCLK Reset feature performs the same function as the AutoSync feature, but is the first generation solution to synchronizing multiple ADCs in a system; it is disabled by default. For the application in which there are multiple Master and Slave ADC10D1000/1500s in a system, AutoSync may be used to synchronize the Slave ADC10D1000/1500(s) to each respective Master ADC10D1000/1500 and the DCLK Reset may be used to synchronize the Master ADC10D1000/1500s to each other. If the AutoSync or DCLK Reset feature is not used, see Table 19 for recommendations about terminating unused pins. Table 19. Unused AutoSync and DCLK Reset Pin Recommendation Pin(s) Unused termination RCLK+/- Do not connect. RCOUT1+/- Do not connect. RCOUT2+/- Do not connect. DCLK_RST+ Connect to GND via 1k resistor. DCLK_RST- Connect to VA via 1k resistor. AutoSync Feature AutoSync is a new feature which continuously synchronizes the outputs of multiple ADC10D1000/1500s in a system. It may be used to synchronize the DCLK and data outputs of one or more Slave ADC10D1000/1500s to one Master ADC10D1000/1500. Several advantages of this feature include: no special synchronization pulse required, any upset in synchronization is recovered upon the next DCLK cycle, and the Master/Slave ADC10D1000/1500s may be arranged as a binary tree so that any upset will quickly propagate out of the system. An example system is shown below in Figure 75 which consists of one Master ADC and two Slave ADCs. For simplicity, only one DCLK is shown; in reality, there is DCLKI and DCLKQ, but they are always in phase with one another. Master ADC10D1000 RCOut1 RCOut2 CLK DCLK Slave 2 ADC10D1000 RCLK RCOut1 RCOut2 CLK RCLK Slave 1 ADC10D1000 DCLK RCOut1 CLK RCLK RCOut2 DCLK CLK Figure 75. AutoSync Example 64 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 In order to synchronize the DCLK (and Data) outputs of multiple ADCs, the DCLKs must transition at the same time, as well as be in phase with one another. The DCLK at each ADC is generated from the CLK after some latency, plus tOD minus tAD. Therefore, in order for the DCLKs to transition at the same time, the CLK signal must reach each ADC at the same time. To tune out any differences in the CLK path to each ADC, the tAD adjust feature may be used. However, using the tAD adjust feature will also affect when the DCLK is produced at the output. If the device is in Demux Mode, then there are four possible phases which each DCLK may be generated on because the typical CLK = 1GHz and DCLK = 250 MHz for this case. The RCLK signal controls the phase of the DCLK, so that each Slave DCLK is on the same phase as the Master DCLK. The AutoSync feature may only be used via the Control Registers. DCLK Reset Feature The DCLK reset feature is available via ECM, but it is disabled by default. DCLKI and DCLKQ are always synchronized, by design, and do not require a pulse from DCLK_RST to become synchronized. The DCLK_RST signal must observe certain timing requirements, which are shown in Figure 9 of the Timing Diagrams. The DCLK_RST pulse must be of a minimum width and its deassertion edge must observe setup and hold times with respect to the CLK input rising edge. These timing specifications are listed as tPWR, tSR and tHR and may be found in Converter Electrical Characteristics - AC Electrical Characteristics. The DCLK_RST signal can be asserted asynchronously to the input clock. If DCLK_RST is asserted, the DCLK output is held in a designated state (logic-high) in Demux Mode; in Non-Demux Mode, the DCLK continues to function normally. Depending upon when the DCLK_RST signal is asserted, there may be a narrow pulse on the DCLK line during this reset event. When the DCLK_RST signal is de-asserted, there are tSYNC_DLY CLK cycles of systematic delay and the next CLK rising edge synchronizes the DCLK output with those of other ADC10D1000/1500s in the system. For 90 Mode (DDRPh = logic-high), the synchronizing edge occurs on the rising edge of CLK, 4 cycles after the first rising edge of CLK after DCLK_RST is released. For 0 Mode (DDRPh = logic-low), this is 5 cycles instead. The DCLK output is enabled again after a constant delay of tOD. For both Demux and Non-Demux Modes, there is some uncertainty about how DCLK comes out of the reset state for the first DCLK_RST pulse. For the second (and subsequent) DCLK_RST pulses, the DCLK will come out of the reset state in a known way. Therefore, if using the DCLK Reset feature, it is recommended to apply one "dummy" DCLK_RST pulse before using the second DCLK_RST pulse to synchronize the outputs. This recommendation applies each time the device or channel is powered-on. When using DCLK_RST to synchronize multiple ADC10D1000/1500s, it is required that the Select Phase bits in the Control Register (Addr: Eh, Bits 3,4) be the same for each Master ADC10D1000/1500. SUPPLY/GROUNDING, LAYOUT AND THERMAL RECOMMENDATIONS Power Planes All supply buses for the ADC should be sourced from a common linear voltage regulator. This ensures that all power buses to the ADC are turned on and off simultaneously. This single source will be split into individual sections of the power plane, with individual decoupling and connection to the different power supply buses of the ADC. Due to the low voltage but relatively high supply current requirement, the optimal solution may be to use a switching regulator to provide an intermediate low voltage, which is then regulated down to the final ADC supply voltage by a linear regulator. Please refer to the documentation provided for the ADC10D1000/1500RB for additional details on specific regulators that are recommended for this configuration. Power for the ADC should be provided through a broad plane which is located on one layer adjacent to the ground plane(s). Placing the power and ground planes on adjacent layers will provide low impedance decoupling of the ADC supplies, especially at higher frequencies. The output of a linear regulator should feed into the power plane through a low impedance multi-via connection. The power plane should be split into individual power peninsulas near the ADC. Each peninsula should feed a particular power bus on the ADC, with decoupling for that power bus connecting the peninsula to the ground plane near each power/ground pin pair. Using this technique can be difficult on many printed circuit CAD tools. To work around this, zero ohm resistors can be used to connect the power source net to the individual nets for the different ADC power buses. As a final step, the zero ohm resistors can be removed and the plane and peninsulas can be connected manually after all other error checking is completed. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 65 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Bypass Capacitors The general recommendation is to have one 100nF capacitor for each power/ground pin pair. The capacitors should be surface mount multi-layer ceramic chip capacitors similar to Panasonic part number ECJ-0EB1A104K. Ground Planes Grounding should be done using continuous full ground planes to minimize the impedance for all ground return paths, and provide the shortest possible image/return path for all signal traces. Power System Example The ADC10D1000/1500RB uses continuous ground planes (except where clear areas are needed to provide appropriate impedance management for specific signals), see Figure 76. Power is provided on one plane, with the 1.9V ADC supply being split into multiple zones or peninsulas for the specific power buses of the ADC. Decoupling capacitors are connected between these power bus peninsulas and the adjacent power planes using vias. The capacitors are located as close to the individual power/ground pin pairs of the ADC as possible. In most cases, this means the capacitors are located on the opposite side of the PCB to the ADC. Linear Regulator Cross Section Line Switching Regulator HV or Unreg Voltage Intermediate Voltage 1.9V ADC Main VTC VA VE VDR ADC Top Layer Signal 1 Dielectric 1 Ground 1 Dielectric 2 Signal 2 Dielectric 3 Ground 2 Dielectric 4 Signal 3 Dielectric 5 Power 1 Dielectric 6 Ground 3 Dielectric 7 Bottom Layer Signal X Figure 76. Power and Grounding Example Thermal Management The Heat Slug Ball Grid Array (NXA) package is a modified version of the industry standard plastic BGA (Ball Grid Array) package. Inside the package, a copper heat spreader cap is attached to the substrate top with exposed metal in the center top area of the package. This results in a 20% improvement (typical) in thermal performance over the standard plastic BGA package. 66 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 4JC_1 Copper Heat Slug Mold Compound Not to Scale Cross Section Line IC Die Substrate 4JC_2 Figure 77. HSBGA (NXA) Conceptual Drawing The center balls are connected to the bottom of the die by vias in the package substrate, Figure 77. This gives a low thermal resistance between the die and these balls. Connecting these balls to the PCB ground planes with a low thermal resistance path is the best way dissipate the heat from the ADC. These pins should also be connected to the ground plane via a low impedance path for electrical purposes. The direct connection to the ground planes is an easy method to spread heat away from the ADC. Along with the ground plane, the parallel power planes will provide additional thermal dissipation. The center ground balls should be soldered down to the recommended ball pads (See AN-1126). These balls will have wide traces which in turn have vias which connect to the internal ground planes, and a bottom ground pad/pour if possible. This ensures a good ground is provided for these balls, and that the optimal heat transfer will occur between these balls and the PCB ground planes. In spite of these package enhancements, analysis using the standard JEDEC JESD51-7 four-layer PCB thermal model shows that ambient temperatures must be limited to a max of 70C to ensure a safe operating junction temperature for the ADC10D1500. However, most applications using the ADC10D1500 will have a printed circuit board which is more complex than that used in JESD51-7. Typical circuit boards will have more layers than the JESD51-7 (eight or more), several of which will be used for ground and power planes. In those applications, the thermal resistance parameters of the ADC10D1500 and the circuit board can be used to determine the actual safe ambient operating temperature up to a maximum of 85C. Three key parameters are provided to allow for modeling and calculations. Because there are two main thermal paths between the ADC die and external environment, the thermal resistance for each of these paths is provided. JC1 represents the thermal resistance between the die and the exposed metal area on the top of the HSBGA package. JC2 represents the thermal resistance between the die and the center group of balls on the bottom of the HSBGA package. The final parameter is the allowed maximum junction temperature, which is 138C. In other applications, a heat sink or other thermally conductive path can be added to the top of the HSBGA package to remove heat. In those cases, JC1 can be used along with the thermal parameters for the heat sink or other thermal coupling added. Representative heat sinks which might be used with the ADC10D1000/1500 include the Cool Innovations p/n 3-1212XXG and similar products from other vendors. In many applications, the printed circuit board will provide the primary thermal path conducting heat away from the ADC package. In those cases, JC2 can be used in conjunction with printed circuit board thermal modeling software to determine the allowed operating conditions that will maintain the die temperature below the maximum allowable limit. Additional dissipation can be achieved by coupling a heat sink to the copper pour area on the bottom side of the printed circuit board. Typically, dissipation will occur through one predominant thermal path. In these cases, the following calculations can be used to determine the maximum safe ambient operating temperature: TJ = TA + PD x (JC+CA) 138C = TA + 3.98W x (JC+CA) For JC, the value for the primary thermal path in the given application environment should be used (JC1 or JC2). CA is the thermal resistance from the case to ambient, which would typically be that of the heat sink used. Using this relationship and the desired ambient temperature, the required heat sink thermal resistance can be found. Alternately, the heat sink thermal resistance can be used to find the maximum ambient temperature. For more complex systems, thermal modeling software can be used to evaluate the printed circuit board system and determine the expected junction temperature given the total system dissipation and ambient temperature. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 67 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com SYSTEM POWER-ON CONSIDERATIONS There are a couple important topics to consider associated with the system power-on event including configuration and calibration, and the Data Clock. Power-on, Configuration, and Calibration Following the application of power to the ADC10D1000/1500, several events must take place before the output from the ADC10D1000/1500 is valid and at full performance; at least one full calibration must be executed with the device configured in the desired mode. Following the application of power to the ADC10D1000/1500, there is a delay of tCalDly and then the Power-on Calibration is executed. This is why it is recommended to set the CalDly Pin via an external pull-up or pull-down resistor. Then, the state of that input will be determined at the same time that power is applied to the ADC and tCalDly will be a known quantity. For the purpose of this section, it is assumed that CalDly is set as recommended. The Control Bits or Pins must be set or written to configure the ADC10D1000/1500 in the desired mode. This must take place via either Extended Control Mode or Non-ECM (Pin Control Mode) before subsequent calibrations will yield an output at full performance in that mode. Some examples of modes include DES/NonDES Mode, Demux/Non-demux Mode, and Full-Scale Range. The simplest case is when device is in Non-ECM and the Control Pins are set by pull-up/down resistors, see Figure 78. For this case, the settings to the Control Pins ramp concurrently to the ADC voltage. Following the delay of tCalDly and the calibration execution time, tCAL, the output of the ADC10D1000/1500 is valid and at full performance. If it takes longer than tCalDly for the system to stabilize at its operating temperature, it is recommended to execute an on-command calibration at that time. Another case is when the FPGA writes to the Control Pins (Non-ECM) or to the SPI (ECM), see Figure 79. It is always necessary to comply with the Operating Ratings and Absolute Maximum ratings, i.e. the Control Pins may not be driven below the ground or above the supply, regardless of what the voltage currently applied to the supply is. Therefore, it is not recommended to write to the Control Pins or SPI before power is applied to the ADC10D1000/1500. As long as the FPGA has completed writing to the Control Pins or SPI, the Power-on Calibration will result in a valid output at full performance. Once again, if it takes longer than tCalDly for the system to stabilize at its operating temperature, it is recommended to execute an on-command calibration at that time. Due to system requirements, it may not be possible for the FPGA to write to the Control Pins or SPI before the Power-on Calibration takes place, see Figure 80. It is not critical to configure the device before the Power-on Calibration, but it is critical to realize that the output for such a case is not at its full performance. Following an On-command Calibration, the device will be at its full performance. Pull-up/down resistors set Control Pins Power to ADC CalDly ADC output valid Calibration Power-on Calibration On-command Calibration Figure 78. Power-on with Control Pins set by Pull-up/down Resistors 68 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 FPGA writes Control Pins Power to ADC ADC output valid CalDly Calibration Power-on Calibration On-command Calibration Figure 79. Power-on with Control Pins set by FPGA pre Power-on Cal FPGA writes Control Pins Power to ADC CalDly Calibration Power-on Calibration On-command Calibration Figure 80. Power-on with Control Pins set by FPGA post Power-on Cal Power-on and Data Clock (DCLK) Many applications use the DCLK output for a system clock. For the ADC10D1000/1500, each I- and Q-channel has its own DCLKI and DCLKQ, respectively. The DCLK output is always active, unless that channel is powereddown or the DCLK Reset feature is used while the device is in Demux Mode. As the supply to the ADC10D1000/1500 ramps, the DCLK also comes up, see this example from the ADC10D1000/1500RB: Figure 81. While the supply is too low, there is no output at DCLK. As the supply continues to ramp, DCLK functions intermittently with irregular frequency, but the amplitude continues to track with the supply. Much below the low end of operating supply range of the ADC10D1000/1500, the DCLK is already fully operational. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 69 ADC10D1000, ADC10D1500 www.ti.com mV SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Slope = 1.22V/ms 1900 1710 VA 1490 1210 660 635 520 DCLK 300 time Figure 81. Supply and DCLK Ramping RECOMMENDED SYSTEM CHIPS TI recommends these other chips including temperature sensors, clocking devices, and amplifiers in order to support the ADC10D1000/1500 in a system design. Temperature Sensor The ADC10D1000/1500 has an on-die temperature diode connected to pins Tdiode+/- which may be used to monitor the die temperature. TI also provides a family of temperature sensors for this application which monitor different numbers of external devices, see Table 20. Table 20. Temperature Sensor Recommendation Number of External Devices Monitored Recommended Temperature Sensor 1 LM95235 2 LM95213 4 LM95214 The temperature sensor (LM95235/13/14) is an 11-bit digital temperature sensor with a 2-wire System Management Bus (SMBus) interface that can monitor the temperature of one, two, or four remote diodes as well as its own temperature. It can be used to accurately monitor the temperature of up to one, two, or four external devices such as the ADC10D1000/1500, a FPGA, other system components, and the ambient temperature. The temperature sensor reports temperature in two different formats for +127.875C/-128C range and 0/255C range. It has a Sigma-Delta ADC core which provides the first level of noise immunity. For improved performance in a noise environment, the temperature sensor includes programmable digital filters for Remote Diode temperature readings. When the digital filters are invoked, the resolution for the Remote Diode readings increases to 0.03125C. For maximum flexibility and best accuracy, the temperature sensor includes offset registers that allow calibration of other diode types. Diode fault detection circuitry in the temperature sensor can detect the absence or fault state of a remote diode: whether D+ is shorted to the power supply, D- or ground, or floating. 70 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 In the following of a typical application, the LM95213 is used to monitor the temperature of an ADC10D1000/1500 as well as a FPGA, see Figure 82. 7 ADC10D1000 IE = IF D1+ 100 pF IR 5 IE = IF FPGA D- 100 pF 6 D2+ IR LM95213 Figure 82. Typical Temperature Sensor Application Clocking Device The clock source can be a PLL/VCO device such as the LMX2531LQxxxx family of products. The specific device should be selected according to the desired ADC sampling clock frequency. The ADC10D1000/1500RB uses the LMX2531LQ1510E, with the ADC clock source provided by the Aux PLL output. Other devices which may be considered based on clock source, jitter cleaning, and distribution purposes are the LMK01XXX, LMK02XXX, LMK03XXX and LMK04XXX product families. Amplifier The following amplifiers can be used for ADC10D1000/1500 applications which require DC coupled input or signal gain, neither of which can be provided with a transformer coupled input circuit: Table 21. Amplifier Recommendation Amplifier Bandwidth Brief features LMH6552 1.5 GHz Configurable gain LMH6553 900 MHz Output clamp and configurable gain LMH6554 2.5 GHz Configurable gain LMH6555 1.2 GHz Fixed gain Register Definitions Ten read/write registers provide several control and configuration options in the Extended Control Mode. These registers have no effect when the device is in the Non-extended Control Mode. Each register description below also shows the Power-On Reset (POR) state of each control bit. See Table 22 for a summary. For a description of the functionality and timing to read/write the control registers, see The Serial Interface. Table 22. Register Addresses A3 A2 A1 A0 Hex Register Addressed 0 0 0 0 0h Configuration Register 1 0 0 0 1 1h VCMO Adjust 0 0 1 0 2h I-channel Offset 0 0 1 1 3h I-channel FSR 0 1 0 0 4h Calibration Adjust 0 1 0 1 5h Reserved Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 71 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Table 22. Register Addresses (continued) 0 1 1 0 6h Reserved 0 1 1 1 7h Reserved 1 0 0 0 8h Reserved 1 0 0 1 9h Reserved 1 0 1 0 Ah Q-channel Offset 1 0 1 1 Bh Q-channel FSR 1 1 0 0 Ch Aperture Delay Coarse Adjust 1 1 0 1 Dh Aperture Delay Fine Adjust and LC Filter Adjust 1 1 1 0 Eh AutoSync 1 1 1 1 Fh Reserved Table 23. Configuration Register 1 Addr: 0h (0000b) POR state: 2000h Bit 15 14 13 12 11 10 9 8 7 6 5 4 Name CAL DPS OVS TPM PDI PDQ Res LFS DES DEQ DIQ 2SC POR 0 0 1 0 0 0 0 0 0 0 0 0 3 2 0 0 1 0 0 0 Res Bit 15 CAL: Calibration Enable. When this bit is set to 1b, an on-command calibration is initiated. This bit is not reset automatically upon completion of the calibration. Therefore, the user must reset this bit to 0b and then set it to 1b again to execute another calibration. This bit is logically OR'd with the CAL Pin; both bit and pin must be set to 0b before either is used to execute a calibration. Bit 14 DPS: DDR Phase Select. Set this bit to 0b to select the 0 Mode DDR Data-to-DCLK phase relationship and to 1b to select the 90 Mode. This bit has no effect when the device is in Non-Demux Mode. Bit 13 OVS: Output Voltage Select. This bit sets the differential voltage level for the LVDS outputs including Data, OR, and DCLK. 0b selects the lower level and 1b selects the higher level. See VOD in Converter Electrical Characteristics - Digital Control and Output Pin Characteristicsfor details. Bit 12 TPM: Test Pattern Mode. When this bit is set to 1b, the device will continually output a fixed digital pattern at the digital Data and OR outputs. When set to 0b, the device will continually output the converted signal, which was present at the analog inputs. See Test Pattern Mode for details about the TPM pattern. Bit 11 PDI: Power-down I-channel. When this bit is set to 0b, the I-channel is fully operational, but when it is set to 1b, the I-channel is powered-down. The I-channel may be powered-down via this bit or the PDI Pin, which is active, even in ECM. Bit 10 PDQ: Power-down Q-channel. When this bit is set to 0b, the Q-channel is fully operational, but when it is set to 1b, the Qchannel is powered-down. The Q-channel may be powered-down via this bit or the PDQ Pin, which is active, even in ECM. Bit 9 Reserved. Must be set to 0b. Bit 8 LFS: Low-Frequency Select. If the sampling clock (CLK) is at or below 300 MHz, set this bit to 1b. Bit 7 DES: Dual-Edge Sampling Mode select. When this bit is set to 0b, the device will operate in the Non-DES Mode; when it is set to 1b, the device will operate in the DES Mode. See DES/Non-DES Mode for more information. Bit 6 DEQ: DES Q-input select, a.k.a. DESQ Mode. When the device is in DES Mode, this bit can select the input that the device will operate on. The default setting of 0b selects the I-input and 1b selects the Q-input. Bit 5 DIQ: DES I- and Q-input, a.k.a. DESIQ Mode. When in DES Mode, setting this bit to 1b shorts the I- and Q-inputs. If the bit is left at its default 0b, the I- and Q-inputs remain electrically separate. To operate the device in DESIQ Mode, Bits<7:5> must be set to 101b. In this mode, both the I- and Q-inputs must be externally driven. Bit 4 2SC: Two's Complement output. For the default setting of 0b, the data is output in Offset Binary format; when set to 1b, the data is output in Two's Complement format. Bits 3:0 Reserved. Must be set to 0b. 72 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Table 24. VCMO Adjust Addr: 1h (0001b) Bit POR state: 2A00h 15 14 13 12 0 0 1 0 Name 11 10 9 8 7 1 0 1 0 0 Res POR 6 5 4 3 0 0 0 VCA(2:0) 0 2 1 0 0 0 Res 0 Bits 15:8 Reserved. Must be set as shown. Bits 7:5 VCA(2:0): VCMO Adjust. Adjusting from the default VCA(2:0) = 0d to VCA(2:0) = 7d decreases VCMO from it's typical value (see VCMO in Converter Electrical Characteristics - Analog Input/Output and Reference Characteristics) to 1.05V by increments of ~28.6 mV. Bits 4:0 Code VCMO 000 (default) VCMO 100 VCMO- 114 mV 111 VCMO- 200 mV Reserved. Must be set as shown. Table 25. I-channel Offset Adjust Addr: 2h (0010b) Bit POR state: 0000h 15 Name 14 13 Res POR 0 0 12 11 10 9 8 7 OS 0 6 5 4 3 2 1 0 0 0 0 0 0 OM(11:0) 0 0 0 0 0 0 0 0 Bits 15:13 Reserved. Must be set to 0b. Bit 12 OS: Offset Sign. The default setting of 0b incurs a positive offset of a magnitude set by Bits 11:0 to the ADC output. Setting this bet to 1b incurs a negative offset of the set magnitude. Bits 11:0 OM(11:0): Offset Magnitude. These bits determine the magnitude of the offset set at the ADC output (straight binary coding). The range is from 0 mV for OM(11:0) = 0d to 45 mV for OM(11:0) = 4095d in steps of ~11 V. Monotonicity is specified by design only for the 9 MSBs. Code Offset [mV] 0000 0000 0000 (default) 0 1000 0000 0000 22.5 1111 1111 1111 45 Table 26. I-channel Full Scale Range Adjust Addr: 3h (0011b) Bit 15 Name Res POR 0 POR state: 4000h 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 FM(14:0) 1 0 0 0 0 0 0 0 Bit 15 Reserved. Must be set to 0b. Bits 14:0 FM(14:0): FSR Magnitude. These bits increase the ADC full-scale range magnitude (straight binary coding.) The range is from 600 mV (0d) to 980 mV (32767d) with the default setting at 790 mV (16384d). Monotonicity is specified by design only for the 9 MSBs. The mid-range (low) setting in ECM corresponds to the nominal (low) setting in Non-ECM. A greater range of FSR values is available in ECM, i.e. FSR values above 790 mV. See VIN_FSR in Converter Electrical Characteristics - Analog Input/Output and Reference Characteristics for characterization details. Code FSR [mV] 000 0000 0000 0000 600 100 0000 0000 0000 (default) 790 111 1111 1111 1111 980 Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 73 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Table 27. Calibration Adjust Addr: 4h (0100b) POR state: DA7Fh Bit 15 14 Name Res CSS POR 1 1 13 12 0 1 11 10 1 0 Res 9 8 CMS(1:0) 1 7 6 5 4 1 1 1 SSC 0 0 3 2 1 0 1 1 1 Res 1 Bit 15 Reserved. Must be set as shown. Bit 14 CSS: Calibration Sequence Select. The default 1b selects the following calibration sequence: reset all previously calibrated elements to nominal values, do RIN Calibration, do internal linearity Calibration. Setting CSS = 0b selects the following calibration sequence: do not reset RIN to its nominal value, skip RIN calibration, do internal linearity Calibration. The calibration must be completed at least one time with CSS = 1b to calibrate RIN. Subsequent calibrations may be run with CSS = 0b (skip RIN calibration) or 1b (full RIN and internal linearity Calibration). Bits 13:10 Reserved. Must be set as shown. Bits 9:8 CMS(1:0): Calibration Mode Select. These bits affect the length of time taken to calibrate the internal linearity. See tCAL in Converter Electrical Characteristics - AC Electrical Characteristics. Bit 7 SSC: SPI Scan Control. Setting this control bit to 1b allows the calibration values, stored in Addr: 5h, to be read/written. When not reading/writing the calibration values, this control bit should left at its default 0b setting. Bits 6:0 Reserved. Must be set as shown. Table 28. Calibration Values Addr: 5h (0101b) Bit 15 POR state: XXXXh 14 13 12 11 10 9 Name 8 7 6 5 4 3 2 1 0 X X X X X X X SS(15:0) POR X Bits 15:0 X X X X X X X X SS(15:0): SPI Scan. When the ADC performs a self-calibration, the values for the calibration are stored in this register and may be read from/ written to it. Set SSC (Addr: 4h, Bit 7) to read/write. Table 29. Reserved Addr: 6h (0110b) Bit POR state: 1C70h 15 14 13 12 11 10 9 8 0 0 0 1 1 1 0 0 Name 7 6 5 4 3 2 1 0 0 1 1 1 0 0 0 0 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 Res POR Bits 15:0 Reserved. Must be set as shown. Table 30. Reserved Addr: 7h (0111b) Bit 15 POR state: 0000h 14 13 12 11 10 9 8 Name Res POR 0 Bits 15:0 74 0 0 0 0 0 0 0 Reserved. Must be set as shown. Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Table 31. Reserved Addr: 8h (1000b) Bit POR state: 0000h 15 14 13 12 11 10 9 8 0 0 0 0 0 0 0 0 Name POR 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 Res Bits 15:0 Reserved. Must be set as shown. Table 32. Reserved Addr: 9h (1001b) Bit POR state: 0000h 15 14 13 12 11 10 9 8 Name POR 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 5 4 3 2 1 0 0 0 0 0 0 Res 0 Bits 15:0 0 0 0 0 0 0 0 Reserved. Must be set as shown. Table 33. Q-channel Offset Adjust Addr: Ah (1010b) Bit Name POR POR state: 0000h 15 14 13 Res 0 0 12 11 10 9 8 7 6 0 0 0 0 0 0 OS 0 0 OM(11:0) 0 Bits 15:13 Reserved. Must be set to 0b. Bit 12 OS: Offset Sign. The default setting of 0b incurs a positive offset of a magnitude set by Bits 11:0 to the ADC output. Setting this bet to 1b incurs a negative offset of the set magnitude. Bits 11:0 OM(11:0): Offset Magnitude. These bits determine the magnitude of the offset set at the ADC output (straight binary coding). The range is from 0 mV for OM(11:0) = 0d to 45 mV for OM(11:0) = 4095d in steps of ~11 V. Monotonicity is specified by design only for the 9 MSBs. Code Offset [mV] 0000 0000 0000 (default) 0 1000 0000 0000 22.5 1111 1111 1111 45 Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 75 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com Table 34. Q-channel Full-Scale Range Adjust Addr: Bh (1011b) Bit 15 Name Res POR 0 POR state: 4000h 14 13 12 11 10 9 8 1 0 0 0 0 0 0 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 FM(14:0) 0 Bit 15 Reserved. Must be set to 0b. Bits 14:0 FM(14:0): FSR Magnitude. These bits increase the ADC full-scale range magnitude (straight binary coding.) The range is from 600 mV (0d) to 980 mV (32767d) with the default setting at 790 mV (16384d). Monotonicity is specified by design only for the 9 MSBs. The mid-range (low) setting in ECM corresponds to the nominal (low) setting in Non-ECM. A greater range of FSR values is available in ECM, i.e. FSR values above 790 mV. See VIN_FSR in Converter Electrical Characteristics - Analog Input/Output and Reference Characteristics for characterization details. Code FSR [mV] 000 0000 0000 0000 600 100 0000 0000 0000 (default) 790 111 1111 1111 1111 980 Table 35. Aperture Delay Coarse Adjust Addr: Ch (1100b) Bit POR state: 0004h 15 14 13 12 11 0 0 0 0 0 Name 10 9 8 7 6 5 4 0 0 0 0 0 CAM(11:0) POR 0 0 3 2 1 STA DCC 0 1 0 Res 0 0 Bits 15:4 CAM(11:0): Coarse Adjust Magnitude. This 12-bit value determines the amount of delay that will be applied to the input CLK signal. The range is 0 ps delay for CAM(11:0) = 0d to a maximum delay of 825 ps for CAM(11:0) = 2431d (95 ps due to PVT variation) in steps of ~340 fs. For code CAM(11:0) = 2432d and above, the delay saturates and the maximum delay applies. Additional, finer delay steps are available in register Dh. Either STA (Bit 3) or SA (Addr: Dh, Bit 8) must be selected to enable this function. Bit 3 STA: Select tAD Adjust. Set this bit to 1b to enable the tAD adjust feature, which will make both coarse and fine adjustment settings, i.e. CAM(11:0) and FAM(5:0), available. Bit 2 DCC: Duty Cycle Correct. This bit can be set to 0b to disable the automatic duty-cycle stabilizer feature of the chip. This feature is enabled by default. Bits 1:0 Reserved. Must be set to 0b. Table 36. Aperture Delay Fine Adjust and LC Filter Adjust Addr: Dh (1101b) Bit 15 POR state: 0000h 14 Name 13 12 11 10 FAM(5:0) POR 0 0 0 0 0 0 9 8 Res SA 0 0 7 6 5 4 3 2 1 0 0 0 0 LCF(7:0) 0 0 0 0 0 Bits 15:10 FAM(5:0): Fine Aperture Adjust Magnitude. This 6-bit value determines the amount of additional delay that will be applied to the input CLK when the Clock Phase Adjust feature is enabled via STA (Addr: Ch, Bit 3) or SA (Addr: Dh, Bit 8). The range is straight binary from 0 ps delay for FAM(5:0) = 0d to 2.3 ps delay for FAM(5:0) = 63d (300 fs due to PVT variation) in steps of ~36 fs. Bit 9 Reserved. Must be set to 0b. Bit 8 SA: Select tAD and LC filter Adjust. Set this bit to 1b to enable the tAD and LC filter adjust features. Using this bit is the same as enabling STA (Addr: Ch, Bit 3), but also enables the LC filter to clean the clock jitter. If SA is enabled, then the value of the STA bit is ignored. Bits 7:0 LCF(7:0): LC tank select Frequency. Use these bits to select the center frequency of the LC filter on the clock input. The range is from 0.8 GHz (255d) to 1.5 GHz (0d). Note that the tuning range is not binary encoded, and the eight bits are thermometer encoded, i.e. the mid value of 1.1 GHz tuning is achieved with LCF(7:0) = 0000 1111b. 76 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 ADC10D1000, ADC10D1500 www.ti.com SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 Table 37. AutoSync Addr: Eh (1110b) Bit POR state: 0003h 15 14 13 12 11 0 0 0 0 0 Name POR 10 9 8 7 6 0 0 0 0 DRC(9:0) 0 5 Res 0 4 3 SP(1:0) 0 0 2 1 0 ES DOC DR 0 1 1 Bits 15:6 DRC(9:0): Delay Reference Clock (9:0). These bits may be used to increase the delay on the input reference clock when synchronizing multiple ADCs. The minimum delay is 0s (0d) to 1000 ps (639d). The delay remains the maximum of 1000 ps for any codes above or equal to 639d. Bit 5 Reserved. Must be set to 0b. Bits 4:3 SP(1:0): Select Phase. These bits select the phase of the reference clock which is latched. The codes correspond to the following phase shift: 00 = 0 01 = 90 10 = 180 11 = 270 Bit 2 ES: Enable Slave. Set this bit to 1b to enable the Slave Mode of operation. In this mode, the internal divided clocks are synchronized with the reference clock coming from the master ADC. The master clock is applied on the input pins RCLK. If this bit is set to 0b, then the device is in Master Mode. Bit 1 DOC: Disable Output reference Clocks. Setting this bit to 0b sends a CLK/4 signal on RCOut1 and RCOut2. The default setting of 1b disables these output drivers. This bit functions as described, regardless of whether the device is operating in Master or Slave Mode, as determined by ES (Bit 2). Bit 0 DR: Disable Reset. The default setting of 1b leaves the DCLK_RST functionality disabled. Set this bit to 0b to enable DCLK_RST functionality. Table 38. Reserved Addr: Fh (1111b) Bit POR state: 000Ch 15 14 13 12 11 10 9 8 0 0 0 0 0 0 0 0 Name POR Bits 15:0 7 6 5 4 3 2 1 0 0 0 0 0 1 1 0 0 Res Reserved. This address is read only. Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 Submit Documentation Feedback 77 ADC10D1000, ADC10D1500 SNAS462Q - OCTOBER 2008 - REVISED MARCH 2013 www.ti.com REVISION HISTORY Changes from Revision P (March 2013) to Revision Q * 78 Page Changed layout of National Data Sheet to TI format .......................................................................................................... 71 Submit Documentation Feedback Copyright (c) 2008-2013, Texas Instruments Incorporated Product Folder Links: ADC10D1000 ADC10D1500 PACKAGE OPTION ADDENDUM www.ti.com 24-Nov-2013 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan Lead/Ball Finish MSL Peak Temp (2) (6) (3) Op Temp (C) Device Marking (4/5) ADC10D1000CIUT NRND BGA NXA 292 40 TBD Call TI Call TI -40 to 85 ADC10D1000 CIUT ADC10D1000CIUT/NOPB ACTIVE BGA NXA 292 40 Green (RoHS & no Sb/Br) NI/AU Level-3-250C-168 HR -40 to 85 ADC10D1000 CIUT ADC10D1500CIUT NRND BGA NXA 292 40 TBD Call TI Call TI -40 to 85 ADC10D1500 CIUT ADC10D1500CIUT/NOPB ACTIVE BGA NXA 292 40 Green (RoHS & no Sb/Br) NI/AU Level-3-250C-168 HR -40 to 85 ADC10D1500 CIUT (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. (4) There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device. (5) Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation of the previous line and the two combined represent the entire Device Marking for that device. (6) Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish value exceeds the maximum column width. Addendum-Page 1 Samples PACKAGE OPTION ADDENDUM www.ti.com 24-Nov-2013 Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 2 MECHANICAL DATA NXA0292A www.ti.com IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All semiconductor products (also referred to herein as "components") are sold subject to TI's terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI's terms and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily performed. TI assumes no liability for applications assistance or the design of Buyers' products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers' products and applications, Buyers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use of any TI components in safety-critical applications. In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI's goal is to help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and requirements. Nonetheless, such components are subject to these terms. No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties have executed a special agreement specifically governing such use. Only those TI components which TI has specifically designated as military grade or "enhanced plastic" are designed and intended for use in military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of non-designated products, TI will not be responsible for any failure to meet ISO/TS16949. Products Applications Audio www.ti.com/audio Automotive and Transportation www.ti.com/automotive Amplifiers amplifier.ti.com Communications and Telecom www.ti.com/communications Data Converters dataconverter.ti.com Computers and Peripherals www.ti.com/computers DLP(R) Products www.dlp.com Consumer Electronics www.ti.com/consumer-apps DSP dsp.ti.com Energy and Lighting www.ti.com/energy Clocks and Timers www.ti.com/clocks Industrial www.ti.com/industrial Interface interface.ti.com Medical www.ti.com/medical Logic logic.ti.com Security www.ti.com/security Power Mgmt power.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video RFID www.ti-rfid.com OMAP Applications Processors www.ti.com/omap TI E2E Community e2e.ti.com Wireless Connectivity www.ti.com/wirelessconnectivity Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright (c) 2013, Texas Instruments Incorporated