Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
“ZNR” Surge Absorbers, SMD Type
– 38 –
5.0
10.0
8.0
6.0
3.0
Occupied Space
Product
Land
■ Performance Characteristics
Characteristics Test Methods Specifi cations
Standard Test
Condition
Electrical measurements (initial/after tests) shall be conducted at
temperature of 5 to 35 °C, relative humidity of maximum 85 % ———
Varistor Voltage
The voltage between two terminals with the specifi ed measuring
current CmA DC applied is called Vc or VCmA. The measurement
should be made as fast as possible to avoid heat effects.
To meet the
specifi ed value.
Maximum Allowable
Voltage
The recommended maximum sinusoidal wave voltage (rms) or the
maximum DC voltage that can be applied continuously.
Clamping Voltage The maximum voltage between two terminals with the specifi ed
impulse current (8/20 μs).
Rated Power The maximum power that can be applied within the specifi ed
ambient temperature.
Maximum Energy Maximum energy of less than ±10 % of the varistor voltage
change when the standard impulse (2 ms) is applied one time.
Maximum
Peak Current
Maximum current of less than ±10 % of the varistor voltage change
when impulse current (8/20 μs) is applied twice continuously with
an interval of 5 minutes.
Temperature Co ef fi cient
of Varistor Volt age
VCmA at 85 °C – V
CmA at 25 °C ×1×100(%/°C)
VCmA at 25 °C 60 0 to –0.05 %/°C
Impulse Life (I)
The change of Vc shall be measured after the specifi ed impulse
is applied 10000 times continuously with an interval of 10 seconds
at room temperature.
Part Number Waveform Current
ERZVF□M220 to ERZVF□M680
ERZVF□M820 to ERZVF□M271
ERZVF□M331 to ERZVF□M471
8/20 μs
8/20 μs
8/20 μs
18 A
50 A
30 A
ΔVCmA/VCmA < ±10 %
Impulse Life (II)
The change of Vc shall be measured after the specifi ed impulse
is applied 100000 times continuously with an interval of 10
seconds at room temperature.
Part Number Waveform Current
ERZVF□M220 to ERZVF□M680
ERZVF□M820 to ERZVF□M271
ERZVF□M331 to ERZVF□M471
8/20 μs
8/20 μs
8/20 μs
12 A
35 A
20 A
ΔVCmA/VCmA < ±10 %
■ Recommendation Land Size
(Unit:mm)
Aug. 201201