REVISIONS
LTR DESCRIPTION DATE (YR-MO-DA) APPROVED
A
Add vendor CAGE 48726 to the 02XX device. Make correcti ons t o tables I and
II. Change name and address for CAGE U4637. Inactivate 01 device for new
design. Make changes to 6.4.
88-12-02
M. A. FRYE
B
Add vendors CAGE 69210 and 27014. Add case outlines T and U. Editorial
changes throughout.
91-11-04
M. A. FRYE
C
Changes in accordance with NOR 5962-R231-96.
96-09-30
R. MONNIN
D
Add radiation hardness requirem ents. Redrawn. -rrp
00-03-28
R. MONNIN
E
Add case outlines Y and Z. Make change to load regulation test for case
outline T as specified in table I - ro
02-05-14
R. MONNIN
F
Drawing updated to reflect current requirements. -rrp
09-12-02
C. SAFFLE
G Update drawing to current MIL-PRF-38535 requirements. -rrp 14-12-04 C. SAFFLE
THE ORIGINAL FIRST SHEET OF THIS DRAWING HAS BEEN REPLACED.
REV
SHEET
REV
SHEET
REV STATUS REV G G G G G G G G G G G G
OF SHE ETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12
PMIC N/A PREPARED BY
JOSEPH A. KER BY
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
http://www.landandmaritime.dla.mil
STANDARD
MICROCIRCUIT
DRAWING
THIS DRAWING IS AVAILABLE
FOR USE BY ALL
DEPARTMENTS
AND AGENCIES OF THE
DEPARTMENT OF DEFENSE
CHECKED BY
CH AR L ES E. BESORE
APPRO V ED BY
MICHAEL A. FRYE
MICROCIRCUI T, LINEAR, ADJUSTABLE
POSITI VE REGULAT O R, MONOLITHIC SILICON
DRAWING APPROVAL DATE
87-11-18
AMSC N/A
REVISION LEVEL
G SIZE
A CAGE CODE
67268
5962-87675
SHEET 1 OF 12
DSCC FORM 2233
APR 97 5962-E084-15
1. SCOPE
1.1 Scope. This drawing describes device requirements for MIL-STD-883 compliant, non-JAN class level B microcircuits in
accordance with MIL-PRF-38535, appendix A.
1.2 Part or Identifying Number (PIN). The complete PIN is as shown in the following example:
5962 R 87675 01 X A
Federal RHA Device Case Lead
stock class designator type outline finish
designator (see 1.2.1) (see 1.2. 2) (see 1.2. 3) (see 1.2.4)
\ /
\/
Drawing number
1.2.1 Dev ice ty pe(s). The device type(s) identify the circuit function as follows:
Device type Generic number Circuit function
01 150 3.0 A positive regulator, adjustable
02 150A 3.0 A positive regulator, adjustable
1.2.2 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows:
Outline letter Descriptive designator Terminals Package sty le
T See figure 1 3 TO-257 Single row flange mount with
non-isolated tab and glass sealed
U See figure 1 3 TO-257 Single row flange mount with
isolated tab and glass sealed
X MBFM1-P2 2 TO-3 Flange mount
Y See figure 1 3 Flange mount, glass sealed with
gull wing leads
Z CBCC1-N3 3 Bottom terminal chip carrier
1.2.3 Lead finish. The lead finish is as specified in MIL-PRF-38535, appendix A.
1.3 Absol ute maximum rating s.
Input to output voltage differential ............................................................... 35 V
Storage temperature range ......................................................................... -65°C to +150°C
Lead temperature (soldering, 10 seconds) .................................................. +300°C
Power dissipation (PD) ................................................................................ Internally lim ited 1/
Junction temperature (TJ) ............................................................................ +150°C
Thermal resistance, junction-to-case (θJC):
Case T ..................................................................................................... 3.5°C/W
Case U ..................................................................................................... 4.2°C/W
Case X ..................................................................................................... 1.5°C/W
Case Y ...................................................................................................... 6.4°C/W
Case Z ..................................................................................................... 3.7°C/W
______
1/ Pow er dissipation is guaranteed at 30 W up to 15 V input-output differential. Above 15 V, input-output differential power
dissipation is limited by device internal protection circuitry.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-87675
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
G SHEET 2
DSCC FORM 2234
APR 97
1.4 Recom me nded operati ng cond it io ns.
Ambient operating temperature range (TA) .................................................. -55°C to +125°C
1.5 Radiation features:
Maximum total dose available (dose rate = 50 300 rads(Si) / s) ................ 1 00 Krads (Si) 2/
2. APPLICABLE DOCUMENTS
2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part
of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the
solicitati on or cont rac t.
DEPARTMENT OF DEFENSE SPECIFICATION
MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for.
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-883 - Test Method Standard Microcircuits.
MIL-STD-1835 - Interface Standard Electronic Component Case Outlines.
DEPARTMENT OF DEFENSE HANDBOOKS
MIL-HDBK-103 - List of Standard Microcircuit Drawings.
MIL-HDBK-780 - Standard Microcircuit Drawings.
(Copies of these documents are available online at http://quicksearch.dla.mil/ or from the Standardization Document Order
Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
2.2 Order of prece den ce. In the event of a conflict between the text of this drawing and the references cited herein, the text
of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
3. REQUIREMENTS
3.1 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-38535, appendix A for non-
JAN class level B devices and as specified herein. Product built to this drawing that is produced by a Qualified Manufacturer
Listing (QML) certified and qualified manufacturer or a manufacturer who has been granted transitional certification to MIL-
PRF-38535 may be processed as QML product in accordance with the manufacturers approved program plan and qualifying
activity approval in accordance with MIL-PRF-38535. This QML flow as documented in the Quality Management (QM) plan
may make modifications to the requirements herein. These modifications shall not affect form, fit, or function of the device.
These modifications shall not affect the PIN as described herein. A "Q" or "QML" certification mark in accordance with MIL-
PRF-38535 is required to identify when the QML flow option is used. This drawing has been modified to allow the
manufacturer to use the alternate die/fabrication requirements of paragraph A.3.2.2 of MIL-PRF-38535 or other alternative
approved by the qualif ying activit y .
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified
in MIL-PRF-38535, appendix A and herein.
3.2.1 Case outline. The case outline shall be in accordance with 1.2.2 herein.
3.2.2 Terminal connections. The terminal con nec tio ns shall be as specified on figure 2.
______
2/ These parts may be dose rate sensitive in a space environment and may demonstrate enhanced low dose rate effects.
Radiation end point limits for the noted parameters are guaranteed only for the conditions specified in MIL-STD-883,
method 1019, condition A.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-87675
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
G SHEET 3
DSCC FORM 2234
APR 97
3.2.3 Radia tion ex posure cir cu it . The radiation exposure circuit shall be maintained by the manufacturer under docum ent
revision level control and shall be made available to the preparing and acquiring activity upon request.
3.3 Electr ica l perf or man ce ch aract er is tic s. Unless otherwise specified herein, the electrical performance characteristics are
as specified in table I and shall apply over the full ambient operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical
tests for each subgr oup are described in table I.
3.5 Marking. Marking shall be in accordance with MIL-PRF-38535, appendix A. The part shall be marked with the PIN
listed in 1.2 herein. In addition, the manufacturer's PIN may also be marked. In addition, the manufacturer's PIN may also be
marked. For packages where marking of the entire SMD PIN number is not feasible due to space limitations, the manufacturer
has the option of not marking the "5962-" on the device.
3.5.1 Certification/compliance mark. A compliance indicator “C” shall be marked on all non-JAN devices built in compliance
to MIL-PRF-38535, appendix A. The compliance indicator “C” shall be replaced with a "Q" or "QML" certification mark in
accordance with MIL-PRF-38535 to identify when the QML flow option is used. For product built in accordance with A.3.2.2 of
MIL-PRF-38535, or as modified in the manufacturer’s QM plan, the “QD” certification mark shall be used in place of the "Q" or
"QM L" certificati on mar k.
3.6 Certif i cate of compli an ce. A certificate of compliance shall be required from a manufacturer in order to be listed as an
approved sour ce of supply in M IL-HDBK-103 (see 6.6 herein). The certificate of compliance submitted to DLA Land and
Maritime -VA prior to listing as an approved source of supply shall affirm that the manufacturer's product meets the
requireme nts of M IL-PRF-38535, appendix A and the requirements herein.
3.7 Certif i cate of conform anc e. A certificate of conformance as required in MIL-PRF-38535, appendix A shall be provided
with each lot of microcir cui ts d eliv ered to t his drawing.
3.8 Notification of change. Notification of change to DLA Land and Maritime -VA shall be required for any change that
affects this drawing.
3.9 Verification and review. DLA Land and Maritime, DLA Land and Maritime's agent, and the acquiring activity retain the
option to review the manufacturer's facility and applicable required documentation. Offshore documentation shall be made
available onshore at the option of the reviewer.
4. VERIFICATION
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535,
appendix A.
4.2 Screening. Screening shall be in accordance with method 5004 of MIL-STD-883, and shall be conducted on all devices
prior to quality conformance inspection. The following additional criteria shall apply:
a. Burn-in test, method 1015 of MIL-STD-883.
(1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify
the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method
1015 of MIL-STD-883.
(2) TA = +125°C, minimum.
b. Interim and final electrical test parameters shall be as specified in table II herein, except interim electrical parameter
tests prior to burn-in are optional at the discretion of the manufacturer.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-87675
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
G SHEET 4
DSCC FORM 2234
APR 97
TABLE I. Electrical performance characteristics.
Test Symbol Conditions 1/ 2/ 3/
-55°C TA +125°C
unless otherw ise sp ecif ied
Group A
subgroups
Device
type
Limits Unit
Min
Max
Reference voltage
VREF IOUT = 10 mA, TA = +25°C
1
01
1.20
1.30
V
IOUT = 10 mA, TA = +25°C
1
02
1.238
1.262
M,D,P,L,R
1
1.238
1.262
3.0 V (VIN – VOUT) 35 V
10 mA IOUT 3.0 A,
P 30 W 4/
1,2,3
01
1.20
1.30
3.0 V (VIN – VOUT) 35 V
10 mA IOUT 3.0 A,
P 30 W 4/
1,2,3
02
1.225
1.270
M,D,P,L,R
1
1.225
1.270
Line regulation 5/
VOUT/
VIN
3.0 V (VIN – VOUT) 35 V
IOUT = 10 mA, TJ = +25°C
1
01,02
0.01
%/V
M,D,P,L,R
1
02
0.01
3.0 V (VIN – VOUT) 35 V
IOUT = 10 mA
2,3
01,02
0.05
Load regulation 5/ 6/
VOUT/
IOUT
10 mA IOUT 3.0 A
VOUT 5.0 V,
TJ = +25°C
Cases
X and Z
1
01,02
15
mV
Cases
T, U,
and Y
17.5
M,D,P,L,R
Case U
1
02
17.5
10 mA IOUT 3.0 A,
VOUT 5.0 V
2,3
01,02
50
10 mA IOUT 3.0 A
VOUT 5.0 V,
TJ = +25°C
Cases
X and Z
1
0.3
%
Cases
T, U,
and Y
0.35
M,D,P,L,R
Case U
1
02
0.35
10 mA IOUT 3.0 A,
VOUT 5.0 V
2,3
01,02
1.0
See footnotes at end of table.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-87675
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
G SHEET 5
DSCC FORM 2234
APR 97
TABLE I. Electrical performance characteristics - Continued.
Test Symbol Conditions 1/ 2/ 3/
-55°C TA +125°C
unless otherw ise sp eci fied
Group A
subgroups
Device
type
Limits Unit
Min
Max
Thermal regulation
----
20 ms pulse, TA = +25°C
1
01,02
0.01
%/W
M,D,P,L,R
1
02
0.01
Ripple rejection 7/
VIN/
VREF
VOUT = 10 V, f = 120 Hz,
CADJ = 10 µF
4,5,6
01,02
66
dB
M,D,P,L,R
4
02
66
Adjust pin current
IADJ
1,2,3
01,02
100
µA
M,D,P,L,R
1
02
100
Adjust pin current
change
IADJ 10 mA IOUT 3.0 A,
IOUT = 10 mA,
3.0 V (VIN – VOUT) 35 V
1,2,3
01,02
5.0
µA
M,D,P,L,R
1
02
5.0
Minimum load curre nt
IMIN (VIN – VOUT) = 35 V
1,2,3
01,02
5.0
mA
M,D,P,L,R
1
02
5.0
Current limit
ICL
or (VIN – VOUT) 10 V
1,2,3
01,02
3.0
A
M,D,P,L,R
1
02
3.0
ISC (VIN – VOUT) = 30 V
1,2,3
01,02
0.3
M,D,P,L,R
1
02
0.3
Temperature 7/
stability VOUT/
T -55°C TJ +125°C
1,2,3
02
2.0
%
M,D,P,L,R
1
2.0
Long term stability 7/
VOUT/
T TA = +125°C,
t = 1000 hours
2
01,02
1.0
%
See footnotes at end of table.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-87675
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
G SHEET 6
DSCC FORM 2234
APR 97
TABLE I. Electrical performance characteristics - Continued.
1/ Devices supplied to this drawing will meet all levels M, D, P, L, R of irradiation. However, this device is only tested at
the ‘R’ level. Pre and Post irradiation values are identical unless otherwise specified in table I. When performing post
irradiation electrical measurements for any RHA level, TA = +25°C.
2/ These parts may be dose rate sensitiv e in a space environment and may demonstrate enhanced low dose rate effects.
Radiation end point limits for the noted parameters are guaranteed only for the conditions specified in MIL-STD-883,
method 1019, condition A.
3/ Unles s otherwise specified, these specifications apply for (VIN – VOUT) = 5.0 V and IOUT = 1.5 A. Although power
dissipation is internally limited, these characteristics are applicable for power dissipation up to 30 W.
4/ Cases T, U, Y, and Z: For output voltage readings not taken at the case, decrease minimum limits by IOUT (10 m) per
inch of case to measurement-point lead length, e.g., 15 mV per inch at 1.5 A and 30 mV per inch at 3.0 A.
5/ Regulation is measured at a constant junction temperature using a pulse technique. Changes in output voltage due to
heating effects are covered under the specification for thermal regulation.
6/ Cases T, U, Y, and Z: For load regulation readings not taken at the case, increase maximum limits by IOUT (10 m) per
inch of case to measurement-point lead length, e.g., 30 mV per inch at 3.0 A.
7/ Guaranteed, if not tested, to the limits specified.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-87675
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
G SHEET 7
DSCC FORM 2234
APR 97
Case outlines T and U
Letter
Inches
Millimeters
Min
Max
Min
Max
A
.190
.200
4.83
5.08
A1
.035
.045
0.89
1.14
A2
.120 BSC
3.05 BSC
φb
.025
.035
0.64
0.89
D
.645
.665
16.38
16.89
D1
.410
.430
10.41
10.92
D3
.000
.065
0.00
1.65
e
.100 BSC
2.54 BSC
E
.410
.422
10.41
10.71
L
.500
.750
12.70
19.05
O
.527
.537
13.39
16.64
φP
.140
.150
3.56
3.81
NOTE:
The U.S. government preferred system of measurement is the metric SI system. However, since this item was
originally designed using inch-pound units of measurement, in the event of conflict between the metric and
inch-pound units, the inch-pound units shall take precedence.
FIGURE 1. Case outline.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-87675
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
G SHEET 8
DSCC FORM 2234
APR 97
Case outline Y
Symbol
Inches
Millimeters
Min
Max
Min
Max
A
.190
.210
4.83
5.33
b
---
.030
---
0.76
D
.410
.430
10.41
10.92
D1
.580
.610
14.73
15.49
e
---
.100
---
2.54
e1
---
.200
---
5.08
E
.410
.420
10.41
10.67
L1
.090
.110
2.29
2.79
L
.115
.125
2.92
3.18
N
3
3
NOTE:
The U.S. government preferred system of measurement is the metric SI system. However, since this item was
originally designed using inch-pound units of measurement, in the event of conflict between the metric and
inch-pound units, the inch-pound units shall take precedence.
FIGURE 1. Case outlineContinued.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-87675
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
G SHEET 9
DSCC FORM 2234
APR 97
Device types
01 and 02
01
01
Case outlines
T
U
X
Y
Z
Terminal
number
Terminal symbo l
1
ADJUST
ADJUST
ADJUST
ADJUST
INPUT
2
OUTPUT
OUTPUT
INPUT
OUTPUT
ADJUST
3
INPUT
INPUT
OUTPUT
(CASE)
INPUT
OUTPUT
4
OUTPUT
NC
---
---
---
NC = No connection
FIGURE 2. Terminal connections.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-87675
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
G SHEET 10
DSCC FORM 2234
APR 97
4.3 Quality conformance insp ecti on. Quality conformance inspection shall be in accordance with method 5005 of MIL-STD-
883 including groups A, B, C, and D inspections. The following additional criteria shall apply.
4.3.1 Gro up A inspe ctio n.
a. T ests shal l be as specified in table I I herein.
b. Subgroups 7, 8, 9, 10 and 11 in table I, method 5005 of MIL-STD-883 shall be omitted.
4.3.2 Groups C and D inspections.
a. End-point electric al para meters shall be as specified in table II here in.
b. Steady-state life test conditions, method 1005 of MIL-STD-883.
(1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision
level control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in
method 1005 of MIL-STD-883.
(2) TA = +125°C, minimum.
(3) Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
TABLE II. Electrical test requirements.
MIL-STD-883 test requirements
Subgroups
(in accordance with
MIL-STD-883, method 5005,
table I)
Interim electrical parameters
(method 5004) 1
Final electrical test parameters
(method 5004) 1*, 2, 3
Group A test requirements
(method 5005) 1, 2, 3, 4**, 5**, 6**
Groups C and D end-point
electrical parameters
(method 5005)
1
Group E end-point electri cal
parameters (method 5005)
1, 4
* PDA applies to subgroup 1.
** Subgroups 4, 5, and 6, if not tested, shall be guaranteed to the
limits specified in table I.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-87675
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
G SHEET 11
DSCC FORM 2234
APR 97
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535, appendix A.
6. NOTES
6.1 Inten ded use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications
(original equ ipm ent), des ign applicat ion s, and logi sti cs purpo ses.
6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-
prepared specification or drawing.
6.3 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for
the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.
6.4 Record of users. Military and industrial users shall inform DLA Land and Maritime when a system application requires
configuration control and the applicable SMD to that system. DLA Land and Maritime will maintain a record of users and this
list will be used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronics
devices (FSC 5962) sho uld co ntact DLA Land and Maritime -VA, telephone (614) 692-8108.
6.5 Comments. Comments on this drawing should be directed to DLA Land and Maritime -VA, Columbus, Ohio 43218-
3990, or telephone (614) 692-0540.
6.6 Approv ed sour ce s of supp ly . Approved sources of supply are listed in MIL-HDBK-103 and QML-38535. The vendors
listed in MIL-HDBK-103 and QML-38535 have agreed to this drawing and a certificate of compliance (see 3.6 herein) has been
submitted to and accepted by DLA Land and Maritime -VA.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-87675
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
G SHEET 12
DSCC FORM 2234
APR 97
STANDARD MICROCIRCUIT DRAWING BULLETIN
DATE: 14-12-04
Approved sources of supply for SMD 5962-87675 are listed below for immediate acquisition information only and
shall be added to MIL-HDBK-103 and QML-38535 during the next revision. MIL-HDBK-103 and QM L-38535 will be
revised to include the add it io n or deletion of sources. The vendors listed below have agreed to this drawing and a
certificate of compliance has been submitted to and accepted by DLA Land and Maritime -VA. This information
bulletin is superseded by the next dated revision of MIL-HDBK-103 and QML-38535. DLA Land and M aritim e
maintains an online database of all current sources of supply at http://www.landandmaritime.dla.mil/Programs/Smcr/.
Standard
microcircuit drawing
PIN 1/
Vendor
CAGE
number
Vendor
similar
PIN 2/
Reference
mi litary specification
PIN
5962-8767501TA
3/
OM3910NT/883B
---
U3158
IP150G-DESC
---
3/
UC150G/883B
---
5962-8767501UA
3/
OM3910ST/883B
---
U3158
IP150IG-DESC
---
3/
UC150IG/883B
---
5962-8767501XA
3/
LM150K/883
M38510/11705BYA
U3158
IP150K-DESC
---
3/
LM150K/883B
---
3/
SG150K/883B
---
3/
UC150K/883B
---
5962-8767501YA
3/
OM3910SRM/883B
---
5962-8767501ZA
3/
OM3910N5M/883B
---
5962-8767502TA
3/
OM3911NT/883B
---
U3158
IP150AG-DESC
---
3/
UC150AG/883B
---
1 of 2
STANDARD MICROCIRCUIT DRAWING BULLETIN - Continued
DATE: 14-12-04
Standard
microcircuit drawing
PIN 1/
Vendor
CAGE
number
Vendor
similar
PIN 2/
Reference
mi litary specification
PIN
5962-8767502UA
3/
OM3911ST/883B
---
U3158
IP150AIG-DESC
---
3/
UC150AIG/883B
---
3/
OM7604STM
---
5962-8767502XA
U3158
IP150AK-DESC
----
3/
LM150AK/883B
----
3/
SG150AK/883B
----
3/
UC150AK/883B
----
5962R8767502UA
3/
OMR3911STM/883B
----
1/ The lead finish shown for each PIN representing a hermetic package is the most
readily available from the manufacturer listed for that part. If the desired lead
finish is not listed contact the vendor to determine its availability.
2/ Caution. Do not use this number for item acquisition. Items acquired to this
number may not satisfy the performance requirements of this drawing.
3/ Not available from an approved source of supply.
Vendor CAGE Vendor name
number and address
U3158 SEMELAB PLC
Coventry Road, Lutterworth,
Leicestershire LE174JB
United Kingdom
The information contained herein is disseminated for convenience only and the
Government as su mes no liability whatsoev er for any inac cur acie s in the
information bulletin.
2 of 2