FEATURES BENEFITS
HOW TO ORDER
ST S
ERIES
PRESSURE
TRANSDUCER
High value and outstanding performance Excellent OEM value
Amplified outputs Eliminates cost of external amplifiers
Reverse polarity protection Not damaged by reversed excitation
Less than 500 microseconds response time Accurate high speed measurements
Exceeds CE Heavy Industrial EMC
APPLICATIONS
PNEUMATIC
EQUIPMENT
AIR
COMPRESSORS
AIR FILTRATION
MONITORING
INDUSTRIAL
CONTROLS
* The character R replaces the decimal point in fractional pressure ranges.
** Vacuum for 015 pressure range, full scale output ST-14.7 PSI.
Note: Not all combinations are available. Minimum quantity orders apply. Contact the factory for more details.
MODEL ST • OEM PRESSURE TRANSDUCER
The Model ST pressure transducer combines
Honeywell's proven silicon pressure sensing with
the latest in ASIC technology in a rugged,
industrial package. High value, coupled with
outstanding performance, make this an ideal
transducer for industrial control applications such
as air com-pressors and pneumatic equipment.
Temperature compensated, calibrated, and
amplified, the ST has pressure ranges from 0-5
to 0-250 PSI.
The ST offers three standard output options
for user flexibility, which are as follows: a 0.50
to 4.50 Vdc ratiometric output from 5 Vdc
excitation, a 0.50 to 4.50 Vdc regulated output
from 7 to 35 Vdc excitation, or a 4-20 mA output
from 9.5 - 35 Vdc. TheST transducer delivers
±1.0% full scale accuracy (BFSL) over a wide
temperature range of -40° to 100°C and utilizes
a proven industry standard connector for high
reliability.
Model
Range
Unit
Output
Termination
Port
Material
Pressure
Connection
ST 100 P G 1 S P G F
005 100
010 150
015 200
025 250
050
PSI
P = PSI B = BAR
G = 4-20 mA
R = 0.5 - 4.5 VDC Regulated
C = 0.5 - 4.5 VDC Ratiometric
P = Packard
S = Stainless Steel
B = Brass
1 = 1/8-27 NPT
2 = 1/4-18 NPT
6 = G1/4-18 BSP
Reference
G = Gage (PSIG)
V = Vacuum**
0R4 2R5 006
0R6 001 010
1R6 004 016
BAR
Internal
Seal Material
F = Fluorosilicone
www.honeywell.com/sensing/
ST S
ERIES
PRESSURE
TRANSDUCER
TECHNICAL SPECIFICATIONS
Sensing and Control
Honeywell
100 Discov ery Way
Acton, MA 01720 USA
T el: (877) 384-1300; Fax: (978) 263-0630
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local
sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell
will repair or replace without charge those items it finds defective. The foregoing is Buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of merchantability and fitness for a particular purpose.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer
to determine the suitability of the product in the application.
Item # 1122300 M.G. 05/02 Rev. B
* 1/4-18 NPT and G1/4-18 BSP configurations are both optional.
Contact the factory to discuss other pressure port options.
RANGES*
5, 10, 15, 25, 50, 100, 150, 200, 250 psig*
0.4, 0.6, 1.0, 1.6 , 2.5, 4.0, 6.0, 10.0, 16.0 bar
PHYSICAL
Proof Pressure 2 X rated range
Burst Pressure 150 psi (10 bar), 3 X rated range
200 psi (16 bar), 2 X rated range
Material in Contact 300 Series SS or brass,
With Media internal seal, silicon, polyetherimide
Weight 2.0 oz (57 gm)
ENVIRONMENTAL*
Shock 50 g’s peak (5 ms)
Vibration Figure 514.2-5, Curve AK, Table 514.2-V, Random
Vibration Test (Overall g rms = 20.7 minimum)
ELECTRICAL* Voltage Current
Zero Output 0.5 Vdc 4.0 mA
Full Scale Output* 4.0 Vdc (0.50-4.50 Vdc) 16 mA (4-20 mA)
Excitation
Ratiomentric 5 Vdc ±250 mV (7.0 Vdc max.) 9.5-35 Vdc
Regulated 7 - 35 Vdc
Supply Current 5.0 mA typical N/A
(7.0 mA max.)
Source (nominal) 2.0 mA N/A
Sink (nominal) 20 µA @ zero output N/A
Supply Rejection Ratio 90 db
Output Impedance 25 W max. N/A
PERFORMANCE*
Response Time < 500 microseconds
EMI/RFI Exceeds CE heavy industrial
(30v/m radiated 150kHz-1gHz)
Electrical Connection Packard Metri-Pack™
Packard Metri-Pack connector requires
seperate Packard #12065287 mating connector
Accuracy ±1.0% F.S.O. best fit straight line,
Includes: non-linearity, hysteresis,
non-repeatability. Thermal errors are not included.
Total Error Band ±2% F.S.O. Includes: zero offset error,
span error, thermal effect on zero and thermal effect
on span, non-linearity, hysteresis, non-repeatability
Compensated Operating and -40° to 100°C
Storage Temperature Range (-40° to 212°F)
NOTE: All specifications are measured at 25
°
C (77
°
F) and at rated excitation
unless otherwise specified.
NOTE: Meets IEC-68-2 or MIL-STD 810C.
NOTE: Contact the factory to discuss other pressure ranges.
PIN AND WIRE CODES
sniPegatloVtnerruC
anoitaticxE+noitaticxE+
btuptuOnoitaticxE-
cnommoCC/N
DIMENSIONS
xx.xx = inches
(xx.x) = mm
(40)
1.58
(19)
0.73 (22)
0.85
1/8-27 NPT*
1-1/16 (27) HEX
(27)
1.06
(15)
0.60
a
c
b
Not Intended for
Customer use