MPB125 Multiple-Output AC-DC Series Data Sheet
OCT 24, 2005 revised to JUN 05, 2006 Page 1 of 9 www.power-one.com
Multiple Output Model Selection
MODEL
OUTPUT MAXIMUM OUTPUT TOTAL RIPPLE & NOISE 1
REGULATION RANGE
VOLTAGE CURRENT (AMPS), REGULATION % pk-pk
(VOLTS) 130 LFM %
MPB125-2003 2+3.3V 30A ±3% 1% 3.20V to 3.40V
+12V 0.5A ±5% 1% 11.80V to 12.60V
MPB125-2005 3, 4 +5V 25A ±3% 1% 4.85V to 5.15V
+12V 0.5A ±5% 1% 10.80V to 12.60V
MPB125-2012 3, 4, 5 +12V 10.5A ±3% 1% 11.64V to 12.36V
12V 0.5A ±5% 1% 11.40V to 12.60V
MPB125-2015 3, 4, 5 +15V 8.3A ±3% 1% 14.54V to 15.45V
12V 0.5A ±5% 1% 11.40V to 12.60V
MPB125-2024 3, 4, 5 +24V 5.2A ±3% 1% 23.28V to 24.72V
12V 0.5A ±5% 1% 11.40V to 12.60V
MPB125-2048 3, 4, 5 +48V 2.6A ±3% 1% 46.56V to 49.44V
12V 0.5A ±5% 1% 11.40V to 12.60V
MPB125-3000 6+5V 16.5A ±4% 1% 84.85V to 5.25V
+12V 5A/9Apk ±5% 1% 11.40V to 12.60V
-12V 0.5A ±5% 1% -11.40V to -12.60V
MPB125-4250 6
+2.5V 12A 7±3% 2% 2.42V to 2.58V
+5V 15A 7±4% 1% 84.85V to 5.25V
+12V 5A/9Apk ±5% 1% 11.40V to 12.60V
-12V 0.5A ±5% 1% -11.40V to -12.60V
MPB125-4350 6
+3.3V 10A 7±3% 1.5% 3.20V to 3.40V
+5V 15A 7±4% 1% 84.85V to 5.25V
+12V 5A/9Apk ±5% 1% 11.40V to 12.60V
-12V 0.5A ±5% 1% -11.40V to -12.60V
NOTES: 1Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
2For MPB125-2003 and -2003D, a minimum airflow of 10 CFM is required to provide the maximum current of 30A on V1.
V1 current can be as high as 25A with a minimum airflow of 5 CFM.
3Maximum forced-air output power is 125 watts with 5 CFM airflow.
4Maximum convection output power is 70 watts.
5V2 is isolated from V1 and can be used as a negative or positive output.
612V output’s peak load maximum duration is 30 seconds. Average current must not exceed 5A.
7Maximum power of 80 watts from V1 + V2 with 5 CFM forced-air cooling. See Application Note #M3 for details.
8For loads less than 10 watts on V1 + V2 + V3, ripple and noise on the +5V output is Max. 2% peak-to-peak.
• RoHS lead free and lead-solder-exempt products are available
• High power density in an industry-standard 3" x 5" footprint
• Power Factor Correction (PFC) meets EN61000-3-2
• Main output remote sense
• Power Good signals
• CE marked to Low Voltage Directive
• Input transient & ESD compliance to
EN61000-4-2/-3/-4/-5
• MTBF In excess of 1M hours based upon field data
• Optional remote on/off with 5V standby
(See page 4 for ordering information)
Features
The MPB125 Series incorporates patented high efficiency circuitry, high power density and active Power Factor Correction (PFC)
to meet the requirements of networking and data communications systems, as well as commercial and industrial configurations.
Dual output units deliver a regulated main output plus a second 12V output for fans or other system functions. Multiple output models
provide tightly regulated DC power in a variety of configurations. The MPB125 is rated for convection as well as forced-air cooling.
Full output power is available with as few as 5 Cubic Feet per Minute (CFM) forced-air cooling with the exception of the MPB125-
2003 and -2003D which need only 10 CFM for full power. Optional remote on/off with st andby power is also provided (see Options).
The MPB125 product line is approved to the latest international regulatory standards, and displays the CE Mark.
Description