DF005SA thru DF10SA
Document Number 88574
12-Jul-05
Vishay General Semiconductor
www.vishay.com
1
Case Style DFS
~
~
~
~
New Product
Miniature Glass Passivated Single-Phase
Surface Mount Bridge Rectifiers
Major Ratings and Characteristics
IF(AV) 1 A
VRRM 50 V to 1000 V
IFSM 30 A
IR5 µA
VF1.1 V
Tj max. 150 °C
Features
UL Recognition, file number E54214
Ideal for automated placement
Middle surge current capability
Meets MSL level 1, per J-STD-020C
Solder Dip 260 °C, 40 seconds
Typical Applications
General purpose use in ac-to-dc bridge full wave rec-
tification for SMPS, Lighting Ballaster, Adapter, Bat-
tery Charger, Home Appliances, Office Equipment,
and Telecommunication applications
Mechanical Data
Case: DFS
Epoxy meets UL-94V-0 Flammability rating
Terminals: Matte tin plated (E3 Suffix) leads, solder-
able per J-STD-002B and JESD22-B102D
Polarity: As marked on body
Maximum Ratings
(TA = 25 °C unless otherwise noted)
Parameter Symbol DF
005SA
DF
01SA
DF
02SA
DF
04SA
DF
06SA
DF
08SA
DF
10SA
Unit
Device marking code DFA
005S
DFA
01S
DFA
02S
DFA
04S
DFA
06S
DFA
08S
DFA
10S
Maximum repetitive peak reverse voltage VRRM 50 100 200 400 600 800 1000 V
Maximum RMS voltage VRMS 35 70 140 280 420 560 700 V
Maximum DC blocking voltage VDC 50 100 200 400 600 800 1000 V
Maximum average forward output rectified current
at TA = 40 °C(2)
IF(AV) 1.0 A
Peak forward surge current single half sine-wave
superimposed on rated load
IFSM 30 A
Rating for fusing (t < 8.3 ms) I2t 4.5 A2sec
Operating junction and storage temperature range TJ, TSTG - 55 to + 150 °C
www.vishay.com
2
Document Number 88574
12-Jul-05
DF005SA thru DF10SA
Vishay General Semiconductor
Electrical Characteristics
(TA = 25 °C unless otherwise noted)
Thermal Characteristics
(TA = 25 °C unless otherwise noted)
Notes:
(1) Measured at 1.0 MHz and applied reverse voltage of 4.0 Volts
(2) Units mounted on P.C.B. with 0.51 x 0.51" (13 x 13 mm) copper pads
Ratings and Characteristics Curves
(TA = 25 °C unless otherwise noted)
Parameter Test condition Symbol DF
005SA
DF
01SA
DF
02SA
DF
04SA
DF
06SA
DF
08SA
DF
10SA
Unit
Max. instantaneous forward
voltage drop per leg
at 1.0 A VF 1.1 V
Maximum DC reverse current at
rated DC blocking voltage per leg
TA = 25 °C
TA = 125 °C
IR 5.0
500
µA
Typical junction capacitance per
leg (1)
CJ 25 pF
Parameter Symbol DF
005SA
DF
01SA
DF
02SA
DF
04SA
DF
06SA
DF
08SA
DF
10SA
Unit
Typical thermal resistance per leg(2) RθJA
RθJL
40
15
°C/W
Figure 1. Derating Curve Output Rectified Current
20 40 60 80 100 120 140 160
0
0.5
1.0
60 HZ
Resistive or
Inductive Load
P.C.B mounted on
0.51 x 0.51" (13 x 13 mm)
Copper pads
Average Forward Output Current (A)
Ambient Temperature ( °C)
Figure 2. Maximum Non-Repetitive Peak Forward Surge Current
Per Leg
110 100
0
5
10
15
20
25
30
1.0 Cycle
Peak Forward Surge Current (A)
Number of Cycles at 60 Hz
TJ= 150 °C
Single Sine-Wave
DF005SA thru DF10SA
Document Number 88574
12-Jul-05
Vishay General Semiconductor
www.vishay.com
3
Package outline dimensions in inches (millimeters)
Figure 3. Typical Forward Characteristics Per Leg
Figure 4. Typical Reverse Leakage Characteristics Per Leg
0.4 0.6 0.8 1.0 1.2 1.4
0.01
0.1
1
10
Instantaneous Forward Current (A)
Instantaneous Forward Voltage (V)
TJ=25 °C
Pulse width = 300 μs
1% Duty Cycle
020 40 60 80 100
0.01
0.1
1
10
100
Instantaneous Reverse Current (μA)
Percent of Rated Peak Reverse Voltage (V)
TJ= 125 °C
TJ=50°C
Figure 5. Typical Junction Capacitance Per Leg
Figure 6. Typical Transient Thermal Impedance
110 100
1
10
100
Junction Capacitance (pF)
Reverse Voltage (V)
TJ=25 °C
f = 1.0 MHz
Vsig = 50mVp-p
0.01 0.1 110 100
0.1
1
10
100
Transient Thermal Impedance ( °C/W)
t, Heating Time (sec.)
Mounting Pad La yout
0.255 (6.5)
0.245 (6.2)
0.013 (0.330)
0.009 (0.241)
0.060 (1.524)
0.040 (1.016)
0.404 (10.3)
0.013 (0.330)
0.003 (0.076)
0.047 (1.20)
0.040 (1.02)
0.205 (5.2)
0.195 (5.0)
0.335 (8.51)
0.320 (8.13)
0.130 (3.3)
0.120 (3.05)
45
o
0.386 (9.80)
Case Style DFS
0.404 Max.
(10.26 Max.)
0.205 (5.2)
0.195 (5.0)
0.047 Min.
(1.20 Min.)
0.060 Min.
(1.52 Min.)
Legal Disclaimer Notice
Vishay
Document Number: 91000 www.vishay.com
Revision: 08-Apr-05 1
Notice
Specifications of the products displayed herein are subject to change without notice. Vishay Intertechnology, Inc.,
or anyone on its behalf, assumes no responsibility or liability for any errors or inaccuracies.
Information contained herein is intended to provide a product description only. No license, express or implied, by
estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Vishay's
terms and conditions of sale for such products, Vishay assumes no liability whatsoever, and disclaims any express
or implied warranty, relating to sale and/or use of Vishay products including liability or warranties relating to fitness
for a particular purpose, merchantability, or infringement of any patent, copyright, or other intellectual property right.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications.
Customers using or selling these products for use in such applications do so at their own risk and agree to fully
indemnify Vishay for any damages resulting from such improper use or sale.