Copyright ©2012 Zilog®, Inc. All rights reserved.
www.zilog.com
Introduction
Zilog’s Ethernet Smart Cable, part number ZENETSC0100ZACG, allows you to connect
Z8 Encore!®, Z8 Encore! XP®, ZNEO and eZ8 0A c cla im !® development boards to a
Zilog Developer Studio II (ZDS II) host system using an Ethernet connection.
This user manual provides instructions for installing the Ethernet Smart Cable hardware.
Instructions are also provided for Ethernet-equipped host PCs that are not network-con-
nected. After the Ethernet Smart Cable is connected, proceed with debugging as described
in the documentation specific to your development kit.
Kit Contents
To determine the contents of your kit, refer to the Ethernet Smart Cable Packing List
(PAK0019), a paper insert included with your kit.
Software and Hardware Requirements
The requirements for using the Ethernet Smart Cable are:
A host PC with ZDS II v4.10.0 or later for Z8 Encore!, eZ80Acclaim!, or ZNEO. To
determine ZDS II requirements for your host system, refer to the quick start guide for
your specific development kit. The latest version of ZDS II is availa ble as a free down -
load from the Zilog Store.
An available 10/100 Mbps Ethernet connection.
If you are using ZDS II – eZ80Acclaim! versions earlier than 4.10.0, see the
Using the Ethernet Smart Cable on ZDS II – eZ80Acclaim! Versions Earlier
than 4.10.0 section on page 11.
Note:
Ethernet Smart Cable
User Manual UM020705-1012
Ethernet Smart Cable
User Manual
UM020705-1012 Page 2 of 13
Supported Target Environments
The supported target environments are described in the following table.
Installing the Ethernet Smart Cable
The Ethernet Smart Cable is optimized for use on an Et hernet network in which a dynamic
host configuration protocol (DHCP) server assigns IP addresses. The following sections
provide instructions for connecting the Ethernet Smart Cable to a DHCP-based network,
or directly to an Ethernet-equipped host PC.
The Ethernet Smart Cable’s factory default settings include:
DHCP enabled
IP address: 192.168.1.50 (this address will be different if a DHCP server is available
to assign an address)
Subnet mask: 255.255.255.0
Gateway: 192.168.1.254
No password required
If you need to ch ange th e cable’s factory default settings, fol low the steps described in the
Changing the Default Settings of the Ethernet Smart Cable section on page 8.
When a DHCP server is unavailable, the Ethernet Smart Cable defaults to
using IP address 192.168.1.50. If your network uses static IP addresses on a
different subnet, connect the Ethernet Smart Cable to a stand-alone PC con-
figured as described in the next section.
Development Board
System Clock Power Supply
Current*Minimum Maximum Minimum Maximum
Z8 Encore! 32 kHz 20 MHz 2.7 V 3.6 V 2 mA
ZNEO 10 kHz 20 MHz 2.7 V 3.6 V 2 mA
eZ80Acclaim! 5 MHz 50 MHz 3.0 V 3.6 V 2 mA
Note: *Add this Ethernet Smart Cable current as a requirement for your target’s power supply.
Note:
Ethernet Smart Cable
User Manual
UM020705-1012 Page 3 of 13
Connecting the Ethernet Smart Cable to a DHCP-Based
Network
The following considerations must be determined prior to connecting the Ethernet Smart
Cable to a DHCP-based network:
An active Ethernet connection must be available, such as from an Ethernet hub
A standard CAT-5 Ethernet cable must be available
Observe the following steps to connect the Ethernet Smart Cable:
1. Connect the Ethernet Smart Cable to an Ethernet connection.
2. Connect the 5 V DC power supply to th e Et hernet Smart Cable power connector. As a
result, the green PWR and RUN LEDs will illuminate. The green link LED on the
Ethernet Smart Cable RJ-45 connector illuminates, as shown in Figure 1, indicating a
live Ethernet connec tio n. Th e green activity LED on the Ethernet Smart Cable RJ-45
connector flickers, indicating network activity.
Figure 1. Ethernet Smart Cable, Front View and Rear View
DBG Connector
RUN LED
PWR LED
Ethernet Connector
5 VDC Power In
Activity LED Link LED
Ethernet Smart Cable
User Manual
UM020705-1012 Page 4 of 13
3. Launch ZDS II.
4. Navigate via the File menu in ZDS II to open one of the projects listed in the samples
directory of your ZDS II installation.
5. Select Project Settings to display the Project Settings dialog.
6. Select the Debugger tab.
7. From the Debug Tool drop-down menu, select EthernetSmartCable.
8. Click the Setup button. Your Ethernet Smart Cable will be listed in the Smart Cables
Available list. Select the checkbox for your Ethernet Smart Cable, then click the OK
button.
If you have more than one Ethernet Smart Cable, you can uniquely identify
them by comparing the MAC address listed in the Smart Cables Available
list with the label on the bottom of the Ethernet Smart Cable.
9. Click the OK button in the Project Settings window. Your project is now configured
to run with the newly installed Ethernet Smart Cable.
10. Connect the target board to the Ethernet Smart Cable as described in the Connecting to
the Target Board section on page 11.
Connecting the Ethernet Smart Cable Directly to a Host PC
When using a host PC that is not network-connected, configure the PC as follows to con-
nect it to the Ethernet Smart Cable.
The following instructions are designed for use on a MS Windows XP plat-
form. If your Windows operating system is different, refer to MS Windows
OS online help for details.
Observe the following steps to connect the Ethernet Smart Cable to a host PC:
1. Power on your host PC before proceeding.
Note:
Note:
Ethernet Smart Cable
User Manual
UM020705-1012 Page 5 of 13
2. Use the Ethernet crossover cable supplied with the Ethernet Smart Cable to connect
the Ethernet Smart Cable to the host PC’s Ethernet port.
3. Connect the 5 V DC power supply to th e Et hernet Smart Cable power connector. As a
result, the green PWR and RUN LEDs will illuminate. The green link LED on the
Ethernet Smart Cable’s RJ-45 connector illuminates (see Figure 1 on page 3 ), indic at-
ing a live Ethernet connection. The green activity LED on the Ethernet Smart Cable
RJ-45 connector flickers, indicating network activity.
4. On the host PC, open the Windows Control Panel and double-click the Networ k and
Internet Connections icon. The Network Connections dialog box will appear, as
shown in Figure 2.
Figure 2. The Network Dialog
Ethernet Smart Cable
User Manual
UM020705-1012 Page 6 of 13
5. In the panel labeled LAN or High-Speed Internet, double-click the Local Area Con-
nection icon. The Local Area Connection Status dialog box will appear, as shown
in Figure 3.
6. In the Local Area Connection Status dialog box, click the Properties button. The
Local Area Connection Properties dialog box will appear, as shown in Figure 4.
Figure 3. The Local Area Connection Stat us Dialog
Ethernet Smart Cable
User Manual
UM020705-1012 Page 7 of 13
7. In the panel labeled This connection uses the following items:, select the Internet
Protocol (TCP/IP) item to highlight it, and click the Properties button (see Figu re 4
for an example). The Internet Protocol (TCP/IP) Properties dialog box will appear,
as shown in Figure 5.
Figure 4. The Local Area Connection Properties Dialog
Ethernet Smart Cable
User Manual
UM020705-1012 Page 8 of 13
8. Enter an IP address of 192.168.1.21 and a subnet mask of 255.255.255.0. These
values place the PC on the same network as the Ethernet Smart Cable, and do not con-
flict with the IP address of the Ethernet Smart Cable.
9. Click OK and restart the PC.
The PC is now ready to communicate with Ethernet Smart Cable via the ZDS II software.
The default IP address of the Ethernet Smart Cable unit is 192.168.1.50.
Changing the Default Settings of the Ethernet Smart Cable
The Ethernet Smart Cable is equipped with a web interface that allows you to change its
default settings. To acc ess the Ethernet Smart Cable web interface, you must know the
Figure 5. The Internet Protocol Properties Dialog
Ethernet Smart Cable
User Manual
UM020705-1012 Page 9 of 13
cable’s IP address, which can be obtained from ZDS II in the ZDS II Project Settings win-
dow; see Steps 5 through 9 on page 4) .
Observe the following steps to change the Ethernet Smart Cable’s default settings:
1. Obtain the Ethernet Smart Cable IP address.
2. Open your web browser to the IP address located in Step 1. The Ethernet Smart Cable
home page will appear, as shown in Figure 6. The Settings tab on this page provides
access to the Ethernet Smart Cable’s network settings. The Password tab, shown in
Figure 7, allows you to set a password for Ethernet Smart Cable access.
Figure 6. Ethernet Smart Cable Home Web Page
Ethernet Smart Cable
User Manual
UM020705-1012 Page 10 of 13
3. After the configuration in the Settings tab are changed, click the Submit button. A
message acknowledging that changes have been made will appear beneath the web
page.
4. To make the changes permanent, reboot the Ethernet Smart Cable by pressing the
Reboot button. As a result, the Ethernet Smart Cabl e will reboot. If you have changed
the cable’s IP address, redirect the web browser to point to the new IP address. If the
IP address remains at its previous setting, the Ethernet Smart Cable home page will
appear again, displaying the changes you made.
Restoring the Ethernet Smart Cable Factory Settings
Observe the following steps to restore the Ethernet Smart Cable to its factory settings.
1. Locate the reset switch access hole in the side of the Ethernet Smart Cable housing.
2. Using a straightened p aper clip, press and hold the reset switch for si x seconds. The
Run LED will extinguish while the switch is pressed, and will illuminate again after
the factory settings are restored.
Figure 7. Ethernet Smart Cable Password Web Page
Ethernet Smart Cable
User Manual
UM020705-1012 Page 11 of 13
Connecting to the Target Board
Attach one end of the six-conductor ribbon cable to the Smart Cable six-pin DBG connec-
tor, as shown in Figure 1 on page 3. Attach the free end of the ribbon cable to the connec-
tor on the target board. Ensure that pin 1 on the ribbon cable (indicated by the dark stripe)
is aligned with pin 1 on the target connector. To learn more about connecting the Ethernet
Smart Cable to your target board, refer to the eZ80Acclaim! Design for Debug Technical
Note (TN0035) or the Z8 Encore! Design for Debug Technical Note (TN0036).
Using the Ethernet Smart Cable on ZDS II –
eZ80Acclaim! Versions Earlier than 4.10.0
Observe the following procedure to obtain the IP address of the Ethernet Smart Cable
when configured for DHCP.
1. Download the ESCScan utility installation file from the Zilog Store; simply click the
Downloadable Sof tware category, in which you’ll find ES CScan listed as Product ID
SD0012.
2. Run the installation file to install it to your local drive.
3. Run the escscan.exe application file from the installation directory; it will appear
similar to the example screenshot shown in Figure 8.
Figure 8. escscan.exe Application Screenshot
Ethernet Smart Cable
User Manual
UM020705-1012 Page 12 of 13
4. Note the IP Address. If you have several Ethernet Smart Cables connected to the net-
work, an IP address will be shown for each particular Ethernet Smart Cable’s MAC
address.
5. Press any key to exit the utility.
6. You must use the IP address determined in Step 4 when configuring ZDS II; simply
navigate via ZDS II Project Settings Debugger Configure ZPAK II IP
Address. For more information about this utility, refer to its readme.txt document.
Troubleshooting Tips
If a hardware failure is suspected, contact support.zilog.com for assistanc e. However,
before submitting a problem report to Zilog Customer Support, follow the instructions in
this section.
ZDS II Cannot See the Ethernet Smart Cable
If ZDS II cannot detect the Ethernet Smart Cable, try the following workarounds:
Remove power from the Ethernet Smart Cable, wait five seconds, then reapply power.
Refresh the list of available smart cables. The Ethernet Smart Cable should now
appear.
Verify that the Ethernet cable you are using is the correct type. (If you are connecting
the Ethernet Smart Cable directly to a PC, you must use a crossover cable. Do not use
a crossover cable to connect the Ethernet Smart Cable to a hub or standard Ethernet
connection.)
Verify that UDP port 3000 is open in your local firewall. The ZDS II software uses
UDP port 3000 to search for Ethernet Smart Cable IP addresses and requires access to
that port through your lo cal firewall. After the port is open, ZDS II should then be able
to identify the IP address assigned to the Ethernet Smart Cable by your DHCP server.
Ethernet Smart Cable
User Manual
UM020705-1012 Page 13 of 13
DO NOT USE THIS PRODUCT IN LIFE SUPPORT SYSTEMS.
LIFE SUPPORT POLICY
ZILOG'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPO-
NENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS
PRIOR WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF
ZILOG CORPORATION.
As used herein
Life support devices or systems are devices which (a) are intended for surgical implant
into the body, or (b) support or sustain life and whose failure to perform when properly
used in accordance with instructions for use provided in the labeling can be reasonably
expected to result in a significant injury to the user. A critical component is any compo-
nent in a life support device or system whose failure to perform can be reasonably
expected to cause the failure of the life support device or system or to affect its safety or
effectiveness.
Document Disclaimer
©2012 by Zilog, Inc. All rights reserved. Information in this publication concerning the
devices, applications, or technology described is intended to suggest possible uses and
may be superseded. ZILOG, INC. DOES NOT ASSUME LIABILITY FOR OR PRO-
VIDE A REPRESENTATION OF ACCURACY OF THE INFORMATION, DEVICES,
OR TECHNOLOGY DESCRIBED IN THIS DOCUMENT. ZILOG ALSO DOES NOT
ASSUME LIABILITY FOR INTELLECTUAL PROPERTY INFRINGEMENT
RELATED IN ANY MANNER TO USE OF INFORMATION, DEVICES, OR TECH-
NOLOGY DESCRIBED HEREIN OR OTHERWISE. The information contained within
this document has been verified according to the general principles of electrical and
mechanical en gin ee rin g.
Z8 Encore!, Z8 Encore! XP, ZNEO and eZ80Acclaim! are tradema rks or regis tered trade-
marks of Zilog, Inc. All other prod uct or service names are the property of their respective
owners.
Warning:
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
ZiLOG:
ZUSBOPTSC01ZACG ZENETSC0100ZACG